Teseq Automotive ISO 7637 Transient System Rental

Availability:
In Stock - Order By 3PM Ships Today!

Teseq Automotive Transient System:

  • Includes - NSG 5500PA 5840, & ACC Clamp
  • PA 5480 (Batter Simulators) - 25A & 100A Rentals
  • Transient Generator Based on ISO 7637-2/3 Pulses
  • Complete Syste Includes Laptop with Autostar Software 
  • Current ISO 17025 Cal & 2 Days Free Transit Time

Options/Equipment


Get weekly, two week, and monthly rentals on all products

Got Questions about the equipment? Get technical support

Two FREE days transit time with every rental

Request A Quote

Teseq Automotive Immunity System

Video Guides

Teseq NSG 5500 & PA 5840 - Test System Overview

This video includes the setup of the Teseq automotive transient test system including connections to get the system operational and use of the AutoStar 7 software to modify pulses.

Teseq NSG 5500 / NSG 5600

This video provided by Teseq, the manufacturer of the NSG 5500 test systems, provides system information and a brief overview of capabilities of the control software.

Data SheetUser ManualBrochure - Electrical Disturbances

Overview

The Teseq NSG 5500, PA 5840, and automotive coupling clamp (conducted immunity system) are designed for ISO7637-2 (pulses 1-7) and a variety of manufacturer (OEM) standards. This system is a combination of three different Automotive EMI products providing a complete test system. Each one of the major components can be rented individually, comes with a laptop, and is calibrated to ISO 17025. We offer rentals, as short as a week, providing a cost effective solution for a short term testing need.

Specifications

Common Standards

SAE J1113ISO 7637, ISO 16750GMW3172 and many other car manufacturer standards

MT 5511

Generates ISO 7637 waveforms 1, 2a and 6

Test Voltage

0-600V

Rise Time

1us ,2us, 3us, 60us

Pulse Duration

50us – 400us


Source Impedance

2, 4, 10, 20, 30, 50, 90 Ω 

Pulse Intervals

.2 – 60 seconds

LD 5550

Generates ISO 7637 waveforms 5a, 5b

Test Voltage

20V – 200V

Clamping

10V – 100V

Impedance

.5 – 10 Ω, 30.5 Ω, 40 Ω

Pulse Rise Time

.09 to 10 ms

Pulse Duration

30-1500ms in 1 ms steps

Pulse Repetition

15-600s, pulse repetition depends on pulse energy

Pulse Modes

Single, continuous, programmed t1 to 9,999

FT 5531

Generates ISO 7637 waveforms 3a, 3b

Pulse Amplitude – 150ns pulse

50-800V EUT / 50-600V BNC

Pulse Amplitude – 100ns pulse

50-600V

Impedance

50 Ω

Pulse Rise Time

5 ns

Pulse Width

150 ns / 100 ns

Pulse Frequency

1 – 100 Khz

Burst Interval

0.01 to 99.9 ms

Pulses per burst

1 – 200

Burst Repetition

90 ms – 99.9 s in 10 ms steps

Weight

20kg (44.09lbs)

Dimensions

19”x 13”x20”   48x33x51 cm

Accessories/Packing List

Included with Rental of Teseq NSG 5500 & PA 5840 75/100

NSG 5500

    • Power Cable 
    • Printed Manual
    • Calibration Documentation
    • Laptop with Charger Loaded Autostar 7 Software
    • D Shaped 9 Pin serial Cable CTR 5502-PA
    • NI GPIB to USB converter 
    • 2m GPIB cable
    • Software License
    • Software Autostar 7 on USB

 

PA 5840 75/100
    • PA 5840
    • Key to Start PA 5840
    • Power Supply Cable
    • Interlock Connected to Power Stage 2
    • Cable Control In-Power Stage 1
    • Mains to Control Unit Cable
    • (2 pcs) 600V 32Amp Power cable
    • INA 5232 100A DC Cable 
    • Calibration Documentation.

 

Automotive ACC Clamp
    • ACC Clamp
    • KW 50 Ohm Load
    • Fischer to Fischer Cable
    • Pelican Case

Modules

NSG 5500 Rental System Modules

Module

Description

NSG 5500-1 Mainframe HV Supply, Processor, Power Entry Module, IEEE Interface, CDN 5500 100A coupler, FT 5531 Fast Transient Generator

AutoStar 7

Windows Software Package for NSG 5500

+ ARB Option

Arbitrary waveform generator option for new NSG 5500. Includes 1 ARB 5500 card, ability for an additional 7. Requires Autostar 7.x or higher, not compatible with earlier versions.

MT5511

Plug-in Module for ISO/SAE pulses 1/2/6, GM 7a/7b. Meets ISO 7637-2 & SAE J1113-11 requirements

LD 5550

High energy load dump module includes internal source impedance resistor matrix.

PA 5840-150/200

+60/-10V, 50A Battery Simulator, 3dB bandwidth up to 150kHz. Peak output current 150A, 120/208V 3-phase input (requires ARB 5500 or FG 562x and Autostar Software)

 

Additional Modules

Module

Description

CDN 500 ISO Pulse 3a/3b Coupling Clamp for data lines. Requires 30Ohm termination, INA 5030B recommended.

INA 5530

High power 50 Ohm & 1000 Ohm Verification kit including INA 5530-50 & INA 5530-1k for EFT (pulses 3a/4b) measurement.

INA 5032

High voltage x100 50M Ohm, 7.5pF, 400MHz oscilloscope probe according to ISO 7637-2:2011


PA5840 Rental Systems

Module

Description

PA 5840-75 25Amp programmable power amplifier/battery simulator for use with the NSG5500. Allows for  high bandwidth up to 150 kHz

PA 5840-100

100 Amp programmable power amplifier/battery simulator for use with the NSG5500. Allows for  high bandwidth up to 150 kHz

Standards

Widely Used Standards

This list is a more comprehensive list of all the standards covered with this automotive load dump generator. This is by no means all the standards covered, but the major ones from the largest manufacturers and most widely used standards.

 

  • UN ECE R10 (Automotive)
  • ISO 7637-1
  • ISO 7637-2
  • ISO 7637-3
  • ISO 16750-2
  • JASO D001-94
  • SAE J1113-11
  • SAE J1113-12
  • SAE J1455
  • BMW 600 13.0 (Part 2)
  • BMW GS 95002
  • BMW GS 95003-2
  • BMW GS 95024-2-1
  • Chrysler CS-11809 (2009)
  • Chrylser CS-11979
  • Chrysler DC-11224 Rev.A
  • Chrysler PF-9326
  • DaimlerChrysler DC-10614
  • DaimlerChrysler PF-10540
  • EN 300329
  • EN 300340
  • EN 300342-1
  • EN 301489-1
  • EN 301489-17
  • EN 301489-24
  • EN 301489-7
  • Fiat 9.90110
  • Ford EMC-CS-2009.1
  • Ford ES-XW7T-1A278-AC
  • Ford WDR 00.00EA
  • Freightliner 49-00085
  • GM 9105P
  • GMW 3097
  • GMW 3100
  • GMW 3172
  • Honda 3982Z-SDA-0030
  • Hyundai ES 39110-00
  • Hyundai ES 96100-02
  • IVECO 16-2103
  • Kia/Hyundai ES 95400-10
  • Mack Trucks 606GS15
  • MAN 3285
  • Mazda MES PW 67600
  • Mercedes MBN 10284-2
  • Mercedes AV EMV
  • Mercedes-Benz A 211 000 42 99
  • Mercedes MBN 22100-2
  • Mitsubishi ES-X82010
  • MW 3097
  • Nissan 28400 NDS 03
  • Nissan 28400 NDS 05
  • Nissan 28400 NDS 07
  • Nissan 28401 NDS 02
  • Piaggio 7431
  • Porsche
  • PSA B21 7090
  • PSA B21 7110
  • Renault 36.00.400/B
  • Renault 36.00.400/C
  • Renault 36.00.808/--D
  • Renault 36.00.808/--E
  • Renault 36.00.808/--F
  • Renault 36.00.808/--G
  • Renault 36-00.808/--H
  • Renault 36.00.808/--J
  • Renault 36.00.808/--K
  • Renault 36.00.808/--L
  • SA B21 7110
  • Scania TB1400
  • Scania TB1700
  • Smart DE1005B
  • Toyota TSC3500G
  • Toyota TSC3590G
  • Toyota TSC6203G
  • Toyota TSC7001G
  • Toyota TSC7034G
  • Volvo EMC Requirements
  • VW TL 801 01
  • VW TL 820 66
  • VW TL 821 66
  • VW TL 823 66
  • VW TL 824 66