Overview
EMTest CNV504N1.3 coupling/decoupling networks for unshielded unsymmetrical interconnection signal/data lines. Surge pulses or Ringwave pulses are applied to unshielded unsymmetrical interconnected lines by means of standalone coupling/decoupling networks for 4 signal/data lines. CNV 504 N1.3 combines three different applications; coupling of Surge pulse via capacitor or gas arrestor and coupling of Ringwave pulses via capacitor being required by EN IEC 61000-4-5 and/or EN IEC 61000-4-12.
The required coupling mode, Differential or Common, can easily be selected by means of a simple jumper. In accordance with EN IEC 61000-4-5 and EN IEC 61000-4-12 pulses are coupled via different coupling elements such as capacitors or gas arrestors depending on the characteristics of the line signals.
Data SheetUser ManualSpecifications
Common Standards |
EN IEC 61000-4-5 & EN IEC 61000-4-12 |
No. of Lines |
4 Unshielded unsymmetrical interconnection lines |
Test Voltage Max |
Up to 4kV |
Line Voltage Max. |
250 VAC, 300 VDC |
Coupling/Decoupling |
4 kV coupling/ decoupling network line current 4 A, intermittent 5 A |
Decoupling Inductance |
20 mH, each line |
Surge coupling |
per EN IEC 61000-4-5 Ed. 3, -0.5 µF capacitor via 40 ohm |
Ringwave coupling |
per EN IEC 61000-4-12 Ed. 2, -3.3 µF capacitor |
Dimension and Weight |
330 x 230 x 112 mm, 9.75KG 13 x 9.1 x 4.4 in, 21.5LBS |