IMU4000 accessories

Teseq EFT CCL

Coupling Clamp (CCL) Features 

      • New design, Includes Safety Cover & Interlock
      • ISO 17025 Calibration & 2 Days Free Transit
      • Compliant IEC 61000-4-4 Ed.2 & Ed.3
      • Can Work With Many Immunity Generators!
      • Replaces CDN 8014 and CDN 8015
      • Turnkey Solution - Arrives Ready for Testing!

Overview

The Teseq CDN3425 (Teseq CCL) main purpose is to couple Burst/EFT pulses to data lines. It can also be used to couple to mains lines where no CDN is available; for example, high current lines >200 A. This coupling decoupling network (CDN) capacitive coupling clamp (CCL) comes with an ISO 17025 accredited calibration and works with a many conducted immunity generators

The new design is fully compliant with the specifications of IEC 61000-4-4 Ed 2.0 2004, as well as with the draft of EN/IEC 61000-4-4 Ed 3.0 to be published in 2012. This model also replaces earlier models CDN 8014 and CDN 8015.The coupling capacitance between the coupling clamp and the cable laid in it depends on the cable characteristics. 

Keytek EFT CCL

In Stock

Coupling Clamp (CCL) Features 

      • Thermo Keytek Design Includes Cords
      • ISO 17025 Calibration & 2 Days Free Transit
      • Compliant IEC 61000-4-4 Ed.2 & Ed.3
      • Can Work With Many Immunity Generators!
      • Turnkey Solution - Arrives Ready for Testing!

Overview

The capacitive coupling clamp by Thermo-Keytek is designed for EFT pulses on I/O lines or data lines per EN/IEC 61000-4-4. This equipment is fully compliant with the specifications of IEC 61000-4-4 Ed 2.0 2004, as well as with the draft of EN/IEC 61000-4-4 Ed 3.0 published in 2012. These testing accessories have the capabilities to work with a variety of conducted immunity generators from many manufacturers, making it an ideal solution. 

Current Monitoring Probe

In Stock

Current Monitoring Features 

      • Maximum Peak Current - 5000 Amperes
      • ISO 17025 Accredited Calibration included
      • Pearson Electronics Monitor Model 110
      • Useable rise time 20 Nanoseconds
      • Output Resistance 50 Ohms
      • Turnkey Solution - Arrives Ready for Testing!

Overview

Pearson Model 110 Current Probe.  Donut shaped for current monitoring up to 5000 Amps .1 Volts per Amp. attenuation.

Waveform Verification Devices

Burst/EFT Pulse Verification Kit 

      • Verification/calibration kit for IEC/EN 61000-4-4
      • For peak voltages up to 8.8 kV 
      • INA 265B: 50 Ω termination
      • INA 266A: 1 kΩ termination
      • Turnkey Solution - Arrives Ready for Testing!

Overview

The Teseq CAS3025 burst/EFT pulse verification kit has been specially designed to comply with the new requirements of IEC/EN 61000-4-4:2004 to enable EMC engineers to verify their burst/EFT test generators periodically. Many EMC standards call for a verification of the test equipment before and after every test session. If the verification shows differing results, no valid test results can be assumed and the test equipment has to be re-calibrated.

HV Monitoring Probe

Differential Probe Features 

      • Selectable attenuation settings of 100x/1000x
      • 70 MHz bandwidth (-3 dB)
      • Power and over-range indicators
      • Up to ±7 kV differential and common mode
      • High CMRR

Overview

Differential probes allow safe, accurate measurement between two voltage points where neither point is referenced to ground. The CT3681 and CT3683 both offer a 70 MHz bandwidth and can test up to ±7 kV (DC + AC peak). Compatible with oscilloscopes from all major manufacturers, the probes can be battery operated, powered by a universal adapter (optional), or powered by USB power lead (optional) if the oscilloscope is so equipped

6kV High Voltage Probes

In Stock

6kV HV Probe Features

      • 6kV High Voltage Probes - Ideal for EMI
      • 200:1 Attenuation; Low EMI sensitivity
      • BNC Connection to Oscilloscope
      • Convenient to use & Self Interlock system 
      • Arrives Ready for Testing!

Overview

The differential oscilloscope probes normally used for monitoring high voltage surges and transients are generally large and cumbersome (because they are designed for use to 40 kV), unduly sensitive to noise, and difficult to maintain in close compensation adjustment. KeyTek'sModel PK 1001Dis a relatively small, lightweight probe designed to provide accurate transmission of peak surge waves to 6 kV,with fronts from 10 ns to 1.2.

Its relatively low input impedance provides low sensitivity to noise. Quick and convenient to use, the Model PK 1001 requires no ground at the probe tip, and no compensation adjustments. An auxiliary interlock unit ensures a high degree of operator safety during probe use.

10kV High Voltage Probes

In Stock

10kV HV Probe Features

      • 10kV High Voltage Probes - Ideal for EMI
      • 200:1 Attenuation; Low EMI sensitivity
      • BNC Connection to Oscilloscope
      • Convenient to use & Self Interlock system 
      • Arrives Ready for Testing!

Overview

The differential oscilloscope probes normally used for monitoring high voltage surges and transients are generally large and cumbersome (because they are designed for use to 40 kV), unduly sensitive to noise, and difficult to maintain in close compensation adjustment. KeyTek'sModel PK 1001Dis a relatively small, lightweight probe designed to provide accurate transmission of peak surge waves to 6 kV,with fronts from 10 ns to 1.2.

Its relatively low input impedance provides low sensitivity to noise. Quick and convenient to use, the Model PK 1001 requires no ground at the probe tip, and no compensation adjustments. An auxiliary interlock unit ensures a high degree of operator safety during probe use.