Fischer F-120-9A - Rent 230MHz Current Injection Probe

Availability:
In Stock - Order By 3PM Ships Today!

Fischer Current Injection Probe:

  • 10 kHz to 230 MHz Probe, 125CW Maximum
  • Rented in IEC 61000-4-6 Accesory Package
  • Ideal for Bulk Current Injection (BCI) Test Method
  • FCC-MPCF-3 Calibration Fixture Included

Get weekly, two week, and monthly rentals on all products

Got Questions about the equipment? Get technical support

Two FREE days transit time with every rental

Request A Quote

Description

The F120-9 A (F120 9) is a Fischer Custom Communications bulk current injection probe for testing products for immunity to conducted RF per IEC 61000-4-6. The F-120-9A has been designed to extend the use of conducted immunity testing over the bandwidth of 10 kHz – 230 MHz. The useable frequency range is 10 kHz - 230 MHz with an insertion loss of less than 8 dB between 150 kHz – 200 MHz. The input power rating is 100 watts for 30 minutes.

F120-9A Fischer - Data Sheet

Specifications

Common Standards

EN IEC 61000-4-6

Input Power Rating

100W

Frequency

10kHz – 230MHz

Insertion Loss

<8dB (150kHz – 200MHz)

Inner Diameter

40mm

Outer Diameter

127mm

Height

134mm