Teseq ProfLine 2105 - 5 kVA Harmonics & Flicker Test System

Teseq ProfLine System:

  • Designed for Flicker & Harmonics Testing
  • Complete test system for IEC 61000-3-2 and 3-3
  • Designed for Single Phase DUT/EUT up to 16 Amps
  • Simulated Flicker Impedance, Cost Effective Solution
  • Current ISO 17025 Cal & 2 Days Free Transit Time

Get weekly, two week, and monthly rentals on all products

Got Questions about the equipment? Get technical support

Two FREE days transit time with every rental

Request A Quote

ProfLine 2105 Related Equipment

Description

Overview

The Teseq Profline2105 by Teseq has a stable and programmable 5KVA power supply and line conditioner (Cal Inst 5000ix) used for measuring single phase harmonics (EN/IEC 61000-3-2) and flicker (EN/IEC 61000-3-3) testing. The NSG1007 power supply is included in the Profline2105 rental. An A2LA accredited calibration is included in the EMC rental equipment price. 

This Harmonics and Flicker Emissions Tester has a fully programmable AC power source with arbitrary waveform generator capable of being used in stand-alone mode in various applications for IEC 61000-4-X at pre or full-compliance. The measurement of flicker requires a fixed, stable source impedance the Profline system provides a precision power source to accurately simulate this impedance by careful control of the relationship between voltage and current. This IEC 61000-3-3 rental solution eliminates the need for a costly physical impedance.

The Profline 2105 is a reliable solution for testing to standards EN/IEC 61000-3-2, EN/IEC 61000-3-3, EN/IEC 61000-4-11, EN/IEC 61000-4-13, and EN/IEC 61000-4-14. Measurements are made using precision, no burden, active hall-effect current transformers connected via a dedicated cable to a multichannel fast Data Acquisition Card (DAQ) fitted inside a PC. One voltage and three current measuring channels are used to make simultaneous measurement of both current and voltage. 

ProfLine - Data Sheet Teseq - Harmonics & Flicker NSG1007 - Data Sheet

Specifications

Common Standards

EN/IEC 61000-3-2, EN/IEC 61000-3-3, EN/IEC 61000-4-11,

EN/IEC 61000-4-13, & EN/IEC 61000-4-14 

Power Source

5kVA – single phase 0-270V, 18.5A

Synthesized impedance

Per IEC 725

Data Acquisition

4 channels

Sampling Rate

>200kHz (4000 times fundamental) per channel


Harmonics Analysis

 

  Range

Fundamental to 40th harmonic

  Fundamental

±0.05% FS ±0.05% / kHz

  Harmonics

±0.1% ±0.1% / kHz

  Measurement Window

Real time FFT of 200msec.

  Smoothing

1.5 sec.

Flicker Analysis

 

  Range

0.4- 5 Pst

  Accuracy

3%

  Resolution

0.01

  Integration Time

10 mins

  Plt

0.4 - 5

  dmax

0.1 – 100%

  dc

0.1 – 100%

  dt

0.1 – 100%

  dt over 3.3%

10 – 5000 ms

Other Immunity Testing

 

  IEC 61000-4-11

AC voltage dips, interrupts and variations with optional EOS1

  IEC 61000-4-13

Immunity to harmonics and interharmonics

  IEC 61000-4-14

Immunity to voltage fluctuations

  IEC 61000-4-17

Ripple on DC input power ports

Weight

5 kg, 11 pounds

Dimensions

9x43x56 cm, 3.5x17x22 inches

Other Immunity Testing

 

  IEC 61000-4-11

AC voltage dips, interrupts and variations with optional EOS1

  IEC 61000-4-13

Immunity to harmonics and interharmonics

  IEC 61000-4-14

Immunity to voltage fluctuations

  IEC 61000-4-17

Ripple on DC input power ports

Weight

5 kg, 11 pounds

Dimensions

9x43x56 cm, 3.5x17x22 inches

NSG 1007-5 Power Supply

 

Supply Option

208 or 400

Operating Modes 

AC, DC, or AC + DC

Frequency Range

16Hz-1000Hz

Total Power

5kVA

Load Power Factor

0-1 at full rated power

Output noise

(20 kHz to 1 MHz) <250 mVrms typical, <500 mVrms maximum

Harmonic distortion

 <1% from 16-66 Hz, <2% at 400 Hz, <3% at 800 Hz

DC offset

<20 mV

External amplitude modulation

Depth 0-10%, Frequency DC-2 kHz

Isolation voltage

300 Vrms output to chassis

AC mode current

 

Low range Steady state

37.0

Low range Peak repetitive

110.0

High range steady state

18.5

High range peak repetive

96.0

DC mode 

 

Supply option

208

Maximum power

3,500 Watts

Output noise

(20 kHz to 1 MHz) <250 mVrms typical, <500 mVrms Max

Line regulation

<0.1% FS for 10% Line change

Packing List/Accessories

Included with Rental Of Teseq ProfLine 2105

Below you will find a list of common accessories that you can expect to be delivered with the equipment. This is a generic standard list and should you require an exact connector or accessory please contact us prior to order shipping. A detailed list of these can be found on the "All Accessories" tab. 

 

ProfLine 2105

    • NSG 1007
    • CCN 1000-1
    • Power Cable
    • 4 Prong Power Cable for NSG 1007
    • DB-37/68 PIN HD - PC to CCN Cable
    • DB-9 Series Cable
    • USB Cable
    • Metal Terminal block Covers
    • Cable Brackets
    • 36 Pin Connectors
    • Red & Blue Cables
    • Red & Blue Wires
    • 40VEU to US Plug (installed)
    • 240V EU Power Plug
    • Quick Instal
    • Cal Instruction Tutorial
    • Desktop Computer
    • Power Supply with Cable
    • Monitor
    • Stand 
    • Display Port Cable
    • USB Cable
    • Shipping Case

 

Standards 

Below is a list of common standards for Harmonics & Flicker Tester:

 

  • EMC Directives
  • IEC/EN 61000-3-2
  • IEC/EN 61000-3-3
  • IEC/EN 61000-4-8
  • IEC/EN 61000-4-11
  • IEC/EN 61000-4-13
  • IEC/EN 61000-4-14
  • IEC/EN 61000-4-17
  • IEC/EN 61000-4-28
  • IEC/EN 61000-4-29
  • MIL STD 461
  • RTCA/DO 160

ProfLine Series/Options

ProfLine Series Components

 

ProfLine 2105-208 

    • NSG 1007-5-208 Power source
    • CCN 1000-1 1-phase coupling unit
    • DAQ card
    • Interface cable
    • WIN 2100 H&F test software
    • WIN 2110 PQT test software
    • Pre-confi gured PC
    • USB cable

 

ProfLine 2105-400

    • NSG 1007-5-400 Power source
    • CCN 1000-1 1-phase coupling unit
    • DAQ card
    • Interface cable
    • WIN 2100 H&F test software
    • WIN 2110 PQT test software
    • Pre-confi gured PC
    • USB cable

 

ProfLine Series Options
INA 2151 1-phase IEC 61000-3-3 16 Amp reference impedance
CCN 1000-1L

1-phase coupling unit with integrated IEC 61000-3-3 16 Amp impedance

INA 2188

Rack mounting kit for CCN 1000-1

INA 2189 Rack mounting kit for NSG 1007-5
WIN 2106

Test software for IEC 61000-3-11 and IEC 61000-3-12

Option 8

1 m magnetic loop antenna 100 A/m continuous and 300 A/m for 3 s

Option 11-1

1-phase AC switch used to switch power between the source (set to the lower required voltage) and the mains supply in a time between 1-5 us. For details specification please see separate datasheet.

Avionics

Avionics immunity & emissions test capability for DO-160, Airbus and Boeing

 

  

You may also like