A NSG3060 CDN3063 - Teseq EFT, Surge, & Ringwave - 3 Phase

Immunity System 3-Phase CDN

A NSG3060 CDN3063 - Teseq EFT, Surge, & Ringwave - 3 Phase

Conducted Immunity System Features 

      • 6.6kV Surge, Ring Wave, EFT, & 1-Phase CDN
      • ISO 17025 Calibration All Components
      • CDNs - 270 Voltage/ 16Amps 1-Phase EFT & Surge
      • Free Technical Support & 2 Days Free Transit
      • Touch Panel Screen, Easy to RENTALuse Architecture 
      • Both IEC and ANSI coupling methods
      • Turnkey Solution - Arrives Ready for Testing!

Overview

This system by Teseq includes the NSG 3060 for EFT to 4.8kV, Surge to 6.6kV, 100 kHz Ringwave to 6.6kV with a  three phase EFT & Surge CDN (480v/32amps).  This is the combination of both the CDN 3063 and NSG 3060 which are priced and often rented desperately. This product is designed primarily for cable-borne transient interference tests. Both the pulse generator and the coupling/decoupling network come with an ISO 17025 accredited calibration.This is a combination of the NSG 3060 and CDN 3063, which can be rented as a complete system, or individually.

This Immunity Testing System was created for maximum reliability in a wide range of test setups. Over temperature protection, which allows short term operation at currents exceeding the nominal rating, prevents damage to internal components. The combination of both the NSG 3060 and CDN 3063 takes into account EUT power voltage levels allowing for testing to ANSI C62.41 and many others.

NSG 3060 & CDN Test Accessories

Conducted Immunity System Features 

      • 6.6kV Surge, Ring Wave, EFT, & 1-Phase CDN
      • ISO 17025 Calibration All Components
      • CDNs - 270 Voltage/ 16Amps 1-Phase EFT & Surge
      • Free Technical Support & 2 Days Free Transit
      • Touch Panel Screen, Easy to RENTALuse Architecture 
      • Both IEC and ANSI coupling methods
      • Turnkey Solution - Arrives Ready for Testing!

Overview

This system by Teseq includes the NSG 3060 for EFT to 4.8kV, Surge to 6.6kV, 100 kHz Ringwave to 6.6kV with a  three phase EFT & Surge CDN (480v/32amps).  This is the combination of both the CDN 3063 and NSG 3060 which are priced and often rented desperately. This product is designed primarily for cable-borne transient interference tests. Both the pulse generator and the coupling/decoupling network come with an ISO 17025 accredited calibration.This is a combination of the NSG 3060 and CDN 3063, which can be rented as a complete system, or individually.

This Immunity Testing System was created for maximum reliability in a wide range of test setups. Over temperature protection, which allows short term operation at currents exceeding the nominal rating, prevents damage to internal components. The combination of both the NSG 3060 and CDN 3063 takes into account EUT power voltage levels allowing for testing to ANSI C62.41 and many others.

Data Sheet - NSG 3060Data Sheet - CDN 3063 Application Guide - CDNs

Common Standards

EN/IEC 61000-4-4, EN/IEC 61000-4-5, EN/IEC 61000-4-12, 

ANSI C62.41, ANSI C62.45, & UL 1449

EFT Burst 5/50ns:

 

  Standards

IEC 61000-4-4, ed.3

  Voltage Waveform into 50Ω load

5ns Rise Time±30%, 50ns pulse width ±30%,

  Voltage Waveform into 1000Ω load

5ns Rise Time±30%, 50ns pulse width ±30%,

  Voltage Amplitude

±100V – 2.4kV into 50Ω, ± 200V – 4.8kV into 1000Ω


  Burst Duration

1µ to 1999 s

  Burst Period

1 ms to 4200 s

  Frequency

100Hz to 1000kHz

Combination Wave Surge:

 

  Standards

IEC 61000-4-5 ed. 3, EN 61000-4-5, ANSI C62.41.2 Cat A& B, UL 1449 ed. 3 sec. 37, ANSI C62.45

  Open Circuit Voltage Waveform

1.2µs Front Time ±30%, 50µs Duration ±20%

  Short Circuit Current Waveform

8µ Front Time ±20%, 20µs Duration ±20%

  Peak Open Circuit Voltage

200V–6.6kV

  Peak Short Circuit Current

100A–3.3kA @2 Ω, 16.6-550A@12Ω

100kHz Ringwave:

 

  Standards

IEC 61000-4-12, EN 61000-4-12, ANSI C62.41.2 Cat A& B,   ANSI C62.45

  Open Circuit Voltage Waveform

100kHz Damped Cosine, risetime=.5µs+/-30%,

Damping= 40%/peak

  Peak Open Circuit Voltage

200V–6.6kV @12 Ω or @ 30 Ω

  Peak Short Circuit Current

±6.6 to ±220 A ±10%@30 Ω

±16.6 to ±550 A ±10%@12 Ω

  Impulse Repetition Rate

10s from 200V to 4400V, 20s from 4401V to 6600V

Dips and Interrupts:

INA 6502 external variac is available as a separate option

 

Common Standards

EN IEC 61000-4-4, EN IEC 61000-4-5, EN 61000-4-12,

ANSI C62.41, C62.45, UL 1449

External Three Phase CDN 3063:

Other optional CDN’s (CDN 3063, 3083) are available also

  AC Voltage             

30-480 VAC, single or 3 phase

  AC Current

32 A  continuous, Max 50A for 10 min.

  DC Voltage

0-125 VDC, 225 VDC if current <7A

  DC Current

32 A  continuous, Max 50A for 10 min

  Control

Automatic through the NSG3060

  Connection to generator

Fischer S105 A 004/10.7

  Weight

42 kilograms, 100 pounds

  Dimensions

45x31x56 cm, 18x12x22 inches

Dips and Interrupts:

INA 6502 external variac is available as a separate option

 

Included with Rental Of Teseq NSG 3060

Below you will find a list of common accessories that you can expect to be delivered with the equipment. This is a generic standard list and should you require an exact connector or accessory please contact us prior to order shipping. We are also excited to offer many different testing accessories not standard with the immunity generator. A detailed list of these can be found on the "All Accessories" tab. 

 

NSG 3060

    • Conducted Immunity System
    • Control Software USB with License
    • Calibration Documentation
    • Power Cord
    • Laptop with Charger
    • Cross Over/ Ethernet Cable
    • Printed Manual 
    • Interlock/Keeper
    • Black Plastic Screw
    • WIN3000 Installation Guide
    • Shipping Case
      • Weight: 140 LBS
      • Dimensions: 28x26x18 

 

CDN 3063

    • CDN 3063 serial#
    • Power Cable3
    • Printed Manual CDN 3063
    • Calibration Documentation
    • (2) Surge Fischer/Fischer Cables
    • EFT  HV  SHV to SHV Cable
    • Allen Key
    • 25 Pin System Cable - CDN 3063 to Generator
    • Ground Strap
    • Red Shipping Case 

 

Rent coupler decoupler networks (CDN)s from a preferred rental partner of Ametek CTS. 

Take advantage of A2LA ISO 17025 calibrations and fast deliveries!

 

NSG 3060 Full Accessory List
Item Capabilities
CDN 3061 Single phase 270 V / 16 A automatic coupling decoupling network
CDN 3063

Three phase 480 V / 32 A automatic coupling decoupling networks

CDN 3083S-100

Manual 3-phase coupler for Surge (8 kV) only (combination and ring wave) with EUT current up to 100 A / 200 A

CDN 3083B-100 Manual 3-phase coupler for EFT / Burst (8 kV) only with EUT supply up to 690 VAC (1000 VDC) / 100 A

CDN HSS2

Coupling network for 2 kV surge pulse 1.2 / 50 μs IEC/EN 61000-4-5 on unshielded symmetrical high speed telecom lines (Ethernet)

CNV504N1.3

4kV coupler/decoupler for Surge & Ringwave on 4 data lines

CDN 3425 

Teseq Burst/EFT couple pulses to data lines.

CM.CCL

Capacitive coupling clamp by Thermo-Keytek is designed for EFT pulses on I/O lines or data lines 

CDN 3063-C32

Combined surge & burst coupling network for 480 VAC Ph-Ph, 32 A

CDN 3063-C63

Combined surge & burst coupling network for 480 VAC Ph-Ph, 63 A

CDN 8014/8015

Capacitive coupling clamp for burst

CDN 163

Burst coupling network 100 A per phase (coupling all to ref ground)

CDN 117/118

Coupling networks for signal-/data lines (surge)

CAS 3025

Burst/EFT verification set

MD 200A

Voltage differential probe 7 kV

MD 300

Current probe 5 kA

INA 6501

Manual step transformer, 16 AAC, 0/40/70/80%

INA 6502

Automatic step transformer, 16 AAC, 0/40/70/80%

VAR 3005-S16

Automatic variable transformer, 1 x 16 A

VAR 3005-D16

Automatic variable transformer, 2 x 16 A

MFO 6501

Manual magnetic field option -4-8

MFO 6502

Automatic magnetic field option -4-8

INA 701

Magnetic field coil 1 x 1 m; with MFO max. 3.6 A/m -4-8; Surge* max. 1200 A/m -4-9

INA 702

Magnetic field coil 1 x 1 m, with MFO max. 40 A/m -4-8; Surge* max. 1200 A/m -4-9 *) Pulse shape adapter INA 752 needed to surge generator

INA 752

Pulse shape adapter

  

I would recommend Transient Specialists. Transient Specialists always provides quality products within the established timeframes. The equipment always meets the specifications and properly shipped within the time frames within the time frames promised.

Scott D., TUV SUD Canada

 

Transient Specialists has been outstanding at working with us for our specialized EMC equipment rental needs. Fast shipments and excellent accommodation for some customized setups. I recommend them highly and they are a pleasure to partner with!

John H., Gates Air, Inc.

 

Laura, I want to thank you and Goran for your excellent customer service and turn around time on the rentals and the calibration documents.  

Adam P., Clark Testing

 

Working for a testing company I deal with renting equipment all the time.  Transient Specialist is the first company I call on my list of rental houses because of their great personnel, prompt delivery of the equipment, knowledgeable and accommodating to the customers needs.

Richard T., National Technical Systems