Keytek ECAT 3-Phase Surge/EFT Coupler (CDN) Module

ECAT 3-Phase Surge/EFT CDN

Keytek ECAT 3-Phase Surge/EFT Coupler (CDN) Module

Availability: In Stock - Order by 3PM Ships Today!

ECAT E4554 Features 

      • Coupler Decoupler Network (CDN) for ECAT
      • ISO 17025 Calibration Included
      • Compliant to the Latest Standards
      • Both 480 Volt & 600 Volt Available.  
      • Free Technical Support & 2 Days Free Transit
      • Must be Used with ECAT E103 Controller

Overview

Thermo Keytek module for ECATS.  The E 4554 A is three-phase ac line coupler/decoupler for surge and EFT modules requires the E103 controller, and a transient generator module, the E501b surge module, E411 EFT module or the E503 ringwave module can be rented / purchased at an additional cost.

ECAT E4554 Features 

      • Coupler Decoupler Network (CDN) for ECAT
      • ISO 17025 Calibration Included
      • Compliant to the Latest Standards
      • Both 480 Volt & 600 Volt Available.  
      • Free Technical Support & 2 Days Free Transit
      • Must be Used with ECAT E103 Controller

Overview

Thermo Keytek module for ECATS.  The E 4554 A is three-phase ac line coupler/decoupler for surge and EFT modules requires the E103 controller, and a transient generator module, the E501b surge module, E411 EFT module or the E503 ringwave module can be rented / purchased at an additional cost.

Data Sheet

E4554 Three Phase Coupler/Decoupler

 

Standards

IEC 61000-4-4, IEC 61000-4-5, EN 61000-4-4, EN 61000-4-5, ANSI/IEEE C62.41, C62.45, UL 1449

Voltage

480V rms AC, three phase to 6kV

Current

32A

Monitoring

Monitoring and peak detection of surge voltage across any two manually-selected lines.  Monitoring can be at the EUT or at the front panel of the coupler/decoupler.

Common Modules

 

ECAT Series Full Accessory
Item Capabilities
ECAT Model E411 EFT/Noise Burst simulator for testing in accordance with IEC 61000-4-4 Edition 2 to 4.4kV
ECAT Model E412 EFT/Noise Burst simulator with built-in, single phase AC mains coupler/decoupler for testing in accordance with IEC 61000-4-4 Edition 2 to 4.4kV. Model E412 features all specifications and options noted in Model E411 (above), as well as the following:
ECAT Model E421 FT/Noise™ Burst Simulator for IEC 61000-4-4 Edition 2 to 8 k
ECAT Model E501B Plug-in combination wave surge simulator to produce the combination waves required by IEC 6100-4-5, ANSI/IEEE C62.41 Cat. B and UL 1449 at 3kA
ECAT Model E502B Plug-in module to produce the telecommunications surge wave required by IEC 61000-4-5, FCC Part 68 and ITU Rec K.17, K.20, and K.21 (formerly CCITT
ECAT Model E503 Plug-in module to produce the ring waves specified by ANSI/IEEE C62.41 Cat. A and B, and various UL standards, including UL 864
ECAT Model E504A Plug-in module to produce the combination wave required by UL 1449 (some devices must also be tested using the E501A surge module)
ECAT Model E505A Plug-in module that produces the lightning surge waveforms required by FCC Part 68
ECAT Model E506-4W Plug-in module to produce the 2/10 µs surges required by Telcordia GR-1089 CORE for up to five-wire (four terminal) testing
ECAT Model E508 and E508-12P Plug-in modules to produce the 10/360 µs surges required by Telcordia GR-1089 CORE
ECAT Model E510A Plug-in module to produce combination wave specified by ANSI/IEEE C62.41 Cat. B and IEC 61000 4-5 to 10kV and 5kA
ECAT Model E511 Plug-in module to provide combination waves to 6 kV and 5 kA, as required by British Telecom standards
ECAT Model E513 Plug-in module to produce voltage ramps for testing surge protection components such as gas tube arrestors; meets surge simulator requirements of UL 864
ECAT Model E514 Surge simulator for 10/1000 µs current waves
ECAT Model E515 Module to produce the 10/250 µs surges required by Telcordia GR-1089-CORE
ECAT Model E518 Plug-in module to produce the 10/1000µs waveforms to 2kV as required by Telcordia GR-1089-CORE for both Lightning Surge and Protection Coordination. Includes HB-ECAT
ECAT Models E521 and E522 Surge systems that produce the high voltage, high current combination waves required by ANSI standards for service entrance and outside connected electronics; meets requirements of IEC 61000-4-5 for all exposure categories. ECAT Model E521 includes built-in AC coupler/decoupler for singlephase lines to 480V, 32A; ECAT Model E522 includes built-in AC coupler/decoupler for three-phase lines to 480V, 32A/phase (actual AC mains current per AC line connector limits).
ECAT Model E551 A single-phase AC line (power lines) coupler/decoupler for surge waves, as specified by IEC 61000-4-5
ECAT Models EP61 and EP62 Plug-in modules provide swells, dips and interrupts on AC power mains in compliance with, and exceeding the requirements of IEC 61000-4-11 Edition 2. Model EP61 for single-phase AC lines to 240 RMS, 16A; Model EP62 for single-phase AC lines to 240 RMS, 32A
ECAT Model E455x Single and three-phase AC line coupler/decouplers for EFT and Surge waves, as specified by IEC 61000-4-4 Edition 2 and IEC 61000-4-5