UCS 500N7 Rental - EM Test Conducted Immunity System

EM Test 7kV Transient Platform:

  • 7kV Surge, 5.5kV EFT, & 6kV 100kHz Ringwave 
  • Built-in CDN 300V/16Amps AC & 100V/10Amps DC
  • Includes Laptop with iec.control Software
  • Current ISO 17025 Cal & 2 Days Free Transit Time
  • Variety of Rental CDN, CCLs, & Data Line Couplers 

Options/Equipment


Included Items, View Packing List

Got Questions about the equipment? Get technical support

Two FREE days transit time with every rental

Request A Quote

EM Test UCS 500N Test Accessories

Description

Overview

The EM Test UCS500N7 is an EMC Immunity Test equipment is an all in one box for testing EFT to 5.5kV, Surge to 7kV and 100kHz Ringwave to 6 kV, with built-in single phase coupler and software. This test equipment provides optional Dips and Interrupts testing with the V4780 S2 external variac. The UCS500N7 includes a built-in CDN for single phase it can be extended for testing three-phse DUT's by means of automatically controlled external coupling network up to 100A. 

This Immunity Test Generator can be operated via the front panel or by remote via the built-in USB or GPIB interface. Fail inputs allow control an ongoing test sequences based on the status of the DUT. Monitoring outputs (BNC) are offered for easy signal measurement and verification. This EMI test equipment provides a fully compliant that goes to levels beyond common testing requirements.

The UCS500n7 includes many reprogrammed test routines ideal for testing to EN/IEC 61000-4-4, EN/IEC 61000-4-5, EN/IEC 61000-4-11, EN/IEC 61000-4-12, CEMark, ANSI/IEEE C62.41 cat. B, EN IEC 61000-6-1, and EN IEC 61000-6-2. This product also includes both pre-programmed standard tests and a quick start menu allowing for parameters to be changed on-line during the test to evaluate the susceptibility level of an individual DUT. 

Data SheetUser Manual

Specifications

Common Standards

EN/IEC 61000-4-4EN/IEC 61000-4-5EN/IEC 61000-4-11EN/IEC 61000-4-12,

CE MarkANSI/IEEE C62.41 cat. B, EN 61000-6-1, -6-2

Integrated CDN:

 

  AC Voltage and Current              

300V/16A; 50/60Hz

  DC Voltage and Current

300V/10A

EFT Burst 5/50ns:

 


  Standards

IEC 61000-4-5, ed.3, CEMark

  Voltage Waveform into 50Ω load

5ns Rise Time ±1.5ns,  50µs pulse width ±15ns

  Voltage Waveform into 1000Ω load

5ns Rise Time ±1.5ns,  50µs pulse width -15/+100ns

  Voltage Amplitude

200V-5500 V ±10%, 100V-2,750V ±10% into 50Ω

  Burst Duration  

td = 0.10ms - 999ms

  Burst Period

tr = 10ms - 9,999ms

  Frequency

f = 0.1kHz - 1,000kHz

Combination Wave Surge:

 

  Standards

IEC 61000-4-5 ed. 3, EN 61000-4-5, ANSI C62.41.2 Cat A& B, UL 1449 ed. 3 sec. 37, ANSI C62.45, EN 61000-6-1, -6-2

  Open Circuit Voltage Waveform

1.2µs Front Time ±30%,  50µs Duration ± 20%

  Short Circuit Current Waveform

8µ Front Time ±20%, 20µs Duration ± 20%

  Peak Open Circuit Voltage

250V–7kV ±10% @2 Ω

  Peak Short Circuit Current

125A–3.5kA  ±10%@2 Ω

  Pulse Repetition Rate

2s – 999s

100 kHz Ringwave:

 

  Standards

IEC 61000-4-12, EN 61000-4-12, ANSI C62.41.2 Cat A& B,   ANSI C62.45

  Open Circuit Voltage Waveform

100kHz Damped Cosine, Rise Time=.5µs±-30%,

Damping= 40%/peak

  Peak Open Circuit Voltage

250V–6kV ± 10% @12 Ω or @ 30 Ω

  Peak Short Circuit Current

200A±10%@30 Ωohms, 500A ±10%@12 Ω

  Pulse Repetition Rate

1s – 999s

Dips and Interrupts:

Optional External V4780 S2

  Standards  

EN/IEC 61000-4-11 and EN 61000-6-1, -6-2

  Voltage Dips:

40%, 70%, 80% , 100%residual voltage ±5%

  Short Interrupts

0% residual voltage ±5%

  Transition Time

Rise Time, Fall Time ≥1µs & ≤5µs

  Input Voltage/Current

50-250VAC, 50/60Hz, 16A Max.

Weight

29kg, 64 pounds

Dimensions

43x43x48cm, 17x17x19 inches

All Accessories

Rent coupler decoupler networks (CDN)s & accessories from a preferred rental partner of Ametek CTS. 

Take advantage of A2LA ISO 17025 calibrations and fast deliveries!

 

UCS 500N7 Full Accessory List
Item Capabilities
V4780 S2
EMTest automated external transformer for the UCS 500n7 and UCS 500n5 generators to perform the dips and interrupts test for EN IEC 61000-4-11.
CNI 503

3PHASE COUPLING/DECOUPLING NETWORKS FOR BURST AND SURGE

MV 2616

MOTORISED VARIAC FOR VOLTAGE VARIATION

V 4780 TAPPED VOLTAGE TRANSFORMER FOR VOLTAGE DIPS AND INTERRUPTIONS

V 4780S2

 TAPPED VOLTAGE TRANSFORMER FOR VOLTAGE DIPS AND INTERRUPTIONS

CNV 504/508

SURGE COUPLING/DECOUPLING NETWORKS FOR SIGNAL/DATA LINES

MS 100N

MAGNETIC FIELD COIL FOR POWER-FREQUENCY AND PULSED MAGNETIC FIELDS

HFK

CAPACITIVE COUPLING CLAMP

CA EFT KIT

VERIFICATION KIT FOR EFT/BURST PULSES

KW50

100:1 divider, 50 ohm

KW1000

500:1 divider, 1,000 ohm

CNV 504Nx

Coupling network for 4 signal/data lines as per IEC 61000-4-5 Ed 3.0

CNV 508Nx

Coupling network for 8 signal/data lines as per IEC 61000-4-5 Ed 3.0

CNI 508N2 Assembly

Set of coupling/decoupling and protection networks for testing unshielded and shielded high-speed communication lines (Ethernet lines

V 4780

Tapped autotransformer as per IEC 61000-4-11 Ed.2

V 4780 S2

Tapped autotransformer as per IEC 61000-4-11 Ed.2 with automatic change of tap

  

Standards

Widely Used Standards

Below is a list of common standards for this conducted immunity generator. This is by no means the only standards that it can cover. Please confirm prior to renting as capabilities are often based upon accessories.

  • ANSI/IEEE C62.41
  • ECE-R10
  • EN 61000-4-11
  • EN 61000-4-12
  • EN 61000-4-29
  • EN 61000-4-4
  • EN 61000-4-5
  • EN 61000-4-8
  • EN 61000-4-9
  • EN 61000-6-1
  • EN 61000-6-2
  • EN 61543
  • IEC 60255-22-5
  • IEC 61000-4-11
  • IEC 61000-4-12
  • IEC 61000-4-29
  • IEC 61000-4-4
  • IEC 61000-4-5
  • IEC 61000-4-8
  • IEC 61000-4-9
  • IEC 61008-1
  • IEC 61009-1
  • IEC 61326
  • IEC 61850-3
  • IEEE 1547
  • ITU-T K.20
  • ITU-T K.21
  • ITU-T K.45
  • UL 1741
  • UL 244
  • UL 943