Description
Overview
This variation (with modules) of the EMC Partner TRA3000 platform has the capabilities for combination wave surge and electrical fast transients to 4kV and includes a single phase built in coupler 300v/15a AC and 300v/10a DC. We also offer another platform with respective modules for Common Mode or Dips/Interrupts providing a solution for IEC 61000-4-16. All of our variations of these test generators come with ISO 17025 accredited calibration and technical support.
This Immunity Test Generator has been created for CE transient testing as well as fulfilling IEC basic standard requirements. This EMC Patner pulse generator includes both an Ethernet Port for control communication and test reporting that includes laboratory environmental conditions.This products "Plug and Play" architecture allows for system to automatically identify hardware then re-configure testing menu to reflect the change.
The TRA3000 is a single unit testing system for EN/IEC 61000-4-4, EN/IEC 61000-4-5, and CE Marking. With the common mode or dips/interrupts available for testing to EN/IEC 61000-4-11 and EN/IEC 61000-4-16, this design offers flexibility depending on testing needs. As an added bonus EMC Partner does not require proprietary software all reports are HTML based and can be viewed with web browsers.Data Sheet User Manual
Specifications
Power frequency synchronisation |
16Hz up to 400Hz |
Coupling path selection EFT |
L, N, PE, L+N, L+PE, N+PE, L+N+ PE |
Communication Interfaces |
Ethernet, USB & RS232 |
DC Voltage and Current |
110VDC/16A |
Atmospheric measurement |
Temperature & Humidity |
Test report format |
HTML |
PS3 control |
DC, 16.7Hz, 50Hz, 60Hz, 400Hz |
EUT Power monitor |
10V = 400Vac |
Surge voltage monitor |
10V = 4kV |
Surge current monitor |
10V = 2kA |
Trigger |
BNC maximum 12V |
Trigger mode |
Auto, manual |
EFT/Burst 5/50ns: |
|
Standards |
EN/IEC 61000-4-4, CEMark |
Voltage Waveform into 50Ω load |
5ns Rise Time ±30%, 50ns pulse width ±30% |
Voltage Waveform into 1000Ω load |
5ns Rise Time ±30%, 50ns pulse width ±30% |
Voltage Amplitude |
250 up to 4,4 kV ±10%, 125V up to 2,2kV ±10% into 50Ω |
Burst Duration |
td = 0.01ms – 30ms |
Burst Period |
tr = 1ms – 1,000ms |
Voltage range |
0.25 up to 4.4kV |
Source impedance |
50ohm |
Pulse front time at 50ohm |
5ns |
Pulse duration at 50ohm |
50ns |
Spike repetition frequency |
up to 1MHz |
Spike distribution |
IEC burst pattern and random |
Burst repetition |
1 up to 1000ms |
Surge Combination Wave: |
|
Standards |
EN/IEC 61000-4-5 , CEMark |
Open Circuit Voltage Waveform |
250V – 4,100V, Front Time1.2us ±30%, 50µs Duration ± 20% |
Short Circuit Current Waveform |
125A- 2050A, 8µ Front Time ±20%, 20µs Duration ±20% |
Peak Open Circuit Voltage |
250V–4100V ±10% |
Peak Short Circuit Current |
125A–2050A ±10%@2 Ω, 20.8-500A ±10%@12Ω |
Pulse Repetition Rate |
MAX. 1Hz (1s – 999s) |
Pulse front time at open circuit |
1.2µs |
Pulse duration at open circuit |
50µs |
Source Impedance |
2ohm |
Current range |
0.125 up to 2.05kA |
Pulse front time at short circuit |
8µs |
Pulse duration at short circuit |
20µs |
Weight |
25kg, 55 pounds |
Packing List/Accessories
Included with Rental of EMC Partner TRA3000
Below you will find a list of common accessories that you can expect to be delivered with the equipment. This is a generic standard list and should you require an exact connector or accessory please contact us prior to order shipping. We are also excited to offer many different testing accessories not standard with the immunity generator. A detailed list of these can be found on the "All Accessories" tab.
TRA 3000
- TRA 3000 Serial #
- Power Cord
- EUT Power Cable with MC Connector
- Ethernet Cable
- (2) U Shaped Jumpers (attached to the generator)
- EU to USA Adapter Plug
- USB Stick with Software
- Printed Manual
- Calibration Documentation
- Pelican Shipping Case
All Accessories
Item | Capabilities |
CDN2000-06-32 for Three Phase Coupling | Add three phase capability with automatic or manual three phase coupling networks. The CDN2000A-06-32 and CDN2000-06-32, can be used for EFT, CWG surge and ring wave. Coupling path selection is either automatic under software control, or manual on the CDN front panel. All coupling networks fulfill the requirements laid down in the IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-12 (ring wave) and ANSI C62.41 standards. |
CDN2000A-06-63 for Three Phase Coupling |
Add higher current three phase capability with automatic coupling network CDN2000A06-63. This can be used for EFT, CWG surge and ring wave. Coupling path selection is automatic under software control. This coupling network fulfills the requirements laid down in the IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-12 (ring wave) and ANSI C62.41 standards. |
CDN-A-3P100-480 F / F-S for 100A three Phase Coupling |
Three phase CDN with line voltages L to N/PE=280V and L to L=480V, line current 100A per phase. Automatic coupling path selection for EFT or EFT and SURGE controlled by TRA2000, TRA2004, TRA2006, TRA3000. |
CDN-A-3P100-690 F / F-S for 100A three Phase Coupling | Three phase CDN with line voltages L to N/PE=398V and L to L=690V, line current 100A per phase. Automatic coupling path selection for EFT or EFT and SURGE controlled by TRA2000, TRA2004, TRA2006, TRA3000 and MIG0603INx. |
CDN2000-06-25 Three Phase Coupling |
CDN2000-06-25 can be used for Combination wave, Ring wave and EFT testing. With an EMC PARTNER oscillatory wave tester, power and up to four data lines using the 100kHz and 1MHz oscillatory waves can be tested according to IEC61000-4-18. |
CN16-450C |
Single phase CDN for superimposing surge and EFT into power lines. EUT power supply up to 16A at 115V 400Hz. For use ONLY with TRA2004 or TRA2006 |
CN2000TT MC |
Test pistol for direct current injection of surge and 10/700µs according to IEC 61000-4-5. Cable length 1.5m with MC plugs. The test pistols can be used together with MIG system equipped with MC plug outputs on front panel or networks (NW). |
TEST SETUP |
Test package for EFT testing. This includes 1m cable with 2 x 470kOhm resistors and mechanical connections to the EFT reference plane. |
VERI50EFT |
50ohm termination with high voltage BNC connector and integrated divider for EFT calibration / verification in accordance with IEC 61000-4-4 Ed2 |
VERI1KEFT |
1kOhm termination with high voltage BNC connector and integrated divider for EFT calibration / verification in accordance with IEC 61000-4-4 Ed2. |
CN-EFT1000 |
Capacitive coupling clamp 100ohm according to IEC 61000-4-4 including 1m coax cable with BNC connectors. |
CN-BALUN |
Balanced/unbalanced transmission line transformer for EFT and 1MHz damped sine according to ANSI/IEEE C.37.90. Including coaxial cable with HV-BNC plugs (3x 0.5m), test tip + HV-BNC adapter (1 red, 1 black) and HV-BNC connector (2x). |
ESD2000 |
Coupling network for 8 signal/data lines as per IEC 61000-4-5 Ed 3.0 |
EXT-TRA3000E |
ESD discharge module to fulfill IEC 61000-4-2 requirements. Self contained unit with high voltage generation. For full details, please refer to brochure “ESD Testers”. For use ONLY with TRA3000. |
ADAPTER EFT-CDN |
Adapter cable which enables EFT impulses to be measured at the output of either a single or three phase CDN as required by IEC 61000-4-4 Ed.2. |
CDN-UTP |
The CDN-UTP is a sophisticated coupling and de-coupling network for superimposing surge impulses on balanced communication lines in accordance with IEC 61000-4-5 (Figure 12: unshielded symmetrical interconnection lines), ITU-K20, K21 and FCC part 68. It is designed for 1.2/50µs and 10/700µs pulses up to 6.6kV. CDN-UTP is also available with 4 pairs (8 lines) as the CDN-UTP8 version. |
Standards
Common Standards for TRA Platform
- IEC 61000-4-2 : Testing and measurement techniques - Electrostatic discharge immunity test.
- IEC 61000-4-4 : Testing and measurement techniques - Electrical fast transient / burst immunity test.
- IEC 61000-4-5: Testing and measurement techniques - Surge immunity test.
- IEC 61000-4-8: Testing and measurement techniques - Power frequency magnetic field immunity test.
- IEC 61000-4-9: Testing and measurement techniques - Pulse magnetic field immunity test.
- IEC 61000-4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests.
- IEC 61000-4-16 : Testing and measurement techniques - Test for immunity to conducted, common mode disturbances in the frequency range 0Hz to 150kHz.
- IEC 61000-4-29: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations on d.c. input power port immunity tests.
- IEC 61000-4-34: Testing and measurement techniques - Voltage, dips, short interruptions and voltage variations immunity tests for equipment with mains current more than 16A per phase
Video
TRA3000 - Overview & Setup EMC Parnter
Description: This video provides an overview of the TRA3000 platform and software which includes a variety of immunity testing capabilities.