Solar 7054 - EMI Spike Tester to MIL-STD-461 CS06, DO-160 sec 17

Availability:
In Stock - Order By 3PM Ships Today!

600 Volt Spike Generator:

  • Provides 300kW Into Low Resistance Load
  • Compliant MIL-STD-461 CS06, DO-160 sec 17
  • Output 10 Volts to 600 Volts into 5 Ω or less.
  • Current ISO 17025 Cal & 2 Days Free Transit Time

Get weekly, two week, and monthly rentals on all products

Got Questions about the equipment? Get technical support

Two FREE days transit time with every rental

Request A Quote

Description

Conducted Immunity Generator Features 

      • Output 10 Volts to 600 Volts into 5 Ω or less.
      • Single pulse feature for controlled isolation of transient effects
      • Delivers more than 300 kW peak into 0.5 Ω load
      • Solar 2201 often rented with this system
      • Turnkey Solution - Arrives Ready for Testing!

Overview

The Solar 7054 is 600V spike generator delivering over 300 kW into low resistance loads with adjustable amplitude and the repetition rate. Our EMI test equipment rentals come with A2LA calibration & technical support. The transient shape approximates the curve given in Figure 19 of MIL-STD-462 with less than or equal to 2.0 µS rise time and approximately 10 µS fall time.

 

This Military EMC Immunity Test Generator has a source impedance less than 0.5 Ω. Two sets of output terminals allow either parallel or series injection into the power line. The output winding used for series injection can carry 25 A of power current. The output terminals are isolated from the chassis and the power cord.

The 7054 allows testing for method MIL-STD-461 CS06 and RTCA DO-160 Section 17 as well various missile specifications and other requirements. On 50, 60 or 400 Hz power lines the transient can be applied in a periodic manner to the negative or the positive half-cycle of the power frequency. This military rental includes output terminals for series or parallel injection.

Data SheetUser Manual

Specifications

Common Standards

MIL-STD-461 CS06, RTCA DO-160 Section 17, & Method 5006.1 of MIL-STD-826A 

Spike Amplitude

Continuously adjustable from 10 volts to over 600 volts peak

Repetition Time

Continuously adjustable from 0.8 to 10  p.p.s.

Wave Shape

Similar to Section 19 of MIL-STD-462

Rise time

2.0 µS rise time

Duration

10 µS fall time

Phase Adjustment

Pulse position adjustable from 0° to 360° periodically on 50,60 or 400 Hz sine wave

Internal Impedance

Less the 0.5 ohms

Weight

15kg, 35 pounds

Dimensions

48.26cm x17.78cm x 32.38cm (19” x 7” x 12.75”)

You may also like