Description
Overview
This test solution for MIL-STD-461 CS116 includes the Solar 9354-2 and the required commonly used accessory package. The test generator provides six damped six damped sinusoidal pulses (10 kHz, 100 kHz, 1 MHz, 10 MHz, 30 MHz, and 100 MHz), three double exponential pulses (6.4 µS, 70 µS, 500 µS). It also comes with an ISO 17025 accredited calibration. Please confirm prior to renting exact test equipment requirements.
9354-2 Data Sheet9354-2 User ManualSpecifications
Common Standards |
MIL-STD-461 CS116, RTCA DO-160 sec 22 |
Waveforms |
Nine selectable waveforms including: |
10 kHz damped oscillatory |
Open Circuit Voltage 30V Calculated Short Circuit Current 120A Source Impedance <.25 Ω |
100 kHz damped oscillatory
|
Open Circuit Voltage 300V Calculated Short Circuit Current 120A Source Impedance <2.5 Ω |
1 MHz damped oscillatory |
Open Circuit Voltage 3200V Calculated Short Circuit Current 128A Source Impedance <25 Ω |
10 MHz damped oscillatory |
Open Circuit Voltage 3200V Calculated Short Circuit Current 128A Source Impedance <25 Ω |
30 MHz damped oscillatory |
Open Circuit Voltage 1000V Calculated Short Circuit Current 20A Source Impedance <50 Ω |
100 MHz damped oscillatory |
Open Circuit Voltage 300V Calculated Short Circuit Current 6A Source Impedance <50 Ω |
30 MHz damped oscillatory |
Open Circuit Voltage 1000V Calculated Short Circuit Current 20A Source Impedance <50 Ω |
6.4µs double exponential |
Open Circuit Voltage 1600V Calculated Short Circuit Current 800A Source Impedance <2Ω Rise Time 100ns |
70µs double exponential |
Open Circuit Voltage 1600V Calculated Short Circuit Current 800A Source Impedance <2Ω Rise Time 6.4 µs |
120µs double exponential |
Open Circuit Voltage 750V Calculated Short Circuit Current 400A Source Impedance <4Ω Rise Time 40 µs |
Repetition |
.5 to 1 pulse per second, or manual trigger |
Weight |
25kg, 55 pounds |
Dimensions |
43.5cm X 33.0cm X 22.2cm (17.25” X 13” X8.75”) |
Common Standards |
MIL-STD-461 CS116, MIL-STD-461 CS115 |
Solar 9335-2 |
Coupling Clamp |
Voltage or Current transfer |
1:1 |
Voltage step-up (current step-down) |
1:1.5,3:1 |
Voltage step-down(current step-up) |
2:1 |
Source Impedance |
>.25Ω to 50Ω |
Weight |
8.36 lbs. |
Solar 9123 |
Clamp on Current Probe |
Dimensions |
13.97cm X20.32cm X 16.86cm (5.5” X 8” X 6.64”) |
Maximum Input Current |
60 Amps |
Weight |
1.9kg (4.2 lbs.) |
Solar 9125 |
Calibration fixture for the Solar 9233 |
Frequency Range |
20Hz to 500MHz |
Weight |
4.08 kg (9 lbs.) |
Dimensions |
32-44mm, 1.5” diameter window |
Solar 9142N |
Bulk Current Injection Probe |
Frequency Range |
2MHz to 500 MHz |
Window Diameter |
38mm(1.50”) |
Maximum Input Power |
200 Watts |
Maximum Input Current |
50 Amps |
Weight |
1.9kg (4.2 lbs.) |
Also includes: |