Description
Overview
The Solar CS116 accessory package is a complete accessory package for CS115 and CS116 testing with the Solar Electronics 9354-2 including calibration fixtures and attenuators. High power transient generators with source impedances from 0.25 Ω to 50 Ω can use this probe to deliver high peak voltage or high current pulses into the wires or cables passing through the window of the device.
The unique winding arrangement of this impedance matching probe provides step-up or step-down ratios with respect to either: 1) the source impedance of the connected generator, when used for injection, or 2) the load impedance of the connected receiver, when used for reception. This results in maximum power transfer into or out of the transformer winding formed by the cable bundle passing through the window.
9142-1N Data SheetSpecifications
Common Standards |
MIL-STD-461 CS116, MIL-STD-461 CS115 |
Solar 9335-2 |
Coupling Clamp |
Voltage or Current transfer |
1:1 |
Voltage step-up (current step-down) |
1:1.5,3:1 |
Voltage step-down(current step-up) |
2:1 |
Source Impedance |
>.25Ω to 50Ω |
Weight |
8.36 lbs. |
Solar 9123 |
Clamp on Current Probe |
Dimensions |
13.97cm X20.32cm X 16.86cm (5.5” X 8” X 6.64”) |
Maximum Input Current |
60 Amps |
Weight |
1.9kg (4.2 lbs.) |
Solar 9125 |
Calibration fixture for the Solar 9233 |
Frequency Range |
20Hz to 500MHz |
Weight |
4.08 kg (9 lbs.) |
Dimensions |
32-44mm, 1.5” diameter window |
Solar 9142N |
Bulk Current Injection Probe |
Frequency Range |
2MHz to 500 MHz |
Window Diameter |
38mm(1.50”) |
Maximum Input Power |
200 Watts |
Maximum Input Current |
50 Amps |
Weight |
1.9kg (4.2 lbs.) |
Also includes: |
9841-1 50 ohm load, 9410-1, 9454-1 attenuators, 9357-1 calibration fixture. |