CDN 3425 Rental - Teseq Burst/EFT Coupling Clamp

Teseq EFT CCL

CDN 3425 Rental - Teseq Burst/EFT Coupling Clamp

Coupling Clamp (CCL) Features 

      • New design, Includes Safety Cover & Interlock
      • ISO 17025 Calibration & 2 Days Free Transit
      • Compliant IEC 61000-4-4 Ed.2 & Ed.3
      • Can Work With Many Immunity Generators!
      • Replaces CDN 8014 and CDN 8015
      • Turnkey Solution - Arrives Ready for Testing!

Overview

The Teseq CDN3425 (Teseq CCL) main purpose is to couple Burst/EFT pulses to data lines. It can also be used to couple to mains lines where no CDN is available; for example, high current lines >200 A. This coupling decoupling network (CDN) capacitive coupling clamp (CCL) comes with an ISO 17025 accredited calibration and works with a many conducted immunity generators

The new design is fully compliant with the specifications of IEC 61000-4-4 Ed 2.0 2004, as well as with the draft of EN/IEC 61000-4-4 Ed 3.0 to be published in 2012. This model also replaces earlier models CDN 8014 and CDN 8015.The coupling capacitance between the coupling clamp and the cable laid in it depends on the cable characteristics. 

Coupling Clamp (CCL) Features 

      • New design, Includes Safety Cover & Interlock
      • ISO 17025 Calibration & 2 Days Free Transit
      • Compliant IEC 61000-4-4 Ed.2 & Ed.3
      • Can Work With Many Immunity Generators!
      • Replaces CDN 8014 and CDN 8015
      • Turnkey Solution - Arrives Ready for Testing!

Overview

The Teseq CDN3425 (Teseq CCL) main purpose is to couple Burst/EFT pulses to data lines. It can also be used to couple to mains lines where no CDN is available; for example, high current lines >200 A. This coupling decoupling network (CDN) capacitive coupling clamp (CCL) comes with an ISO 17025 accredited calibration and works with a many conducted immunity generators

The new design is fully compliant with the specifications of IEC 61000-4-4 Ed 2.0 2004, as well as with the draft of EN/IEC 61000-4-4 Ed 3.0 to be published in 2012. This model also replaces earlier models CDN 8014 and CDN 8015.The coupling capacitance between the coupling clamp and the cable laid in it depends on the cable characteristics. 

Data SheetUser ManualApplication Guide - CDNs

Common Standards

EN/IEC 61000-4-4

Max. permissible burst voltage

8 kV

Usable length of the clamp

1000mm

Diameter of the test cable:

4 to 40 mm

Connectors

SHV-NIM female, 50 Ω (on both ends)

Distance to the earth reference plane

100 mm

Dimensions

1100 x 200 x 110mm, 43.31 x 7.78 x 4.33in

Weight

7.5kg, 16.53lbs

I would recommend Transient Specialists. Transient Specialists always provides quality products within the established timeframes. The equipment always meets the specifications and properly shipped within the time frames within the time frames promised.

Scott D., TUV SUD Canada

 

Transient Specialists has been outstanding at working with us for our specialized EMC equipment rental needs. Fast shipments and excellent accommodation for some customized setups. I recommend them highly and they are a pleasure to partner with!

John H., Gates Air, Inc.

 

Laura, I want to thank you and Goran for your excellent customer service and turn around time on the rentals and the calibration documents.  

Adam P., Clark Testing

 

Working for a testing company I deal with renting equipment all the time.  Transient Specialist is the first company I call on my list of rental houses because of their great personnel, prompt delivery of the equipment, knowledgeable and accommodating to the customers needs.

Richard T., National Technical Systems