CDN HSS-2 - Teseq Ethernet Surge CDN for Communication Lines

Dateline CDN 8 Lines

CDN HSS-2 - Teseq Ethernet Surge CDN for Communication Lines

Ethernet CDN Features 

      • Max Current/Voltage 2kV/50Amps
      • ISO 17025 Accredited Calibration included
      • Coupling Mode: Common Mode 1,2, or 4 pairs
      • Designed for Fig. 11 of IEC 61000-4-5/ Ed.3/77B/674A/CD:2012-05
      • Turnkey Solution - Arrives Ready for Testing!

Overview

The Teseq CDN HSS-2 Coupling Decoupling Network is designed for convenient surge testing with 1.2/50 μs pulses, as defined in EN/IEC 61000-4-5, on unshielded symmetrical high speed telecommunication lines e.g. Ethernet. A2LA accredited calibration is included in the EMC rental equipment price. This product allows testing on ISDN and Ethernet with 10/100BaseT and 1000BaseT. With a surge test voltage of 2 kV is the maximal residual voltage at the AE port only 65 V due to the excellent decoupling network. Additional decoupling elements are not required to protect the auxiliary equipment (AE). 

Ethernet CDN Features 

      • Max Current/Voltage 2kV/50Amps
      • ISO 17025 Accredited Calibration included
      • Coupling Mode: Common Mode 1,2, or 4 pairs
      • Designed for Fig. 11 of IEC 61000-4-5/ Ed.3/77B/674A/CD:2012-05
      • Turnkey Solution - Arrives Ready for Testing!

Overview

The Teseq CDN HSS-2 Coupling Decoupling Network is designed for convenient surge testing with 1.2/50 μs pulses, as defined in EN/IEC 61000-4-5, on unshielded symmetrical high speed telecommunication lines e.g. Ethernet. A2LA accredited calibration is included in the EMC rental equipment price. This product allows testing on ISDN and Ethernet with 10/100BaseT and 1000BaseT. With a surge test voltage of 2 kV is the maximal residual voltage at the AE port only 65 V due to the excellent decoupling network. Additional decoupling elements are not required to protect the auxiliary equipment (AE). 

Data Sheet

Common Standards

EN/IEC 61000-4-5

Max. surge test voltage

2 kV  (1.2/50 µs pulse per EN IEC 61000-4-5)

Max. surge test current

50 A (8/20 µs pulse per EN IEC 61000-4-5)

Cable type

8 wire unshielded twisted pair high speed telecom lines (UTP)

Application

ISDN, 10/100 Base T, 1000 Base T

Insertion Loss

9dB at 100MHz

Max. Operating Speed

1000 Base T

Max. Operating Voltage

100 VDC between pairs

Max. Operating Current

1 A

Connection to generator

Fischer D103 A 023

Connection to EUT or AE

RJ45 female

Weight

15 kilograms, 33 pounds

Dimensions

20x20x47 cm, 8x8x18 inches

I would recommend Transient Specialists. Transient Specialists always provides quality products within the established timeframes. The equipment always meets the specifications and properly shipped within the time frames within the time frames promised.

Scott D., TUV SUD Canada

 

Transient Specialists has been outstanding at working with us for our specialized EMC equipment rental needs. Fast shipments and excellent accommodation for some customized setups. I recommend them highly and they are a pleasure to partner with!

John H., Gates Air, Inc.

 

Laura, I want to thank you and Goran for your excellent customer service and turn around time on the rentals and the calibration documents.  

Adam P., Clark Testing

 

Working for a testing company I deal with renting equipment all the time.  Transient Specialist is the first company I call on my list of rental houses because of their great personnel, prompt delivery of the equipment, knowledgeable and accommodating to the customers needs.

Richard T., National Technical Systems