Video Guides
BCI/Current Injection Clamp Method
The Teseq NSG 4070 is an ideal conducted RF Test system for bulk current injection or current clamp method according to a variety of commercial, military, and automotive requirements. The test setup includes a variety of components including bulk current injection probe, monitoring probe(s), attenuators, cabling, and external amplifiers if necessary.
Teseq System Overview
This video made by Teseq, provides an overview of this conducted RF immunity test system. It provides an overview of the system itself, accessories, including coupling clamps, controls, interface, and manipulating testing parameters. It also mentions briefly about compliance to IEC 61000-4-6 and other testing standards.
Data SheetTeseq - Software Download
Overview
The NSG4070 by Teseq is a multifunctional device for carrying out EMC testing for conducted and radiated immunity testing to a variety of standards. Take advantage of ISO 17025 calibrations, a variety of accessories, a quick delivery on this compact equipment.This Conducted RF Immunity Test Generator modular set-up using internal (80 Watts) or external amplifiers enables a large variety of applications.
Specifications
Common Standards |
EN/IEC 61000-4-6, EN/IEC 60601-1-2, ISO 11452-4, EN/IEC 62132 |
Generator |
|
Frequency Range |
9 kHz to 1 GHz |
Resolution |
1 Hz |
RF Level Range |
-60 dBm to +10 dBm |
1 Hz to 50 kHz |
|
Amplitude Modulation Resolution |
1 Hz |
Pulse Modulation Rise/Fall Time |
<1µs (10% to 90%) |
Pulse Modulation Frequency Range |
1 Hz to 50 kHz |
Pulse Modulation Freq. Resolution |
1 Hz |
Pulse Modulation Duty Cycle |
10% to 90% |
Power Meter |
|
Frequency Range |
9 kHz to 1 GHz |
Line Measurement Range |
Channel 1 -35 dBm to +27 dBm, Ch 2&3 -45 dBm to 20dBm |
Maximum Input |
+28 dBm |
Noise Level |
>5 dB below the measurement range |
Input Return Loss |
>20 dB (below 500MHz), >17 dB (500MHz to 1 Ghz) |
Connector |
BNC socket, 50Ω |
Power Amplifier |
|
Output Power |
Max 80W |
Frequency Range |
150 kHz to 230 MHz |
Input Impedance |
50 ohm |
Output Impedance |
50 ohm |
Direct RF Output |
To control an external amplifier |
Input Return Loss |
Min. 10 dB |
Output Return Loss |
Nominal Min. 9.5 dB, 0 dB without damage |
Gain |
Min 50 dBm |
Linear Output Power |
Min 48 dBm |
Max. Input Power without Damage |
Max. +10 dBm |
Harmonic Distortion |
Typ. <-20 dBc |
Weight |
15 kg, 33 pounds |
Dimensions |
45x43x15 cm, 17x16x6 inches |
Standards
Widely Used Standards
This list is a more comprehensive list of all the standards covered with this conducted RF Generator. For assured compliance to a particular standard, confirm prior to rental. This conducted immunity generator has the ability to either cover all, or part of the standards below.
- IEC/EN 61000-4-3
- IEC/EN 61000-4-6
- IEC/EN 61000-4-20
- IEC/EN 61000-4-21
- CISPR 24
- EN 61000-6-1
- EN 61000-6-2
- IEC 60533
- IEC 60601-1-2
- IEC 61326
- MIL STD 461
- RTCA/DO 160
- ISO 11452-2
- ISO 11452-3
- ISO 11452-4
- ISO 11452-5
- SAE J1113-4
- SAE J1113-24
All Accessories
Rent a variety of Conducted RF Immunity accessories with test solution.
Take advantage of A2LA ISO 17025 calibrations and fast deliveries!
Conducted RF Probes, Clamps, & DevicesItem | Capabilities |
EM101 | EM Clamp .15 to 1,000 MHz, 100 W max, incl: FTC 101 decoupling clamp |
F120-9A | Clamp-on injection probe, 10kHz to 230MHz, 125 CW, calibration fixture |
CDN-AF4 | 100v, 1.5amp. coupler for 4 unshielded lines |
CDN-S15 | 100V, 1.5 amp. CDN for 15 shielded lines |
CDN-M2/3/16A | 240VAC, 16A coupler for 2 or 3 power lines |
CDN-M5/32A |
400VAC, 32A coupler for 5 power lines |
Additional Available through Manufacturer |
|
MD 4070A | Monitoring Device 4kHz - 400MHz |
SW 4070, SW 4070-MAN | RF Switch NSG 4070 up to 2GHz |
ATN Series | 6 dB Attenuators |
Other Conducted RF Immunity Accessories
Item | Capabilities |
ATT6/75 | 6dB attenuator, 75W |
ATT20/0.5 | 20db attenuator, 0.5W for the calibration of CDNs and clamps (included with the PM 1000) |
CDNs | As per IEC 61000-4-6 (refer to separate list) |
Clamps | 50ohm termination resistor for CDNs and clamps |
T-50 | 240VAC, 16A coupler for 2 or 3 power lines |
R-100x |
150ohm-to-50ohm matching impedance for calibration |
Cal adapters |
For all types of CDNs and clamps |
icd.control | Extensive and most versatile remote control and reporting software. A standard library helps to configure the test setup. Multiple interruption functions automated by IEEE instruments or manually. Easy to use or expandable to complex test routines on the base of vector definitions. |
SW 4070, SW 4070-MAN | RF Switch NSG 4070 up to 2GHz |
ATN Series | 6 dB Attenuators |
Amplifiers/Models
Built in Amplifiers NSG 4070
There are a variety of different amplifier options that can be built into this conducted and radiated test solution. All of these Teseq amplifier built in these products are class A power amplifiers. These range from 260 Watts at the highest to 35 Watts at the lowest. All rental solutions from Transients Specialists come with either 75 Watt or 80 Watt built in amplifiers covering the 150kHz to 230Mhz frequency range for this generator. Below you will find the list of the amplifier watt choices and corresponding frequency ranges.
- 260 Watt Amplifier - 10 kHz (4 kHz) to 400 MHz
- 110 Watt Amplifier - 10 kHz (4 kHz) to 400 MHz
- 80 Watt Amplifier - 150 kHz to 230 MHz
- 60 Watt Amplifier - 10 kHz (4 kHz) to 400 MHz
- 45 Watt Amplifier - 9 kHz to 1 GHz
- 40 Watt Amplifier - 10 kHz to 400 MHz
- 35 Watt Amplifier - 150 kHz to 230 MHz