Solar 9354-2 - Transient Tester per MIL-STD-461 CS116 & DO-160 sec 22

Solar CS116 Pulse Generator

Solar 9354-2 - Transient Tester per MIL-STD-461 CS116 & DO-160 sec 22

Availability: In Stock - Order by 3PM Ships Today!

Militarily Conducted Immunity/Susceptibility Features 

      • DO-160 Waveforms 1,2,3A/3B, 4, 5A/5B
      • Damped Sinusoid Pules Generator
      • Frequency 10 & 100kHz, 1, 10, 30, 100MHz
      • Free Technical Support & 2 Days Free Transit
      • Double Exponential Pulse 6.4μs, 70μs, & 120μs
      • Single pulse feature controlled isolation of transient effects
      • Turnkey Solution - Arrives Ready for Testing!

Overview

The Solar 9354-2 by Solar Electronics is a specially designed transient generator designed for Military Conducted Susceptibility testing for MIL-STD-461 CS116 and DO-160 providing both damped sinusoid pulses and double exponential pulses. This pulse generator rental comes with an ISO 17025 accredited calibration and technical support. It provides six damped six damped sinusoidal pulses (10 kHz, 100 kHz, 1 MHz, 10 MHz, 30 MHz, and 100 MHz), three double exponential pulses (6.4 µS, 70 µS, 500 µS). It goes beyond the 9354-1 series and offer the three double exponential pulses, providing a more complete solution. 

The Solar 9354-2 includes a panel-mounted digital voltmeter that monitors the adjusted open circuit discharge voltage. The is military generator goes beyond the more basic 9354-1 and also has the capability for three double exponential pulses (6.4 µS, 70 µS, and 120 µS). Auto pulsing of the sinusoidal repetition rate is internally adjusted from 0.5 to 1.0 pulse per second.

It is a versatile Immunity test generator allowing for testing to MIL-STD-461 CS116 and RTCA DO-160 sec 22. A front panel-mounted push button can be used to manually trigger single pulses. The peak amplitude of the selected output pulse is adjustable as a percentage of the charge voltage. Our EMC rental equipment includes the option of renting the accessory Bulk Current Injection Clamp (BCI) and other accessories required for CS116.

Solar 9354 - CS115 & 116 Rentals

Militarily Conducted Immunity/Susceptibility Features 

      • DO-160 Waveforms 1,2,3A/3B, 4, 5A/5B
      • Damped Sinusoid Pules Generator
      • Frequency 10 & 100kHz, 1, 10, 30, 100MHz
      • Free Technical Support & 2 Days Free Transit
      • Double Exponential Pulse 6.4μs, 70μs, & 120μs
      • Single pulse feature controlled isolation of transient effects
      • Turnkey Solution - Arrives Ready for Testing!

Overview

The Solar 9354-2 by Solar Electronics is a specially designed transient generator designed for Military Conducted Susceptibility testing for MIL-STD-461 CS116 and DO-160 providing both damped sinusoid pulses and double exponential pulses. This pulse generator rental comes with an ISO 17025 accredited calibration and technical support. It provides six damped six damped sinusoidal pulses (10 kHz, 100 kHz, 1 MHz, 10 MHz, 30 MHz, and 100 MHz), three double exponential pulses (6.4 µS, 70 µS, 500 µS). It goes beyond the 9354-1 series and offer the three double exponential pulses, providing a more complete solution. 

The Solar 9354-2 includes a panel-mounted digital voltmeter that monitors the adjusted open circuit discharge voltage. The is military generator goes beyond the more basic 9354-1 and also has the capability for three double exponential pulses (6.4 µS, 70 µS, and 120 µS). Auto pulsing of the sinusoidal repetition rate is internally adjusted from 0.5 to 1.0 pulse per second.

It is a versatile Immunity test generator allowing for testing to MIL-STD-461 CS116 and RTCA DO-160 sec 22. A front panel-mounted push button can be used to manually trigger single pulses. The peak amplitude of the selected output pulse is adjustable as a percentage of the charge voltage. Our EMC rental equipment includes the option of renting the accessory Bulk Current Injection Clamp (BCI) and other accessories required for CS116.

Data SheetUser Manual

Common Standards

MIL-STD-461 CS116, RTCA DO-160 sec 22

Waveforms

Nine selectable waveforms including:

   10 kHz damped oscillatory

Open Circuit Voltage 30V

Calculated Short Circuit Current 120A

Source Impedance <.25 Ω

   100 kHz damped oscillatory

                                                   

Open Circuit Voltage 300V

Calculated Short Circuit Current 120A

Source Impedance <2.5 Ω

   1 MHz damped oscillatory

Open Circuit Voltage 3200V

Calculated Short Circuit Current 128A

Source Impedance <25 Ω


   10 MHz damped oscillatory

Open Circuit Voltage 3200V

Calculated Short Circuit Current 128A

Source Impedance <25 Ω

   30 MHz damped oscillatory

Open Circuit Voltage 1000V

Calculated Short Circuit Current 20A

Source Impedance <50 Ω

   100 MHz damped oscillatory

Open Circuit Voltage 300V

Calculated Short Circuit Current 6A

Source Impedance <50 Ω

   30 MHz damped oscillatory

Open Circuit Voltage 1000V

Calculated Short Circuit Current 20A

Source Impedance <50 Ω

   6.4µs double exponential

Open Circuit Voltage 1600V

Calculated Short Circuit Current 800A

Source Impedance <2Ω

Rise Time 100ns

   70µs double exponential

Open Circuit Voltage 1600V

Calculated Short Circuit Current 800A

Source Impedance <2Ω

Rise Time 6.4 µs

   120µs double exponential

Open Circuit Voltage 750V

Calculated Short Circuit Current 400A

Source Impedance <4Ω

Rise Time 40 µs

Repetition

.5 to 1 pulse per second, or manual trigger

Weight

25kg, 55 pounds

Dimensions

43.5cm X 33.0cm X 22.2cm (17.25” X 13” X8.75”)

Included with Rental Of Solar 9354-2

Below you will find a list of common accessories that you can expect to be delivered with the equipment. This is a generic standard list and should you require an exact connector or accessory please contact us prior to order shipping. We are also excited to offer many different testing accessories not standard with the transient generator. A detailed list of these can be found on the "All Accessories" tab. 

 

Solar 9354-2

    • Transient Generator
    • Power Cord
    • Printed Manual
    • Calibration Documentation 
    • Case

     

    Solar 9354 Full Accessory List
    Item Capabilities
    Variable Frequency Modules Provide tunable frequencies for injection of damped sinusoidal waveforms from 10 kHz to 100 MHz when used with Model 9354-1 or Model 9354-2. Five individual modules waveforms cover the entire frequency range required by MIL-STD-461E/F. Detailed information is provided on the Solar Type 9554-( ) Variable Frequency Modules page.
    Solar Type 9335-2 Multiple Impedance Coupling Clamp

    An inductive injection device that provides voltage and current transfer of 1:1, 1:1.5 and 1:3 voltage step-up (current step-down) as well as 2:1 voltage step-down (current step-up). For maximum power transfer, these ratios are selected by connecting to one of the four BNC connectors. This device, through its various connector ports, provides a better impedance match or power transfer, higher open circuit voltages, or higher short circuit currents. Recommended for cable current injection from 10 kHz to 1 MHz.

    Solar Type 2925-1 Calibration Fixture

    Calibration fixture provides a 50 Ω characteristic impedance based on the dimensions of the Type 9335-2 Coupling Clamp. The fixture maintains a low standing wave ratio from 10 kHz to 100 MHz in a 50 Ω circuit.

    Solar Type 9142-1N Injection Probe Recommended for cable current injection from 10 MHz to 100 MHz

    Solar Type 9125-1 Calibration Fixture

    Calibration fixture for use with Type 9142-1N Injection Probe.

    Solar Type 9123-1N Current Probe

    Used to monitor injected pulses of the 10 MHz, 30 MHz and 100 MHz outputs.

    Solar Type 9410-1 (50 Ω / 50 Ω) and Type 9454-1 (600 Ω / 50 Ω) High Voltage Attenuators

    Provide 40 dB attenuation from 10 kHz to 100 MHz. Protects oscilloscope from high voltage damage when verifying the output pulses of the 9354 series. The Solar Type 9454-1 provides a high impedance to the generator for making measurements of open circuit output pulses.

    Solar Type 6220-4 High Voltage Audio Isolation Transformer

    When connected in series with the power lead under test, provides twice the open circuit voltage or twice the short circuit current for the 10 kHz and 100 kHz damped sinusoid waves and the 70 µS double exponential pulse. Capable of handling up to 4000 V.

    Solar Type 9616-1 Injection Clamp

    Provides coupling for high voltage pulses produced by Models 9354-1 and Model 9354-2

      

    I would recommend Transient Specialists. Transient Specialists always provides quality products within the established timeframes. The equipment always meets the specifications and properly shipped within the time frames within the time frames promised.

    Scott D., TUV SUD Canada

     

    Transient Specialists has been outstanding at working with us for our specialized EMC equipment rental needs. Fast shipments and excellent accommodation for some customized setups. I recommend them highly and they are a pleasure to partner with!

    John H., Gates Air, Inc.

     

    Laura, I want to thank you and Goran for your excellent customer service and turn around time on the rentals and the calibration documents.  

    Adam P., Clark Testing

     

    Working for a testing company I deal with renting equipment all the time.  Transient Specialist is the first company I call on my list of rental houses because of their great personnel, prompt delivery of the equipment, knowledgeable and accommodating to the customers needs.

    Richard T., National Technical Systems

    Comparable EMC Systems

    Capabilities MIL-STD-461 CS115 MIL-STD-461 CS115 & CS116 MIL-STD-461 CS116 MIL-STD-461 CS115
    Manufacturer EMC Partner EMC Partner Solar Electronics Solar Electronics
    Waveforms 2x30us Waveforms 2x30us Waveforms & 6 Damped Waves 6 Damped Waves & 3 Double Exponential 2x30us Waveforms
    Accessories Some Included - See Packing List Some Included - See Packing List CS116 Accessory Package Available CS116 Accessory Package Available
    System Features EMC Partner Platform Controlled via Front Screen Front Screen Control & CS115/CS116 Single Box Single Standard Solution - Controlled via Turn Nob & Buttons Single Standard Solution - Controlled Turn Nob & Buttons