Keytek ECAT GR-1089-CORE Telecom Immunity System

Availability:
In Stock - Order By 3PM Ships Today!

Keytek ECAT GR-1089-CORE System:

  • GR-1089-CORE Solution - Telecom Test Systems
  • ECAT E103, E506-4W, E509, & E508
  • 10x360µs,10x1000µs, and 2x10µs Pulses
  • Current ISO 17025 Cal & 2 Days Free Transit Time

Get weekly, two week, and monthly rentals on all products

Got Questions about the equipment? Get technical support

Two FREE days transit time with every rental

Request A Quote

Common Immunity Accessories

Description

Conducted Immunity Generator Features 

      • GR-1089-CORE Solution - Telecom Test Systems
      • ECAT E103, E506-4W, E509, & E508
      • Free Technical Support & 2 Days Free Transit
      • This is a combined solution GR-1089-CORE
      • Turnkey Solution - Arrives Ready for Testing!

Overview

This ECAT Telecom Telecordia Lightning system made by Thermo Fisher Scientific / Keytek is designed for Immunity testing to a variety of standards having telecom 10x360µs,10x1000µs, and 2x10µs waveform requirements on multiple terminals. This Thermo Fisher Scientific EMC immunity test system comes with free technical support included with the rental. All of these ECAT modules rented together come with the ECAT E103 control unit for use.

This Immunity Test Equipment provides single port testing and allows changing tests modes without switching off power to the equipment under test (EUT). This helps testing with this telecom system to be conducted efficiently without re-initializing the EUT between tests. This telecommunications immunity testing system is a combination of the ECAT E103, ECAT E506-4W, ECAT E508, and ECAT E509 which can be rented separately.

This ECAT Telecommunications EMI Test equipment is designed to test to many requirements of GR-1089-CORE and and many other telecommunication based standards. This unit includes three two bay Telecordia / Bellcore testing modules and the E103 control unit. This ECAT EMC equipment combination can be controlled via front panel or through computer using Keytek software.

Data Sheet

Specifications

Controller-E103

Controller for the ECAT system with front panel and software operation.

Telecom Surge E506-4W

 

Standards

GR-1089-CORE

Waveforms

2x10µs,50-800V  100A/terminal with 800V OCV   

2x10µs,50-1500V  100A/terminal with 1500V OCV     

2x10µs, 100-2500V, 500A/terminal with 2500V OCV

2x10µs,200-5000V,  100A/terminal with 5000V OCV          

Peak Open Circuit Voltage

-0%/+20%

Peak Short Circuit Current

-0%/+20%


Pulse Repetition Rate

1 Shot/16 seconds

Weight

44kg, 97lb

Dimensions

21x42x52 cm , 8x16x20 inches

Telecom Surge E508

 

Standards

GR-1089-CORE

Open Circuit Voltage Waveform

10/360µs

Short Circuit Current Waveform

10/360µs

Peak Open Circuit Voltage

50-1100V,-0±15% in 1 voltage steps

Peak Short Circuit Current

100A/side

Pulse Repetition Rate

1 shot/50 seconds

Weight

11kg,25 lb

Dimensions

21x42x52cm, 8x16x20 inches

E509 Telecordia Lightening Surge

 

Standards

GR-1089-CORE

Open Circuit Voltage Waveform

10/1000µs, 50-600V -0/+15% peak

10/1000µs,50-1000V -0/+15%peak

10/1000µs,50-1500V -0/+15%peak

Short Circuit Current Waveform

100A/side -0/+15%peak

Duration

-0/+50% for Voltage

Front Time

-30%/+0 for Voltage

Pulse Repetition Rate

1 shot/40 seconds

Weight

16kg, 35 pounds

Dimensions

21x42x52 cm, 8x16x20 inches

ECAT Series

Common Modules

 

ECAT Series Full Accessory
Item Capabilities
ECAT Model E411 EFT/Noise Burst simulator for testing in accordance with IEC 61000-4-4 Edition 2 to 4.4kV
ECAT Model E412 EFT/Noise Burst simulator with built-in, single phase AC mains coupler/decoupler for testing in accordance with IEC 61000-4-4 Edition 2 to 4.4kV. Model E412 features all specifications and options noted in Model E411 (above), as well as the following:
ECAT Model E421 FT/Noise™ Burst Simulator for IEC 61000-4-4 Edition 2 to 8 k
ECAT Model E501B Plug-in combination wave surge simulator to produce the combination waves required by IEC 6100-4-5, ANSI/IEEE C62.41 Cat. B and UL 1449 at 3kA
ECAT Model E502B Plug-in module to produce the telecommunications surge wave required by IEC 61000-4-5, FCC Part 68 and ITU Rec K.17, K.20, and K.21 (formerly CCITT
ECAT Model E503 Plug-in module to produce the ring waves specified by ANSI/IEEE C62.41 Cat. A and B, and various UL standards, including UL 864
ECAT Model E504A Plug-in module to produce the combination wave required by UL 1449 (some devices must also be tested using the E501A surge module)
ECAT Model E505A Plug-in module that produces the lightning surge waveforms required by FCC Part 68
ECAT Model E506-4W Plug-in module to produce the 2/10 µs surges required by Telcordia GR-1089 CORE for up to five-wire (four terminal) testing
ECAT Model E508 and E508-12P Plug-in modules to produce the 10/360 µs surges required by Telcordia GR-1089 CORE
ECAT Model E510A Plug-in module to produce combination wave specified by ANSI/IEEE C62.41 Cat. B and IEC 61000 4-5 to 10kV and 5kA
ECAT Model E511 Plug-in module to provide combination waves to 6 kV and 5 kA, as required by British Telecom standards
ECAT Model E513 Plug-in module to produce voltage ramps for testing surge protection components such as gas tube arrestors; meets surge simulator requirements of UL 864
ECAT Model E514 Surge simulator for 10/1000 µs current waves
ECAT Model E515 Module to produce the 10/250 µs surges required by Telcordia GR-1089-CORE
ECAT Model E518 Plug-in module to produce the 10/1000µs waveforms to 2kV as required by Telcordia GR-1089-CORE for both Lightning Surge and Protection Coordination. Includes HB-ECAT
ECAT Models E521 and E522 Surge systems that produce the high voltage, high current combination waves required by ANSI standards for service entrance and outside connected electronics; meets requirements of IEC 61000-4-5 for all exposure categories. ECAT Model E521 includes built-in AC coupler/decoupler for singlephase lines to 480V, 32A; ECAT Model E522 includes built-in AC coupler/decoupler for three-phase lines to 480V, 32A/phase (actual AC mains current per AC line connector limits).
ECAT Model E551 A single-phase AC line (power lines) coupler/decoupler for surge waves, as specified by IEC 61000-4-5
ECAT Models EP61 and EP62 Plug-in modules provide swells, dips and interrupts on AC power mains in compliance with, and exceeding the requirements of IEC 61000-4-11 Edition 2. Model EP61 for single-phase AC lines to 240 RMS, 16A; Model EP62 for single-phase AC lines to 240 RMS, 32A
ECAT Model E455x Single and three-phase AC line coupler/decouplers for EFT and Surge waves, as specified by IEC 61000-4-4 Edition 2 and IEC 61000-4-5

  

You may also like