EM Test CNV 504N1.3 - Unsymmetrical Unshielded CDN

Signal/Data Line CDN

EM Test CNV 504N1.3 - Unsymmetrical Unshielded CDN

Availability: In Stock - Order by 3PM Ships Today!

EM Test Coupling/Decoupling Network Features 

      • CDN for IEC/EN 61000-4-5 & IEC/EN 61000-4-12
      • ISO 17025 Accredited Calibration included
      • Used for Unsymmetrical/Unshielded Datelines 
      • Free Technical Support & 2 Days Free Transit
      • Test voltage up to 4 kV, 7 kV and 10 kV
      • 20 mH decoupling inductor per line

Overview

EMTest CNV504N1.3 coupling/decoupling networks for unshielded  unsymmetrical interconnection signal/data lines. Surge pulses or Ringwave pulses are applied to unshielded unsymmetrical interconnected lines by means of standalone coupling/decoupling networks for 4 signal/data lines. CNV 504 N1.3 combines three different applications; coupling of Surge pulse via capacitor or gas arrestor and coupling of Ringwave pulses via capacitor being required by EN IEC 61000-4-5 and/or EN IEC 61000-4-12.

The required coupling mode, Differential or Common, can easily be selected by means of a simple jumper. In accordance with EN IEC 61000-4-5 and EN IEC 61000-4-12 pulses are coupled via different coupling elements such as capacitors or gas arrestors depending on the characteristics of the line signals.

Data/Telecom CDN Equipment

EM Test Coupling/Decoupling Network Features 

      • CDN for IEC/EN 61000-4-5 & IEC/EN 61000-4-12
      • ISO 17025 Accredited Calibration included
      • Used for Unsymmetrical/Unshielded Datelines 
      • Free Technical Support & 2 Days Free Transit
      • Test voltage up to 4 kV, 7 kV and 10 kV
      • 20 mH decoupling inductor per line

Overview

EMTest CNV504N1.3 coupling/decoupling networks for unshielded  unsymmetrical interconnection signal/data lines. Surge pulses or Ringwave pulses are applied to unshielded unsymmetrical interconnected lines by means of standalone coupling/decoupling networks for 4 signal/data lines. CNV 504 N1.3 combines three different applications; coupling of Surge pulse via capacitor or gas arrestor and coupling of Ringwave pulses via capacitor being required by EN IEC 61000-4-5 and/or EN IEC 61000-4-12.

The required coupling mode, Differential or Common, can easily be selected by means of a simple jumper. In accordance with EN IEC 61000-4-5 and EN IEC 61000-4-12 pulses are coupled via different coupling elements such as capacitors or gas arrestors depending on the characteristics of the line signals.

Data SheetUser Manual

Common Standards

EN IEC 61000-4-5 & EN IEC 61000-4-12

No. of Lines

4 Unshielded unsymmetrical interconnection lines

Test Voltage Max

Up to 4kV

Line Voltage Max.

250 VAC, 300 VDC

Coupling/Decoupling

4 kV coupling/ decoupling network line current 4 A, intermittent 5 A 


Decoupling Inductance

20 mH, each line

Surge coupling

per EN IEC 61000-4-5 Ed. 3, -0.5 µF capacitor via 40 ohm

Ringwave coupling

per EN IEC 61000-4-12 Ed. 2, -3.3 µF capacitor

Dimension and Weight

330 x 230 x 112 mm, 9.75KG