Description
Overview
Rent and buy the E103 by Thermo Fisher Scientific/Keytek is part of the 100 series control centers required for the operation of the ECAT testing system. This computer control has easy to use interface with LCD screen and keyboard entry system. This control center allows for multiple bay attachments for additional testing capabilities.
This system comes with a single bay, software, and fibercom box and cable for connection to a computer. This series of module is the latest model of the series of control units produced by Thermo Keytek. This module has the advantage over the rest of the E100 series of providing surge V&I monitoring ports.
The ECAT test control center does not include any networks or other modules. The E103 system facilitates testing for a variety of modules and module combinations. This cost effective solution is in excellent working conduction and software can acquired with purchase.
ECAT Series - Data SheetSpecifications
E103 Controller |
|
Virtual Front Panel Control |
8 X 40 character keyboard entry and LCD display |
FiberCom Fiber-optic Interface and Control System |
Uses ECAT software for full computer control of ECAT test equipment |
Surge V and I Monitor Ports | For waveform monitoring with an external (user-supplied oscilloscope) at 1kV/V and 200A/V;V & I signals suppled from optional AC Coupler/decoupler or ECAT modules/options |
Input Voltage |
100V to 240 VAC, 50/60 Hz |
Typical Input Current |
3.5A @ 100V; 1.5A @ 240V |
Weight |
15.6 kg , 55 lbs |
Dimensions |
58.42 X 23.18 X 13.97 cm, 23 X 17 X 5 1/2 inches
|
ECAT Series
Common Modules
ECAT Series Full Accessory
Item | Capabilities |
ECAT Model E411 | EFT/Noise Burst simulator for testing in accordance with IEC 61000-4-4 Edition 2 to 4.4kV |
ECAT Model E412 | EFT/Noise Burst simulator with built-in, single phase AC mains coupler/decoupler for testing in accordance with IEC 61000-4-4 Edition 2 to 4.4kV. Model E412 features all specifications and options noted in Model E411 (above), as well as the following: |
ECAT Model E421 | FT/Noise™ Burst Simulator for IEC 61000-4-4 Edition 2 to 8 k |
ECAT Model E501B | Plug-in combination wave surge simulator to produce the combination waves required by IEC 6100-4-5, ANSI/IEEE C62.41 Cat. B and UL 1449 at 3kA |
ECAT Model E502B | Plug-in module to produce the telecommunications surge wave required by IEC 61000-4-5, FCC Part 68 and ITU Rec K.17, K.20, and K.21 (formerly CCITT |
ECAT Model E503 | Plug-in module to produce the ring waves specified by ANSI/IEEE C62.41 Cat. A and B, and various UL standards, including UL 864 |
ECAT Model E504A | Plug-in module to produce the combination wave required by UL 1449 (some devices must also be tested using the E501A surge module) |
ECAT Model E505A | Plug-in module that produces the lightning surge waveforms required by FCC Part 68 |
ECAT Model E506-4W | Plug-in module to produce the 2/10 µs surges required by Telcordia GR-1089 CORE for up to five-wire (four terminal) testing |
ECAT Model E508 and E508-12P | Plug-in modules to produce the 10/360 µs surges required by Telcordia GR-1089 CORE |
ECAT Model E510A | Plug-in module to produce combination wave specified by ANSI/IEEE C62.41 Cat. B and IEC 61000 4-5 to 10kV and 5kA |
ECAT Model E511 | Plug-in module to provide combination waves to 6 kV and 5 kA, as required by British Telecom standards |
ECAT Model E513 | Plug-in module to produce voltage ramps for testing surge protection components such as gas tube arrestors; meets surge simulator requirements of UL 864 |
ECAT Model E514 | Surge simulator for 10/1000 µs current waves |
ECAT Model E515 | Module to produce the 10/250 µs surges required by Telcordia GR-1089-CORE |
ECAT Model E518 | Plug-in module to produce the 10/1000µs waveforms to 2kV as required by Telcordia GR-1089-CORE for both Lightning Surge and Protection Coordination. Includes HB-ECAT |
ECAT Models E521 and E522 | Surge systems that produce the high voltage, high current combination waves required by ANSI standards for service entrance and outside connected electronics; meets requirements of IEC 61000-4-5 for all exposure categories. ECAT Model E521 includes built-in AC coupler/decoupler for singlephase lines to 480V, 32A; ECAT Model E522 includes built-in AC coupler/decoupler for three-phase lines to 480V, 32A/phase (actual AC mains current per AC line connector limits). |
ECAT Model E551 | A single-phase AC line (power lines) coupler/decoupler for surge waves, as specified by IEC 61000-4-5 |
ECAT Models EP61 and EP62 | Plug-in modules provide swells, dips and interrupts on AC power mains in compliance with, and exceeding the requirements of IEC 61000-4-11 Edition 2. Model EP61 for single-phase AC lines to 240 RMS, 16A; Model EP62 for single-phase AC lines to 240 RMS, 32A |
ECAT Model E455x | Single and three-phase AC line coupler/decouplers for EFT and Surge waves, as specified by IEC 61000-4-4 Edition 2 and IEC 61000-4-5 |