ECAT E103, E502b - Telecom 10x700 Surge Test System

RENTAL

ECAT E103, E502b - Telecom 10x700 Surge Test System

Thermo Keytek ECAT Telecom Test system with the E502b, 10x700 or 9x720 microsecond surge generator for ITU k.17, k.20, k.21



Thermo Keytek ECAT Telecom Test system with the E502b, 10x700 or 9x720 microsecond surge generator for ITU k.17, k.20, k.21

 

Controller-E103

Controller for the ECAT system with front panel and software operation.

Telecom Surge E502b

 

Standards

IEC 61000-4-5, EN 61000-4-5, FCC part 68, ITU-T k.20, k.21,k.44 – also meets the 9x720 requirement

Open Circuit Voltage Waveform

10µs  Front Time - Tolerance 7 to 11.7µs.

700µs Duration – Tolerance  576 µs to 840 µs

Short Circuit Current Waveform

5µ Front Time ±  30%, 320µs Duration ± 20%

Peak Open Circuit Voltage

200V–6.6kV ± 10% @15 Ω or @40 Ω

Peak Short Circuit Current

OCV÷15 with 0 ohm eff.imped., OCV ÷40 with 25 ohm eff. Imped.  Tolerance -0/+10%

Repetition Rate

3 impulse per min @ 6kV

Weight

11 kg, 25 pounds

Dimensions

21x21x52 cm, 8x8x20 inches