ECAT E103, E513 - EMC Immunity Voltage Ramp Generator per UL 864 & Others

RENTAL

ECAT E103, E513 - EMC Immunity Voltage Ramp Generator per UL 864 & Others

Thermo Keytek ECAT System with the E513 voltage ramp generator for testing per UL 864, UL 294 and many others.



Thermo Keytek ECAT System with the E513 voltage ramp generator for testing per UL 864, UL 294 and many others.

 

Controller-E103

Controller for the ECAT system with front panel and software operation.

Telecom Surge E513

 

Standards

UL 864, UL 294

Open Circuit Voltage Ramps

0.1kV/µs,0.5kV/µs,1.0kV/µs,5.0kV/µs,10kV/µs0.1kV/µs is linear to 2.5kV; all other ramps are linear to 3.0kV.

Voltage Durations

65µs for 0.1kV/µs

40µs for 0.5 kV/µs and 1.0kV/µs 5µs for 5kV/µsand 10kV/µs

Current Duration

45 µs at 0.1kV/µs

40µs at 0.5kV/µs and 1.0kV/µs

4µs at 5kV/µs and 10kV/µs

Open-Circuit Voltage

0-3000V±5% in 1 volt steps

Short-Circuit Current

50A ±10% when the peak open-circuit voltage is set to 3.0kV

Weight

53kg (24lbs)

Dimensions

21 X 52 X 21cm (8  ¼ X 20 3/8 X 8 ¼)