ECAT E103, EP62 - Dips and Interrupts EMC Immunity Testing per IEC 61000-4-11

RENTAL

ECAT E103, EP62 - Dips and Interrupts EMC Immunity Testing per IEC 61000-4-11

Thermo Keytek ECAT System with the EP62 Dips and Interrupts module for single phase 277V, 32A equipment per IEC 61000-4-11



Thermo Keytek ECAT System with the EP62 Dips and Interrupts module for single phase 277V, 32A equipment per IEC 61000-4-11

 

Controller-E103

Controller for the ECAT system with front panel and software operation.

EP62 Swell/Dip/Interrupt (PQF)Module

 

Standards

IEC 61000-4-11

Input Voltages for 100%

50 to 240 at 50Hz and to 277 at 60Hz

Output Voltages on the Selected Phase

0%(open or short),40%,50%,70%,80%,90%,100%,110%,120%, and 150%

Output Current

32A at 250V; 30A at 125V

Inrush Current

>250A at 120V; >500A at 220 to 240V

Event Duration

From .03 cycle(10°) to 500 minutes; maximum 12 events per cycle.

Switching Times

1 to 5µs into a 100 ohm load

Weight

24.7kg, 87 pounds

Dimensions

21x42x52 cm, 8 1/4 x 16 ½  x 20  3/8inches