ECAT E103, EP62, EP3 3-Phase Dips and Interrupts per Ed. 1

RENTAL

ECAT E103, EP62, EP3 3-Phase Dips and Interrupts per Ed. 1

Thermo Keytek ECAT system with the EP62 and the semi-manual EP3 for dips and interrupts testing on a 3 phase EUT per ed.1 of IEC 61000-4-11



Thermo Keytek ECAT system with the EP62 and the semi-manual EP3 for dips and interrupts testing on a 3 phase EUT per ed.1 of IEC 61000-4-11

 

Controller-E103

Controller for the ECAT system with front panel and software operation.

EP62 Swell/Dip/Interrupt (PQF)Module

 

Standards

IEC 61000-4-11

Input Voltages for 100%

50 to 240 at 50Hz and to 277 at 60Hz

Output Voltages on the Selected Phase

0%(open or short),40%,50%,70%,80%,90%,100%,110%,120%, and 150%

Output Current

32A at 250V;30A at 125V

Inrush Current

>250A at 120V;>500A at 220 to 240V

Event Duration

From .03 cycle(10°) to 500 minutes; maximum 12 events per cycle.

Switching Times

1 to 5µs into a 100 ohm load

Weight

24.7kg, 87 pounds

Dimensions

21x42x52 cm, 8 1/4 x 16 ½  x 20  3/8inches

EP3 3 phase coupler for the EP62

 

Voltage

Max voltage 480V, 32A

Standards

IEC 6100-4-11

Dimensions

21x42x52 cm, 8 1/4 x 16 ½  x 20  3/8inches