ECAT E502B - ECAT Module For The 10x700 Microsec. Telcom Surge Test

RENTAL

ECAT E502B - ECAT Module For The 10x700 Microsec. Telcom Surge Test

Thermo Keytek E502B telecom surge module performs the 10x700 microsecond telecom surge to 6kV.  It also satisfies the 9x720 telecom surge test.  It requires the E103 controller in order to function



Thermo Keytek E502B telecom surge module performs the 10x700 microsecond telecom surge to 6kV.  It also satisfies the 9x720 telecom surge test.  It requires the E103 controller in order to function

Telecom Surge E502b

 

Standards

IEC 61000-4-5, EN 61000-4-5, FCC part 68, ITU k.17, k.20,k.21 – also meets the 9x720 requirement

Open Circuit Voltage Waveform

10µs  Front Time - Tolerance 7 to 11.7µs.

700µs Duration – Tolerance  576 µs to 840 µs

Short Circuit Current Waveform

5µ Front Time ±  30%, 320µs Duration ± 20%

Peak Open Circuit Voltage

200V–6.6kV ± 10% @15 Ω or @40 Ω

Peak Short Circuit Current

OCV÷15 with 0 ohm eff.imped., OCV ÷40 with 25 ohm eff. Imped.  Tolerance -0/+10%

Repetition Rate

3 impulse per min @ 6kV

Weight

11 kg, 25 pounds

Dimensions

21x21x52 cm, 8x8x20 inches