Keytek ECAT E508 - Bellcore 10x360µs Telecom Surge

GR-1089 10x360µs Module

Keytek ECAT E508 - Bellcore 10x360µs Telecom Surge

Availability: In Stock - Order by 3PM Ships Today!

Coupler/Decoupler Features: 

      • 10x360µs 50-1100V per GR-1089-CORE
      • ISO 17025 Calibration Included
      • Surges for Telecom testing for Bellcore
      • Can Be Rented w/without E103 System
      • Free Technical Support & 2 Days Free Transit
      • Must be Used with ECAT E103 Controller

Overview

The ECAT E508 module made by Thermo Fisher Scientific / Keytek is designed for Immunity testing to a variety of standards having telecom 10x360µs waveform requirements. This Thermo Fisher Scientific EMC immunity test equipment comes with free technical support included with the rental. The ECAT E 508 plug-in module requires the ECAT E103 control unit for use.

This Thermo Fisher Scientific / Keytek EMC Test Equipment provides single port testing and allows changing tests modes without switching off power to the equipment under test (EUT). This helps testing with the E508 to be conducted efficiently without re-initializing the EUT between tests. The ECAT E103 is required for use and both units can be rented as an ECAT E103, E506-4W, E508, & E509 Telecom EMC immunity test system. 

The ECAT E508 is designed to test GR-1089-CORE and and many other telecommunication based standards. This unit can be easily integrated with preexisting ECAT system by sliding the E508 into open bay of the ECAT E103 control unit. The E103 and E508 combination can be controlled via front panel or through computer using Keytek software.

Keytek ECAT - Test Accessories

Coupler/Decoupler Features: 

      • 10x360µs 50-1100V per GR-1089-CORE
      • ISO 17025 Calibration Included
      • Surges for Telecom testing for Bellcore
      • Can Be Rented w/without E103 System
      • Free Technical Support & 2 Days Free Transit
      • Must be Used with ECAT E103 Controller

Overview

The ECAT E508 module made by Thermo Fisher Scientific / Keytek is designed for Immunity testing to a variety of standards having telecom 10x360µs waveform requirements. This Thermo Fisher Scientific EMC immunity test equipment comes with free technical support included with the rental. The ECAT E 508 plug-in module requires the ECAT E103 control unit for use.

This Thermo Fisher Scientific / Keytek EMC Test Equipment provides single port testing and allows changing tests modes without switching off power to the equipment under test (EUT). This helps testing with the E508 to be conducted efficiently without re-initializing the EUT between tests. The ECAT E103 is required for use and both units can be rented as an ECAT E103, E506-4W, E508, & E509 Telecom EMC immunity test system. 

The ECAT E508 is designed to test GR-1089-CORE and and many other telecommunication based standards. This unit can be easily integrated with preexisting ECAT system by sliding the E508 into open bay of the ECAT E103 control unit. The E103 and E508 combination can be controlled via front panel or through computer using Keytek software.

Data Sheet

E508 Telecom Surge Module 

 

Standards

GR-1089-CORE

Open Circuit Voltage Waveform

10/360µs

Short Circuit Current Waveform

10/360µs

Peak Open Circuit Voltage

50-1100V,-0±15% in 1 voltage steps

Peak Short Circuit Current

100A/side

Pulse Repetition Rate

1 shot/50 seconds

Weight

11kg,25 lb

Dimensions

21x42x52cm, 8x16x20 inches

I would recommend Transient Specialists. Transient Specialists always provides quality products within the established timeframes. The equipment always meets the specifications and properly shipped within the time frames within the time frames promised.

Scott D., TUV SUD Canada

 

Transient Specialists has been outstanding at working with us for our specialized EMC equipment rental needs. Fast shipments and excellent accommodation for some customized setups. I recommend them highly and they are a pleasure to partner with!

John H., Gates Air, Inc.

 

Laura, I want to thank you and Goran for your excellent customer service and turn around time on the rentals and the calibration documents.  

Adam P., Clark Testing

 

Working for a testing company I deal with renting equipment all the time.  Transient Specialist is the first company I call on my list of rental houses because of their great personnel, prompt delivery of the equipment, knowledgeable and accommodating to the customers needs.

Richard T., National Technical Systems