EM Test CCI - Rent Capacitve Clamp EFT/Burst Testing

EM Test Coupling Clamp

EM Test CCI - Rent Capacitve Clamp EFT/Burst Testing

Ametek Coupling Clamp

      • Construction as per IEC 61000-4-4 Ed.3
      • EFT/Burst testing of signal- and datalines
      • Permissible burst voltage 7 kV
      • Can Work With Many Immunity Generators!
      • For cable diameter up to 40 mm

 

Overview

The EM test CCI capacitive coupling clamp is an ideal solution for testing electrical fast transients/burst onto data lines. This accessory is designed for use with the EM Test series of generators including the UCS 200N and NX series. The clamp, however can also be used with a variety of generators depending upon the type of connection that is required. The IEC 61000-4-4 Ed 3.0 published 2012 recomends the calibration of the capacitive coupling clamp into a 50ohm coaxial load with the normative calibration kit CCI PVKIT 1.

The coupling of the Electrical Fast Transients EFT/burst to signal lines can usually not be achieved by discrete capacitive coupling without interfering with the signal flow The interference simulator can be connected on both sides of the coupling clamp.

Ametek Coupling Clamp

      • Construction as per IEC 61000-4-4 Ed.3
      • EFT/Burst testing of signal- and datalines
      • Permissible burst voltage 7 kV
      • Can Work With Many Immunity Generators!
      • For cable diameter up to 40 mm

 

Overview

The EM test CCI capacitive coupling clamp is an ideal solution for testing electrical fast transients/burst onto data lines. This accessory is designed for use with the EM Test series of generators including the UCS 200N and NX series. The clamp, however can also be used with a variety of generators depending upon the type of connection that is required. The IEC 61000-4-4 Ed 3.0 published 2012 recomends the calibration of the capacitive coupling clamp into a 50ohm coaxial load with the normative calibration kit CCI PVKIT 1.

The coupling of the Electrical Fast Transients EFT/burst to signal lines can usually not be achieved by discrete capacitive coupling without interfering with the signal flow The interference simulator can be connected on both sides of the coupling clamp.

Data Sheet

Common Standards

EN/IEC 61000-4-4

Max. permissible burst voltage

7 kV

Dimension Coupling plate

140 mm x 1000 mm

Height

GND - Coupling plate, 100 mm

Connector

High voltage connector, coaxial

GND connection

4 mm plug, banana

EUT cable

up to 40 mm diameter

Weight

10.6 kg

I would recommend Transient Specialists. Transient Specialists always provides quality products within the established timeframes. The equipment always meets the specifications and properly shipped within the time frames within the time frames promised.

Scott D., TUV SUD Canada

 

Transient Specialists has been outstanding at working with us for our specialized EMC equipment rental needs. Fast shipments and excellent accommodation for some customized setups. I recommend them highly and they are a pleasure to partner with!

John H., Gates Air, Inc.

 

Laura, I want to thank you and Goran for your excellent customer service and turn around time on the rentals and the calibration documents.  

Adam P., Clark Testing

 

Working for a testing company I deal with renting equipment all the time.  Transient Specialist is the first company I call on my list of rental houses because of their great personnel, prompt delivery of the equipment, knowledgeable and accommodating to the customers needs.

Richard T., National Technical Systems