EMC Pro Plus & CCL Rental - Keytek Immunity Test System

EMCPro & CCL Immunity Tester

EMC Pro Plus & CCL Rental - Keytek Immunity Test System

Availability: In Stock - Order by 3PM Ships Today!

Conducted Immunity System Features 

      • 6kV Surge, 4.4kV EFT, 6kV Ringwave, & Dips
      • Upgraded Units & ISO 17025 Calibrations
      • Single Phase - 250v/16a AC & 100v/10a DC
      • Free Technical Support & 2 Days Free Transit
      • System Includes Thermo Keytek CCL
      • Front Current & Voltage Attenuated Monitoring Ports 
      • Turnkey Solution - Arrives Ready for Testing!

Overview

This test system, the EMCpro Plus and the capacitive coupling clamp (CCL), 6kV surge/combination wave, 4.4kV EFT/Burst, 100kHz ringwave at 6kV, and dips testing. The test generator comes with an ISO 17025 accredited calibration. This system is for the EMC Pro Plus the CCL as complete test setup. The components can be rented individually or as a single unit solution. We also offer rentals of the 10x700 Telecom wave board providing capabilities with the EMC Pro Plus platform. Data SheetUser ManualApplication Guide - CDNs

EMCPro Plus - Testing Accessories

Conducted Immunity System Features 

      • 6kV Surge, 4.4kV EFT, 6kV Ringwave, & Dips
      • Upgraded Units & ISO 17025 Calibrations
      • Single Phase - 250v/16a AC & 100v/10a DC
      • Free Technical Support & 2 Days Free Transit
      • System Includes Thermo Keytek CCL
      • Front Current & Voltage Attenuated Monitoring Ports 
      • Turnkey Solution - Arrives Ready for Testing!

Overview

This test system, the EMCpro Plus and the capacitive coupling clamp (CCL), 6kV surge/combination wave, 4.4kV EFT/Burst, 100kHz ringwave at 6kV, and dips testing. The test generator comes with an ISO 17025 accredited calibration. This system is for the EMC Pro Plus the CCL as complete test setup. The components can be rented individually or as a single unit solution. We also offer rentals of the 10x700 Telecom wave board providing capabilities with the EMC Pro Plus platform. Data SheetUser ManualApplication Guide - CDNs

Common Standards

EN/IEC 61000-4-4, EN/IEC 61000-4-5, EN/IEC 61000-4-11,

EN/IEC 61000-4-12, CEMark, ANSI IEEE C62.41 cat. B

Integrated CDN:

 

  AC Voltage and Current              

50-250 VAC, 16A max AC @250V

  DC Voltage and Current

100 VDC max, 10A max to 100V, 16A max to 48V


EFT Burst 5/50ns:

 

  Standards

IEC 61000-4-4, ed.3

  Voltage Waveform into 50Ω load

5ns Rise Time +/-1.5ns,  50µs pulse width +/-15ns

  Voltage Waveform into 1000Ω load

5ns Rise Time +/-1.5ns,  50µs pulse width +/-15ns

  Voltage Amplitude

+/- 125V – 2kV into 50Ω, +/-240-4kV into 1000Ω

  Burst Duration

15ms+/- 3ms@5kHz, .75ms +/- .15ms @100kHz

  Burst Period

300ms +/- 60ms

  Frequency

1-100 kHz, in .5k Hz steps, +/- 10%

Combination Wave Surge:

 

  Standards

IEC 61000-4-5 ed. 3, EN 61000-4-5, ANSI C62.41.2 Cat A& B, UL 1449 ed. 3 sec. 37, ANSI C62.45

  Open Circuit Voltage Waveform

1.2µs Front Time +/- 30%,  50µs Duration +/- 20%

  Short Circuit Current Waveform

8µ Front Time +/- 20%, 20µs Duration +/- 20%

  Peak Open Circuit Voltage

250V–6kV +/- 10% @2 Ω,  20.8-500A +/- 10%@12 Ω

  Peak Short Circuit Current

125A–3kA +/-10%@2 Ω, 20.8-500A +/-10%@12Ω

  Pulse Repetition Rate

2 pulses/min @6kV

100 kHz Ringwave:

 

  Standards

IEC 61000-4-12, EN 61000-4-12, ANSI C62.41.2 Cat A& B,   ANSI C62.45

  Open Circuit Voltage Waveform

100kHz Damped Cosine, risetime=.5µs+/-30%,

Damping= 40%/peak

  Peak Open Circuit Voltage

250V–6kV +/- 10% @12 Ω or @ 30 Ω

  Peak Short Circuit Current

200A +/-10%@30 Ωohms,500A +/-10%@12 Ω

  Pulse Repetition Rate

Up to 2 pulses /min@6kV

Telecom 10x700:

Optional – can only have Ringwave or Telecom

  Standards

IEC 61000-4-5, EN 61000-4-5, TIA-968-B, ITU k.44, k.45.

  Open Circuit Voltage Waveform

10µs Front Time +/- 30%, 700µs Duration +/- 20%

  Short Circuit Current Waveform

5µ Front Time +/- 20%, 320µs Duration +/- 20%

  Peak Open Circuit Voltage

250V–6kV +/- 10% @15 Ω or @40 Ω

  Peak Short Circuit Current

6.25-150A +/-10%@40 ohms – external 25Ω

  Repetition Rate

1 impulse per min @ 6kV

Dips and Interrupts:

 

  Standards

IEC 61000-4-11, Ed.2

  Voltage Dips:

40%, 70%, 80% residual voltage +/-5%

  Short Interrupts

0% residual voltage +/-5%

  Transition Time

Risetime, falltime ≥1µs & ≤5µs

  Input Voltage/Current

50-250VAC, 50/60Hz, 16A Max.

Weight

39kg, 85 pounds

Dimensions

23 x 43 x 65 cm, 8 x 17x26 inches

Included with Rental Of The EMC Pro Plus

Below you will find a list of common accessories that you can expect to be delivered with the equipment. This is a generic standard list and should you require an exact connector or accessory please contact us prior to order shipping. We are also excited to offer many different testing accessories not standard with the immunity generator.

 

EMC ProPlus

    • Conducted Immunity System
    • EUT Power Cord In
    • EFT Grounding Bracket
    • 10A250V plug
    • (4) Safety Plugs
    • Interlock Plug
    • Square EUT Connector
    • EMC-Pro Software
    • FC-11 Fibercom Converter
    • 10m. Fibercom Cable
    • RS232 C-11 Cable
    • Printed Manual
    • Serial to USB
    • Software
    • Calibration Documentation
    • Shipping Case 
EMCPro Plus Full Accessory List
Coupler Capabilities
CCL Capacitive Coupling Clamp conforming to IEC 61000-4-4
CCLC

Capacitive Coupling Clamp Cover

PK1001D

Differential High Voltage Probes

CM-3CD-Surge/32 Three phase, 32A External CDN for Surge Testing

CM-I/OCD

External 8-wire coupler/decoupler for I/O signal lines

EFT-ATTN-CAL

Eor EFT verification: Set of one 50Ω and one 1000Ω precision loads having >400MHz BW, one 20dB Attenuator with 1GHz BW

CCL-VERIFY

Manual 3-phase coupler for Surge (8 kV) only (combination and ring wave) with EUT current up to 100 A / 200 A

Models:

All of the Thermo Fisher EMC Pro equipment we carry are upgraded to the latest version of the associated standards and have the Plus distinction. This allows our customers the reassurance that the test generator provides the required waveforms. Below is a list of different models available through Thermo Keytek.

  • PRO-BASE
  • PRO-EFT
  • PRO-SURGE
  • PRO-TELECOM
  • PRO-RING
  • PRO-PQF
  • PRO-HPOWER
  • PRO-HPULSE

 

Standards:EMC Pro Plus Standards Reference Chart

Surge/Combination Wave

  • IEC 61000-4-5 Ed. 3
  • EN 61000-4-5
  • ANSI C62.41.2 Cat A & B
  • UL 1449 Ed. 3 Sect. 37
  • ANSI C62.45

PQF/Dips

  • IEC 61000-4-11

 

Ring Wave - Surge

  • ANSI C62.41.2, Cat A, B
  • IEC 61000-4-12
  • EN 61000-4-12
  • ANSI C62.45

I would recommend Transient Specialists. Transient Specialists always provides quality products within the established timeframes. The equipment always meets the specifications and properly shipped within the time frames within the time frames promised.

Scott D., TUV SUD Canada

 

Transient Specialists has been outstanding at working with us for our specialized EMC equipment rental needs. Fast shipments and excellent accommodation for some customized setups. I recommend them highly and they are a pleasure to partner with!

John H., Gates Air, Inc.

 

Laura, I want to thank you and Goran for your excellent customer service and turn around time on the rentals and the calibration documents.  

Adam P., Clark Testing

 

Working for a testing company I deal with renting equipment all the time.  Transient Specialist is the first company I call on my list of rental houses because of their great personnel, prompt delivery of the equipment, knowledgeable and accommodating to the customers needs.

Richard T., National Technical Systems

Comparable EMC Systems

Capabilities & Voltage 6.6kV Combination Wave, 4.8kV EFT, & 6.6kV Ringwave 6kV Combination Wave, 4.4kV EFT, 6kV Ringwave, & 50-250VAC Dips Interrupts, 7kV Combination Wave, 5kV EFT, & 7kV Ringwave 7kV Combination Wave, 5.5kV EFT, & 6kV Ringwave
Standards (IEC) IEC 61000-4-5, IEC 61000-4-4, & IEC 61000-4-12 IEC 61000-4-5, IEC 61000-4-4, IEC 61000-4-11, & IEC 61000-4-12 IEC 61000-4-5, IEC 61000-4-4, & IEC 61000-4-12 IEC 61000-4-5, IEC 61000-4-4, & IEC 61000-4-12
Built-in Coupler CDN 3061 - 270V/16Amp AC/DC 250V/16Amp AC 100V/10Amp DC 264V/16Amp AC/DC & 220V/10Amp AC/DC 300V/16Amp AC 300V/10Amp DC
Rental CDNs 1 & 3-Phase Automatic 1-Phase Auto & 3-Phase Manual (EFT) 1 & 3-Phase Automatic 1-Phase Auto & 3-Phase Manual (EFT)
Additional Features Many Rental CDNs Available & Easy to Use 10X700 Telecom to 6kV & Built-in Dips Interrupts Voltage/Current Monitoring on Front EM Test Solution 300V 1-Phase Coupler