NSG3060 CDN3063 - EFT to 4.8kV, Surge and Ringwave to 6.6kV, Includes 3 Phase Coupler

RENTAL

NSG3060 CDN3063 - EFT to 4.8kV, Surge and Ringwave to 6.6kV, Includes 3 Phase Coupler

Teseq EMC Immunity Tester for EFT to 4.8kV, Surge to 6.6kV, 100 kHz Ringwave to 6.6kV.  Includes the CDN 3063, three phase EFT and Surge coupler with 480V, 32A EUT capability



Teseq EMC Immunity Tester for EFT to 4.8kV, Surge to 6.6kV, 100 kHz Ringwave to 6.6kV.  Includes the CDN 3063, three phase EFT and Surge coupler with 480V, 32A EUT capability

Common Standards

EN IEC 61000-4-4, EN IEC 61000-4-5, EN 61000-4-12,

ANSI C62.41, C62.45, UL 1449

EFT Burst 5/50ns:

 

  Standards

IEC 61000-4-4, ed.3

  Voltage Waveform into 50Ω load

5ns Rise Time±30%, 50ns pulse width ±30%,

  Voltage Waveform into 1000Ω load

5ns Rise Time±30%, 50ns pulse width ±30%,

  Voltage Amplitude

±100V – 2.4kV into 50Ω, ± 200V – 4.8kV into 1000Ω

  Burst Duration

1µ to 1999 s

  Burst Period

1 ms to 4200 s

  Frequency

100Hz to 1000kHz

Combination Wave Surge:

 

  Standards

IEC 61000-4-5 ed. 3, EN 61000-4-5, ANSI C62.41.2 Cat A& B, UL 1449 ed. 3 sec. 37, ANSI C62.45

  Open Circuit Voltage Waveform

1.2µs Front Time ±30%, 50µs Duration ±20%

  Short Circuit Current Waveform

8µ Front Time ±20%, 20µs Duration ±20%

  Peak Open Circuit Voltage

200V–6.6kV

  Peak Short Circuit Current

100A–3.3kA @2 Ω, 16.6-550A@12Ω

100kHz Ringwave:

 

  Standards

IEC 61000-4-12, EN 61000-4-12, ANSI C62.41.2 Cat A& B,   ANSI C62.45

  Open Circuit Voltage Waveform

100kHz Damped Cosine, risetime=.5µs+/-30%,

Damping= 40%/peak

  Peak Open Circuit Voltage

200V–6.6kV @12 Ω or @ 30 Ω

  Peak Short Circuit Current

±6.6 to ±220 A ±10%@30 Ω

±16.6 to ±550 A ±10%@12 Ω

  Impulse Repetition Rate

10s from 200V to 4400V, 20s from 4401V to 6600V

Dips and Interrupts:

INA 6502 external variac is available as a separate option

 

Common Standards

EN IEC 61000-4-4, EN IEC 61000-4-5, EN 61000-4-12,

ANSI C62.41, C62.45, UL 1449

External Three Phase CDN 3063:

Other optional CDN’s (CDN 3063, 3083) are available also

  AC Voltage             

30-480 VAC, single or 3 phase

  AC Current

32 A  continuous, Max 50A for 10 min.

  DC Voltage

0-125 VDC, 225 VDC if current <7A

  DC Current

32 A  continuous, Max 50A for 10 min

  Control

Automatic through the NSG3060

  Connection to generator

Fischer S105 A 004/10.7

  Weight

42 kilograms, 100 pounds

  Dimensions

45x31x56 cm, 18x12x22 inches

Dips and Interrupts:

INA 6502 external variac is available as a separate option

 

I would recommend Transient Specialists. Transient Specialists always provides quality products within the established timeframes. The equipment always meets the specifications and properly shipped within the time frames within the time frames promised. 

Scott D., TUV SUD Canada

Transient Specialists has been outstanding at working with us for our specialized EMC equipment rental needs. Fast shipments and excellent accommodation for some customized setups. I recommend them highly and they are a pleasure to partner with!

John H., Gates Air, Inc.

Laura, I want to thank you and Goran for your excellent customer service and turn around time on the rentals and the calibration documents.  

Adam P., Clark Testing

Working for a testing company I deal with renting equipment all the time.  Transient Specialist is the first company I call on my list of rental houses because of their great personnel, prompt delivery of the equipment, knowledgeable and accommodating to the customers needs.

Richard T., National Technical Systems