IEC 61000-4-18 DOW Test System - Fast & Slow Wave Rental
Overview
This system all by EMC Partner consists of the MIG-OS-OS1 and DOW3000 pulse generators with the CDNs for damped oscillatory waves testing to all 5 associated frequencies of IEC 610000-4-18. An ISO 17025 accredited calibration comes standard with the rental. This products easy to use software allows for quick and easy testing and changing of parameters. This test solution is ideal for testing to a variety of damped oscillatory testing including ANSI C37.90, IEC 61000-4-18, IEC 60255-22-1, and many others.
Specifications
Common Standards |
EN/IEC 61000-4-18 |
External CDN: |
Single or 3 phase coupler/decoupler with 4 I/O line paths |
AC Voltage and Current |
Up to 480VAC, 25A max AC |
DC Voltage and Current |
115 VDC max. L to L, 60V L to N, 25A max. |
1 MHz, 100kHz IEC Damped Oscillatory: |
|
Standard: |
IEC 61000-4-18, IEC 60255-22-1 |
Voltage Peak open circuit |
250V – 10% to 3kV + 10% |
Voltage Risetime |
75ns Rise Time ±20% |
Oscillation Frequencies |
1MHz ± 10%, 100kHz ± 10% |
Output Impedance |
200 Ω ± 20% |
Decay |
50% of peak value between 3rd and 6th period |
Burst Duration |
1 up to 99 s ± 10% |
Repetition rate maximum |
400/s for 1MHz, 40/s for 100kHz |
1 MHz ANSI / IEEE Damped Oscillatory: |
|
Standard: |
ANSI / IEEE C37.90.1 |
Voltage Peak open circuit |
250V – 10% to 3kV + 10% |
Voltage Risetime |
50 – 100 ns Rise Time |
Oscillation Frequencies |
1MHz – 1.5MHz |
Output Impedance |
150 Ω ± 20% |
Decay |
50% of peak value after 6 µs |
Burst Duration |
1 up to 99 s ± 10% |
Repetition rate maximum |
400/s for 1MHz, 40/s for 100kHz |
Weight – MIG-S-OS1 |
28kg, 62 pounds |
Weight – CDN 2000-6-25 |
26kg, 57 pounds |
Dimensions – MIG-OS-OS1 |
45x57x38cm, 17x22x15 inches |
Dimensions - CDN 2000-6-25 |
45x50x19cm, 17x20x7.5 inches |
3 MHz, 10 MHz, 30 MHz IEC Damped Oscillatory: |
|
Standard: |
IEC 61000-4-18 |
Voltage OC direct out |
0.4 kV – 4.4 kV |
Voltage OC CDN out |
0.4 kV – 4.0 kV |
Voltage calibrated |
0.5 kV – 4 kV ± 10 % |
Voltage waveform decay |
Pk5 > ½ · Pk1, Pk10 < ½ · Pk1 |
Output impedance |
50 Ω |
Repetition rate maximum |
400/s for 1MHz, 40/s for 100kHz |
Voltage rise time |
5 ns ± 30 % |
Pulse repetition |
max. 6666 / s |
Burst duration |
1 ms – 20 s |
Current waveform decay |
Pk5 > ¼ · Pk1, Pk10 < ¼ · Pk1 |
Burst repetition |
10 ms – 200 s |
Current SC direct & CDN |
8 A – 88 A @ all frequencies |
Current SC calibrated |
10 A – 80 A ± 20 % |
Current rise time |
< 330 ns @ 3 MHz < 100 ns @ 10 MHz < 33 ns @ 30 MHz |
Polarity |
positive, negative, alternating |
Synchronization |
0 – 359° ± 10°, 1° step |
Ramp |
test voltage |
Optional accessories |
CN-EFT1000, VERI01 OSI, VERI1K EFT, VERI50-EFT |
Standards
Widely Used Standards
This list is a more comprehensive list of all the standards covered with this automotive load dump generator. This is by no means all the standards covered, but the major ones from the largest manufacturers and most widely used standards.
- IEC 60255-4
- IEC 6055-22-1
- IEC 61000-4-18
- IEC 60834-1
- VDE 435 Teil 303