ThermoScientific EMCPro Plus - Front Side
ThermoScientific EMCPro Plus - Front
ThermoScientific EMCPro Plus- - Back
ThermoScientific EMCPro Plus Front Top
ThermoScientific EMCPro Plus - Front Side Above

ThermoScientific EMCPro Plus

Rent 6 kV Transient Test System
  • 6 kV Surge, 4.4 kV EFT, & 6 kV 100 kHz Ringwave
  • Built-in CDN Max 250 V/16 A AC or 100 V/10 A DC
  • Capabilities for Voltage Dips Testing
  • Operated via Front Panel Display
  • Current ISO 17025 Accredited Calibration

Included Accessories

  • Conducted Immunity System
  • EUT Power Cord In
  • EFT Grounding Bracket
  • 10A250V plug
  • (4) Safety Plugs
  • Interlock Plug
  • Square EUT Connector
  • EMC-Pro Software
  • FC-11 Fibercom Converter
  • 10m. Fibercom Cable
  • RS232 C-11 Cable
  • Printed Manual
  • Serial to USB
  • Software
  • Calibration Documentation
  • Shipping Case 
Can't find something? Contact Us
Got Questions? Speak to an Expert +1 630-887-0329
Two FREE days transit with every rental

Description

The EMCPro PLUS is an advanced EMC immunity test system developed by Thermo in response to manufacturers’ demands for a mid-range, low cost, multi-capability test system. The EMCPro PLUS is easily configured to meet today’s immunity standards required for CE Marking and compliance requirements. In addition, EMCPro PLUS capabilities go well beyond the required test levels for the CE Mark

The EMCPro PLUS performs compliance level testing requirements for IEC, UL, ANSI, ETSI and beyond.

Users may operate the EMCPro PLUS via Thermo’s easy to use Windows-based PC software, CEWare, or from the front panel. CEWare provides simple, straightforward pre-programmed test sequences ideal for the novice user; yet is sophisticated enough to allow an advanced user to develop and save custom test sequences for future testing.

Users may configure the EMCPro PLUS from a single test capability to up to seven capabilities in a single unit. When test requirements change, or as standards evolve, upgrading is a simple matter of adding appropriate options or accessories offered by Thermo to their current EMCPro PLUS.

One System, One Vendor, One Solution.

The EMCPro PLUS system offers the highest test levels and the widest selection of testing capabilities in a low-cost complete system solution.

Specifications:
Model: PRO-Base
System Operating Voltage:
90-240VAC, 50/60Hz
Integrated EUT Mains (CDN):
AC Voltage: 1 phase, 50 - 250 VAC
Frequency: 50/60 Hz
DC Voltage: 100 VDC, Max
Current: 16 A, Max AC @250VAC, 10A, Max DC to 100VDC, 16A, Max to 48VDC
EUT Connectors:
NEMA, British, Schuko, India, Australia, China
Control Interface:
Manual Via Front Panel VDU
Computer Via RS232/USB Fiber-optic interface
Safety Features:
External Interlock for users, Interlock for CCL connector, External stop input
Environmental Operating Conditions:
Temperature +15 C to +40 C
Humidity 10 - 75%, non-condensing Altitude
8000 ft. maximum
Physical Specifications:
Height: 22.9 cm (8.7 in)
Width:43.4 cm (17.1 in)
Depth: 64.8cm(25.5in)
Weight: 39 kg (85 lb)
CE Marking:
Safety (LVD) and EMC Directives
Surge Waveform Monitoring:
Monitors are switched automatically to match generator coupling mode.
Voltage monitor provides 1000:1 +/-10% attenuation factor
Current monitor provides 200:1 +/-10% attenuation factor
Model: PRO-EFT
EFT Testing
IEC 61000-4-4, Ed.3; EN 61000-4-4; ANSI C62.41.2; ANSI C62.45
Voltage Waveform (into 50? load):
5 ns RT +/-1.5ns; 50ns PW +/-15ns; Burst Duration 15ms +/-3ms @5kHz, 0.75ms +/-0.15ms @100kHz; Burst Period 300ms +/-60ms; Vpk 125V-2kV
Voltage Waveform (into 1000? load):
5 ns RT +/-1.5ns; 50ns PW -15, +100ns; Burst Duration 15ms �3ms @5kHz; 0.75ms +/-0.15ms @100kHz; Burst Period 300ms +/-60ms; Vpk 240V-4kV
Frequency:
1-100 kHz, in 0.5k Hz steps, +-/10%
Model: PRO-Surge
Surge
per IEC 61000-4-5, Ed. 3, EN 61000-4-5, ANSI C62.41.2 Cat A & B, UL 1449 Ed. 3 Sect. 37; ANSI C62.45
Direct Output
OC Voltage Waveform:
1.2us Front Time +/- 30%
Duration 50us +/-20%
SC Current Waveform:
8us Front Time +/-20%
Duration 20us +/-20%
Peak OC Voltage:
250V - 6.0kV +/-10%, 2 Ohm or 12 Ohm mode
Peak SC Current :
125 A - 3.0kA +/- 10% 2 Ohm mode
20.8 - 500A +/- 10% 12 Ohm mode
Impulse Repetition Rate:
Up to 2 impulses/min @6kV
Voltage Undershoot:
30% Max
Coupling Capacitor:
18�F (Internal to generator)
Output of CDN
OC Voltage Waveform:
1.2us Front Time +/-30%
Duration 50us +/-10us
Peak OC Voltage:
Set voltage +/- 10% either mode (2 Ohm or 12 Ohm)
Voltage Undershoot:
N/A at CDN
Residual Surge Voltage:
less than or equal to 15% of Set Voltage or less than or equal to 480V, whichever is higher
Model: PRO-Ring
Ring Wave Surge
per ANSI C62.41.2, Cat A, B; IEC 61000-4-12 and EN 61000-4-12; ANSI C62.45
OC Voltage Waveform:
100kHz Damped Cosine RT = 0.5us +/-30% Damping = 40%/peak
Peak OC Voltage:
250V - 6.0kV +/-10%, 12 Ohm or 30 Ohm mode
Peak SC Current2 :
200A +/-10% 30Ohm mode
500A +/-10% 12 Ohm mode
Impulse Repetition Rate:
Up to 2 impulses/min @6kV (~24 Sec Charge Time)
Video Guides
KeyTek EMC Pro Plus Test System Overview