Description
Surge/Combination Wave ECAT Module Features
- Surge/Combination Wave Voltage up to 10 kV
- ISO 17025 Calibration Included
- IEC/EN 61000-4-5 & ANSI C62.41 Compliant
- Can Be Rented w/without E103 System
- Free Technical Support & 2 Days Free Transit
- Must be Used with ECAT E103 Controller
Overview
Thermo Keytek, E 510 Bi-wave Surge module to 10kV per IEC 61000-4-5 for the ECAT system, requires the E103 controller. This module can be rented individually or with an ECAT System including the E103. This product, does not come with E103 or CDN, which can also be rented for a complete system. This system comes standard with an ISO 17025 accredited calibration and technical support.
Data SheetUser ManualSpecifications
E510B - Combination Wave Surge for ECATS |
|
Standards |
IEC 61000-4-5 ed. 3, EN 61000-4-5, ANSI/IEEE C62.41.2 Cat. B, UL 1449 |
Open Circuit Voltage Waveform |
1.2µs, Front Time ± 30%, 50µs Duration ±30% |
Short Circuit Current Waveform |
8µs Front Time ±20%, 20µs Duration ±20% |
Peak Open Circuit Voltage |
200V–10kV, ±10% |
Peak Short Circuit Current |
100A–5kA, ±10%@2Ω, 20.8-550A ±10%@12Ω |
Pulse Repetition Rate |
1 shot/18 seconds |
Weight |
16 kg, 55 pounds |
Dimensions |
42x52x21cm, 16x20 x8 inches |