Video Guides Teseq NSG 4070
BCI/Current Injection Clamp Method
The Teseq NSG 4070 is an ideal conducted RF Test system for bulk current injection or current clamp method according to a variety of commercial, military, and automotive requirements. The test setup includes a variety of components including bulk current injection probe, monitoring probe(s), attenuators, cabling, and external amplifiers if necessary.
Teseq System Overview
This video made by Teseq, provides an overview of this conducted RF immunity test system. It provides an overview of the system itself, accessories, including coupling clamps, controls, interface, and manipulating testing parameters. It also mentions briefly about compliance to IEC 61000-4-6 and other testing standards.
Data SheetTeseq - Software Download
Overview
The NSG4070 by Teseq is a multifunctional device for carrying out EMC testing for conducted and radiated immunity testing to a variety of standards. Take advantage of ISO 17025 calibrations, a variety of accessories, a quick delivery on this compact equipment.This Conducted RF Immunity Test Generator modular set-up using internal (80 Watts) or external amplifiers enables a large variety of applications.
The powerful and easy to use firmware from an external PC and control software, however it can also be remote controlled for system operation. A state-of-the-art data transfer of test and measurement data for documentation is provided by USB stick to be plugged into the front pane.
The NSG 4070 was designed to testing in accordance to EN/IEC 61000-4-6, EN/IEC 60601-1-2, EN/IEC 61000-4-20, EN/IEC 61000-4-21 and several automotive standards. This immunity test product provides various sweep methods which can be selected to suit each particular testing parameter. This Teseq conducted RF test equipment also allows for all coupling methods to be simply and easily connected and calibrated.
Specifications & Overview
Common Standards |
EN/IEC 61000-4-6, EN/IEC 60601-1-2, ISO 11452-4, EN/IEC 62132 |
Generator |
|
Frequency Range |
9 kHz to 1 GHz |
Resolution |
1 Hz |
RF Level Range |
-60 dBm to +10 dBm |
RF Level Resolution |
.1 dBm |
Amplitude Modulation Frequency
1 Hz to 50 kHz |
|
Amplitude Modulation Resolution |
1 Hz |
Pulse Modulation Rise/Fall Time |
<1µs (10% to 90%) |
Pulse Modulation Frequency Range |
1 Hz to 50 kHz |
Pulse Modulation Freq. Resolution |
1 Hz |
Pulse Modulation Duty Cycle |
10% to 90% |
Power Meter |
|
Frequency Range |
9 kHz to 1 GHz |
Line Measurement Range |
Channel 1 -35 dBm to +27 dBm, Ch 2&3 -45 dBm to 20dBm |
Maximum Input |
+28 dBm |
Noise Level |
>5 dB below the measurement range |
Input Return Loss |
>20 dB (below 500MHz), >17 dB (500MHz to 1 Ghz) |
Connector |
BNC socket, 50Ω |
Power Amplifier |
|
Output Power |
Max 80W |
Frequency Range |
150 kHz to 230 MHz |
Input Impedance |
50 ohm |
Output Impedance |
50 ohm |
Direct RF Output |
To control an external amplifier |
Input Return Loss |
Min. 10 dB |
Output Return Loss |
Nominal Min. 9.5 dB, 0 dB without damage |
Gain |
Min 50 dBm |
Linear Output Power |
Min 48 dBm |
Max. Input Power without Damage |
Max. +10 dBm |
Harmonic Distortion |
Typ. <-20 dBc |
Weight |
15 kg, 33 pounds |
Dimensions |
45x43x15 cm, 17x16x6 inches |