Description
Overview
The NSG 3150 by Teseq is an EMC immunity test generator for Combination Wave Surges to 15kV, and offers solutions for both CE mark, IEC, and ANSI testing. This product includes the CDN 3153, which allows for three phase coupling/decoupling up to 63 amps, 690 volts AC, and 125 volts DC. This test equipment comes with an ISO 17025 accredited calibration and all necessary cords included in the rental price. The NSG 3150 and CDN3153 system is compliant with the latest version of EN/IEC 61000-4-5.
This Surge Immunity Test Generator comes with the standard an easy to use Teseq interface that includes a 7" color screen and thumb wheel for adjustments. This test sytem offers flexible repetition time setting for significant reduction in test times. The 15kV surge generator also provides quick launch testing from an extensive Standards Library or User Test folders.
This compact EMC surge immunity test set is the perfect solution for outdoor applications. The NSG3150 15kV capabilities surpasses many testing requirements and can be controlled via laptop or through color display. This combination wave generator is ideal for testing to EN/IEC 61000-4-5, ANSI C62.41, C62.45, and UL 1449.
Data SheetUser ManualSpecifications
Common Standards |
EN/IEC 61000-4-5, ANSI C62.41, C62.45, UL 1449 |
External Three Phase CDN 3153-S63: |
|
AC Voltage |
up to 690V |
AC Current |
up to 63A |
DC Voltage |
up to 1000 VDC |
DC Current |
up to 63A |
Combination Wave Surge: |
|
Standards |
IEC 61000-4-5 ed. 3, EN 61000-4-5, ANSI C62.41.2 Cat A& B, UL 1449 ed. 3 sec. 37, ANSI C62.45 |
Open Circuit Voltage Waveform |
1.2µs Front Time ±30%, 50µs Duration ±20% |
Short Circuit Current Waveform |
8µ Front Time ±20%, 20µs Duration ±20% |
Peak Open Circuit Voltage |
200V–15kV |
Peak Short Circuit Current |
100A–3.3kA @2 Ω, 16.6-550A@12Ω |
Pulse voltage (open circuit): |
±500 V to 15 kV (in 1 V steps) |
Pulse current (short circuit): |
±250 A to 7.5 kA |
Impedance: |
2/12 Ω |
Polarity: |
positive/negative/alternate |
Pulse repetition: |
20* .... 600 s (in 1 sec steps) 1 .... 10 min |
Test duration |
1 to 9999 pulses, continuous |
Phase synchronization |
asynchronous, synchronous 0 to 359º (in 1º steps) |
Coupling |
IEC/external |
Weight |
44 kilograms, 93 pounds |
Dimensions |
45x56x56 cm, 18x22x22 inches |
Standards
Widely Used Standards
This list is a more comprehensive list of all the standards covered with this conducted immunity generator. For compliance testing to any standards not covered under the list below, please contact us prior to rental.
- EMC Directives
- UN ECE R10 (Automotive)
- IEC/EN 61000-4-5
- IEC/EN 61000-4-9
- EN 61000-6-1
- EN 61000-6-2