Teseq KEMZ 801A
Rent 1 GHz 100 Watt EM Clamp
Features
- Frequency Range 10 kHz to 1 GHz
- Includes CAL 801A Calibration Adapters
- 50 Ohm Termination Load Provided
- 10 kHz - 230 MHz 100 Watts Maximum
- 20 mm Maximum Cable Diameter
- KEMZ 801A Serial s/n
- CAL 801A Serial (2 Pieces)
- LE 211A golden bar
- 50 Ohm Termination (N)
- Printed Manual
- N to BNC Adapters 3pcs
- Black Pelican Case
Description
IEC 61000-4-6 (EN 61000-4-6) defines three basic types of transducers used for the injection of test signals into the equipment under test (EUT). The basic requirement is to inject a known level of RF signal into the cable of the EUT at each test frequency and to determine a possible susceptibility of the EUT. The EM clamp injects the disturbance signal by a combination of inductive and capacitive coupling.
The normative Annex A of IEC/EN 61000-4-6 specifies the EM clamp and provides additional information regarding the clamp characterization. The KEMZ 801A complies to the standard. The adapter kit CAL 801A, which allows test level setting and correction factor measurement, is offered optionally. The calibration fixture CAL KEMZ is made for the S-parameter measurements as defined in Annex A of IEC/EN 61000-4-6 edition 4.
- Technical Specifications:
- Frequency range:
- 10 kHz to 1000 MHz
- Nominal impedance:
- 50 Ohms
- Connector:
- N-type female
- Maximum input level
- 0.01 to 100 MHz:
- 100 W for 15 min
- 100 to 230 MHz:
- 100 W for 3 min
- 230 to 1000 MHz:
- 50 W for 3 min
- Correction factor 0.15 to 300 MHz:
- >= -4 dB/<= 5 dB (see graph)
- Clamp opening diameter:
- approx. 21 mm
- Maximum cable diameter:
- 20 mm
- Dimension (LxWxH):
- 647 mm x 130 mm x 105 mm
- Height of ferrite center above ground:
- 50 mm
- Distance to the reference point (first ferrite):
- approx. 22 mm
- Weight:
- approx. 7 kg