Ask Us About: EN/IEC 61000-4-11 - Dips & Interruptions Immunity
Transient Specialists
Filters
Recent Views
EN/IEC 61000-4-11 - Dips & Interruptions Immunity
Showing 1 - 12 of 12 products
Display
View
EM Test NetWave 7.3 - Rent 7.5 kVA Programmable Power Supply
- Programmable Multifunctional AC/DC Source
- Max Single Phase 360 Volts AC 500 Volts DC
- Model NetWave 7.3 - Includes Built-in Transformer
ThermoScientific EMCPro Plus - Rent 6 kV Transient Test System
- 6 kV Surge, 4.4 kV EFT, & 6 kV 100 kHz Ringwave
- Built-in CDN Max 250 V/16 A AC or 100 V/10 A DC
- Capabilities for Voltage Dips Testing
EM Test NX7 bsprt-1-400-32 - Rent Telecom Transient Generator
- 7 kV Surge, Ringwave, Telecom Surge, & 5.5 kV EFT
- Built-in single phase CDN Max 400 V/32 A AC or DC
- 400 Volt Model: bsprt-1-400-32
EM Test Variac NX 1-260-16 - Rent Single Phase Motor Variac
- Single Phase Motor Variac
- Capabilities for Voltage Dips & Variations
- Maximum 260 Volts 16 Amps AC
EM Test V4780 S2 - Rent Single Phase Tapped Transformer
- Single Phase Tapped Transformer
- Maximum 250 Volts 16 Amps
- Designed for EM Test NX & UCS 500 series
EMC Partner IMU4000 - Rent 4kV EFT, Surge, & Dips System
- 4 kV Surge & 4.4 kV EFT/Burst Capabilities
- CDN Max 280 V/16 A AC or 300 V/16 A DC
- Capabilities for Voltage Dips up to 6 Amps
Teseq INA 6502 - Rent Automatic Dips Transformer
- Single Phase Automatic Step Transformer
- Maximum 250 Volts 16 Amps
- Designed for Teseq NSG 3060 & NSG 3040
California Instruments EOS1 - Rent IEC 61000-4-11 Electronic Switch
- Compliant for IEC 61000-4-11 Testing
- Used with California Instruments iX Supplies
- Designed for Voltage Dips & Interruptions
Haefely DIP 116 - Rent Automatic Dips Transformer
- Single Phase Dips Transformer
- Maximum 264 Volts 16 Amps
- Designed for Haefely AXOS Series
Thermo Keytek ECAT EP62 - Rent & Buy IEC 61000-4-11 Module
- Maximum 240 Volt & 32 Amps
- Designed for IEC 61000-4-11 Testing
- Must be used with E103 Control Unit
Sale price
$8,000
Teseq ProfLine 2105 - 5 kVA Harmonics & Flicker Test System
- Designed for Flicker & Harmonics Testing
- Complete Test System for IEC 61000-3-2 and 3-3
- Max Single Phase EUT 300 Volts 16 Amps
- Compliant for 3-Phase AC Voltage Dips & Interruptions
- Max 480V L-L Test Voltage (WYE)
- Designed for use with AFX & LMX Sources
12 products
Description
IEC 61000-4-11:2004 Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations
Overview
EN IEC 61000-4-11 sets the immunity test methods and range for equipment connected to low-voltage power supply networks for voltage dips, short interruptions, and voltage variations. It covers equipment not above 16A/phase for connection to 50 or 60 Hz A.C. Part 4-11 falls into the greater structure of EN IEC 61000 which covers broader EMC concepts. Voltage dips and short interruptions are caused by faults in the network, primarily short circuits, in installations or by sudden large changes of load. In certain cases, two or more consecutive dips or interruptions may occur. Voltage variations are caused by continuously varying loads connected to the network against a certain benchmark. This standard can be purchased at the IEC Webstore.
Testing
This immunity standard categorizes three levels of testing and can be verified by Dips and Interrupts EMC Test Equipment. The three different classes are defined further in the standard allowing testing to be conducted accordingly. This standard does not define testing with pass/fail criteria but on performance criterion, similar to that of other IEC standards.This standard does not cover equipment for connection to 400 Hz A.C. It places regulation on the environment, limits, testing and measurement techniques, installation and mitigation guidelines, and many other criteria.
Equipment
Section 11 sets the requirements for EMC test equipment to test for voltage dips, short interruptions, and voltage variations. It specifies preventing the emissions of heavy disturbances on power supply and providing voltage dip equal or more severe then required by the standard. We offer rental products by Teseq, EMC Partner, EM Test, and Thermo-Keytek. We also provide a variety of rental accessories for our equipment allowing customers to meet a variety of requirements. The most commonly rented equipment to simulator this event are the Profline, NSG 3060, UCS500n7, TRA3000, and EMC Pro. These EMI dips and interrupts products come with an A2LA accredited calibration and free technical support included with the rental.
Filters (0)
Transient Specialists
Filters