Conducted Immunity Test Equipment Rentals
- 16.5 kV Air & 9 kV Contact Discharge (100 V Steps)
- Rechargeable Battery Powered ESD Simulator
- Built-in 150 pF/ 330 Ohm Network
- 5 kV Surge & EFT Immunity Test System
- Built-in CDN Max 264 V/16 A AC or 220 V/10 A DC
- Capabilities for Voltage Dips Testing with DIP 116
- Configuration: 5 kV Surge, 5.5 kV Burst, & Power Fail
- Built-in single phase CDN Max 300 V/16 A AC or DC
- Laptop with iec.control software included
- Built-in 80 Watts 150 kHz to 230 MHz Amplifier
- 1 GHz Signal Generator & 3 Power Meter Inputs
- Preprogrammed Test Routines/Sequences
- 16 kV Air Discharge & 10 kV Contact-discharge (100 V Steps)
- Rechargeable Battery Powered ESD Simulator
- Includes DM1 150pF / 330Ω Network for IEC 61000-4-2 Testing
- 6.6 kV Surge, 4.8 kV EFT, & 6.6 kV 100 kHz Ringwave
- External Single Phase CDN Max 270 V/16 A AC or DC
- Laptop with WIN 3000 Software Included
- 7 kV Surge, 5.5 kV EFT, & 7 kV 100 kHz Ringwave
- Built-in CDN Max 264 V/16 A AC or 220 V/10 A DC
- Compliant to ANSI Coupling Requirements
- 4 kV Surge & 4.4 kV EFT/Burst Capabilities
- CDN Max 280 V/16 A AC or 300 V/16 A DC
- Capabilities for Voltage Dips up to 6 Amps
Need help selecting the right immunity equipment?
ESD Simulators - Rent & Buy Systems
Rent and buy ESD simulators from US distributor for Teseq and EM Test ESD simulators and test accessories in the United States. Get fast deliveries on ISO 17025 calibrated equipment, including test solutions for commercial, automotive, and military applications.
- 16.5 kV Air & 9 kV Contact Discharge (100 V Steps)
- Rechargeable Battery Powered ESD Simulator
- Built-in 150 pF/ 330 Ohm Network
- 16 kV Air Discharge & 10 kV Contact-discharge (100 V Steps)
- Rechargeable Battery Powered ESD Simulator
- Includes DM1 150pF / 330Ω Network for IEC 61000-4-2 Testing
- 30 kV Air & Contact Discharge (100V Steps)
- Rechargeable Battery Powered ESD Simulator
- Charge Removal Feature Capabilities
- 16 kV Air Discharge & Contact Discharge (100 V Steps)
- Simple Easy to Navigate Touch Screen
- Predefined Test Routines According to Standards
- 30 kV Air & Contact Discharge (100V Steps)
- Rechargeable Battery Powered ESD Simulator
- Includes 150 pF/ 330 Ohm Network (INA 4380)
- 16 kV Air & 10 kV Contact Discharge (10 V Steps)
- Light Weight Ergonomic Design
- 150 pF/ 330 Ohm Network Installed
- 30V Air & Contact Discharge (100V Steps)
- Color Touch Panel Control with Activity Log
- Includes 150 pF/ 330 Ohm Network (INA 4380)
- 15 kV Air Discharge & 8 kV Contact Discharge (10V Steps)
- Rugged, Portable, and Self Contained ESD Simulator
- Meets Requirements of IEC 61000-4-2 & ANSI C63.16
Coupling Decoupling Networks
Rent both power and data line CDNs designed for meeting a variety of EUT/DUT immunity testing requirements. We offer both manual and automatic power mains CDNs up to 125 Amps meeting the newest requirements of IEC 61000-4-5.
- Coupler for Surge, EFT, & Ringwave Pulses
- Max 125 Amps 690 V AC or 1,000 V DC
- Transient Generator Mounted in Rack
- Coupler for Surge to IEC 61000-4-5
- Max 100 Amps 690 V AC or 620 V DC
- Manual Coupler for NSG 3060 or NSG 3040
- Designed for Burst to IEC 61000-4-4
- Max 100 Amps 690 V AC or 1,000 V DC
- Handles up to 8.8 kV EFT/Burst Pulses
- Coupler for Surge, EFT, & Ringwave Pulses
- Max 480 Volts 32 Amps AC
- Automatic Coupler for NX5/NX7 Systems
- Coupler for Surge, EFT, & Ringwave Pulses
- Maximum 480 Volts 32 Amps AC/DC
- Automatic Coupler for Axos5/8 Systems
- CDN for up to 8 wire unshielded twisted pair (UTP)
- Max Surge Voltage 2 kV Current 50 Amps
- Coupling to 1, 2 or 4 pairs
- Coupler for Damped Oscillatory Pulses
- Maximum 480 Volts 25 Amps AC
- Rented with MIG-OS-OS1 Generator
- Coupler for Surge, EFT, & Ringwave Pulses
- Maximum 270 Volts 16 Amps AC/DC
- Rented with Teseq NSG 3060 Test System
- Coupler for Surge, EFT, & Ringwave Pulses
- Maximum 480 Volts 32 Amps AC/DC
- Automatic Coupler for NSG 3060/NSG 3040
- CDN for Shielded & Unshielded Data Lines
- Maximum 3 kV Surge & 4 kV EFT/Burst
- Compatible to PoE and PoE+ requirements
- Construction as per IEC 61000-4-4 Ed.3
- EFT/Burst Testing of Signal- and Datalines
- Permissible Burst Voltage 7 kV
- Construction as per IEC 61000-4-4 Ed.3
- EFT/Burst testing of signal and data lines
- For cable diameter from 4 – 40 mm
- IEC 61000-4-4 & IEC 61000-4-18 Compliant
- Designed for Coupling to I/O Lines
- Useable for Damped Oscillatory Wave Testing
- Coupler for Surge to IEC 61000-4-5
- Max 100 Amps 690 V AC or 1,000 V DC
- Manual Coupler for NX5/NX7 Systems
- Coupler for EFT/Burst to IEC 61000-4-4
- Max 100 Amps 690 V AC or 1,000 V DC
- Manual Coupler for NX5/NX7 Systems