Ask Us About: CEMark

Filters

CEMark

Showing 1 - 16 of 44 products
View
CI EOS 1 - FrontCI EOS 1 - Side
California Instruments EOS1 - Rent Electronic Switch
  • Compliant Switch for IEC 61000-4-11 Testing
  • Used with California Instruments iX Supplies
  • Designed for Voltage Dips & Short Interruptions 
Request A Quote
EM Test Coupling NX7 bsr-3-690-125.3 & NX Transient Generator - Front SideEM Test Coupling NX7 bsr-3-690-125.3 & NX Transient Generator - Front
Coupling NX7 bsr-3-690-125.3 - 125Amp 3-Phase Surge & EFT CDN
  • Automatic 690V/125A 3-Phase Surge & EFT Coupler
  • Compliant Current Ratings <32, 63, 125Amps
  • Must be Used with 400Volt NX5/NX7 Models
ISO 17025 Calibrated
Request A Quote
EM Test Coupling NX7 bsr-3-690-63 - Front EM Test Coupling NX7 bsr-3-690-63 - Front Side
Coupling NX7 bsr-3-690-63 - Rent 63Amp 3-Phase Surge & EFT CDN
  • Automatic 690V/125A 3-Phase Surge & EFT Coupler
  • Compliant Current Ratings <32, 63, 125Amps
  • Must be Used with 400Volt NX5/NX7 Models
Request A Quote
EMC Partners ESD Network for the ESD 3000 150pf/330OhmESD 3000 EMC Partner ESD Simulator Components
DM1 150pf/330‎Ω Network Rent & Buy - IEC 61000-4-2
  • EMC Partner 150pF/330Ohm Module
  • Compliant for IEC 61000-4-2 & ANSI C63.16
  • Requires the ESD 3000 Unit for Use
Request A Quote Choose options
EM Test CNI 503B7 - Rent 32Amp 3-Phase Surge & EFT CDN
EM Test CNI 503B7 - Rent 32Amp 3-Phase Surge & EFT CDN
  • 3-Phase EFT & Surge CDN 480 Volts 32 Amps
  • Used with EM Test UCS 500N Series of Generators
  • Compliant to IEC 61000-4-5/4 Coupling Methods
Request A Quote
EM Test NX7 - System & Laptop Side FrontEM Test NX7 - Front
EM Test Compact NX7 - Rent 7 kV Transient Generator
  • 7kV Surge & Ringwave, 5.5kV EFT/Burst Test System
  • Built-in CDN 300V/16Amps & External Rental Couplers
  • Variety of CDNs & Clamps - Compatible & Compliant 
ISO 17025 Calibrated
Request A Quote
EM Test Coupling NX7 bsr-3-480-32 - Rent 3-Phase 32Amp CDNEM Test Coupling NX7 bsr-3-480-32 - Rent 3-Phase 32Amp CDN
EM Test Coupling NX7 bsr-3-480-32 - Rent 3-Phase 32Amp CDN
  • EFT & Surge Coupling Decoupling Network
  • Maximum 480 Volts 32 Amps AC 
  • Used with EM Test NX5/NX7 Generators
ISO 17025 Calibrated
Request A Quote
EM Test NX5 - Test System Laptop SoftwareEM Test NX5 - Front
EM Test NX5 bsp-1-300-16 - Rent 5 kV Surge & EFT Generator
  • 5 kV Surge, 5.5 kV Burst, & Power Fail
  • Built-in CDN Max 300 V/16 A AC or DC
  • External Power & Dataline CDN Rentals
Price Match Guarantee
Request A Quote
EM Test NX5 bsp-1-300-32 - Front Side with LaptopEM Test NX5 bsp-1-300-32 - Front Top
EM Test NX5 bsp-1-300-32 - Rent Transient System 32Amp CDN
  • 5 kV Surge, 5.5 kV Burst, & Power Fail
  • Built-in CDN Max 300 V/32 A AC or DC
  • Power & Dataline CDN Available 
Price Match Guarantee
Request A Quote
EM Test NX5 bsp-1-400-16 - Front Side with LaptopEM Test NX5 bsp-1-400-16 - Front Side
EM Test NX5 bsp-1-400-16 - Rent Transient Generator 400V CDN
  • 5kV Surge & 5.5kV EFT Transient Pulse System
  • CDN 400v/16amp AC/DC Model 
  • Ideal for higher voltage DC DUT
Price Match Guarantee
Request A Quote
EM Test NX7 Telecom - Front Side Laptop SoftwareEM Test NX7 Telecom - Front
EM Test NX7 bsprt-1-400-32 - Rent Telecom Transient Generator
  • 7kV Surge & Ringwave, 5.5kV EFT, Telecom10x700μs
  • Internal CDN Maximum 400 Volts / 32 Amps 
  • Variety of CDNs & Dips Transformer V4780 S2
ISO 17025 Calibrated
Request A Quote
EM Test PCD 8 B-3-690-1000-100 - Front SideEM Test PCD 8 B-3-690-1000-100 - Side
EM Test PCD 8 B-3-690-1000-100 - Rent 100Amp EFT/Burst CDN
  • EFT/Burst CDN Maximum 690 VAC 100Amps 
  • Compliant to IEC 61000-4-4 Requirements
  • Used with a Variety of EFT/Burst Test Systems
ISO 17025 Calibrated
Request A Quote
EM Test PCD 8 S-3-690-1000-100 - Front SideEM Test PCD 8 S-3-690-1000-100 - Side
EM Test PCD 8 S-3-690-1000-100 - Rent 100Amp Manual Surge CDN
  • Manual 690VAC/100Amp 3-Phase Surge CDN
  • Compliant to IEC 61000-4-5 Requirements
  • Used with NX or NSG 3000A series of Generators
ISO 17025 Calibrated
Request A Quote
EM Test UCS500N5 - Front SideEM Test UCS500N5 - Front
EM Test UCS 500N5E - 5.5kV EFT/Burst Pulse System
  • 5.5kV EFT/Burst Immunity Test System
  • Stand Alone System - Built-in 300V/16Amps CDN
  • Rent CCLs & Couplers for 3-Phase Power
Price Match Guarantee
Request A Quote
EMC Partner ESD3000 - Front SideEMC Partner ESD3000 - Side
EMC Partner ESD3000 - Rent 16 kV ESD Simulator/Gun
  • 16kV Air & 10kV Contact Discharge Test Levels
  • Compliant to IEC 61000-4-2 (150pF/330Ω)
  • Upgradable to 30kV & Many R/C Networks
Price Match Guarantee
Request A Quote Choose options
ESD 3000 DN1 EMC Partner - FrontESD 3000 EMC Partner EMC Immunity ESD Simulator - Components
EMC Partner ESD3000 DN1 - 30kV 150pF/330Ω Simulator
  • EMC Partner 30kV 150pF/330Ohm ESD System
  • Ideal for IEC 61000-4-2 & High Voltage ESD
  • Many Preprogrammed Test Routines 
Price Match Guarantee
Request A Quote

44 products