ISO 11452-4 - Harness Excitation BCI Method Rentals

Showing 1 to 9 of 15 products

BCI Test System 10kHz-230MHz

In Stock

Bulk Current Injection System 

      • Built in Class A Amplifier 80W 150kHz-230MHz
      • Laptop & ISO 17025 Calibration Included
      • Integrated signal generator 9 kHz - 1 GHz
      • Fischer Communications F-120-9A CIP & Accessories
      • Free Technical Support & 2 Days Free Transit
      • Turnkey Solution - Arrives Ready for Testing!

Overview

The NSG4070 by Teseq is a multifunctional device for carrying out EMC testing for conducted and radiated immunity testing to a variety of standards. Take advantage of ISO 17025 calibrations, a variety of accessories, a quick delivery on this compact equipment.This Conducted RF Immunity Test Generator modular set-up using internal (80 Watts) or external amplifiers enables a large variety of applications. 

Class A Broadband Amplifier

Teseq Broad Band Amplifier Features 

      • Class A Broadband Amplifier
      • 10kHz-400MHz 110 Watts Capabilities
      • Compact Design & Touch Screen Color display
      • Free Technical Support & 2 Days Free Transit
      • Easily Integrated  & Ideal for BCI testing
      • Mismatch tolerant and unconditionally stable
      • Turnkey Solution - Arrives Ready for Testing!

Overview

The Teseq CBA 400M-110 can supply 110Watt into a 50 ohm load over the range of 10kHz-400Mhz. This mismatch tolerant and unconditionally stable Class A broadband amplifier is ideal for bulk current injection (BCI) EMC Testing including automotive, military, and aerospace applications. This test equipment is powered by a switch mode power supply, is air cooled with integral fans, and protected against faulty cooling via temperature sensing.

This equipment provides testing to a wide variety of EMC immunity testing. It provides indicator lights for radio frequency (RF) interlock operations and over-temperature. The unique construction of this test equipment will continue to work at full power when presented with an open or short circuit at its output. This easy to use test system allows for easy testing to EN/IEC 61000-4-6, CISPR 24, and many other standards.

All of our power supplies come with all required cords for use and provide a turnkey testing solution. We also carry a variety of other amplifiers including the CBA 1G-300 (80Mhz-1Ghz 300W) and TI88-250 (7.5Ghz-18Ghz 250W) to facilitate higher frequency and power testing needs. This product requires mains plug only be connected in a socket providing protective earth contact.

CS114 BCI Probe & Cal Fixture

MIL-STD-461 Accessory Kit

      • Frequency 10kHz-400MHz
      • F120-6A BCI Probe included
      • Current Probe ISO 17025 Calibration
      • AE/EUT: Sub-D15 connectors
      • Comes with Current Probe, Fixture, & Adapter
      • Free Technical Support & 2 Days Free Transit

The F120-6A is a Fischer Custom Communications bulk current Injection Probe for testing products for immunity to conducted RF per Do 160 sec 114 & 20, Mil Std 461 CS114. Includes calibration fixture. The F-120-6A is a broadband, high effi ciency injection probe. Large RF currents can be coupled on to a signal or power circuit under test between 10 kHz – 400 MHz.

RF Test System 80W

In Stock

Conducted & Radiated RF Immunity Test Setup Features 

      • Conducted & Radiated Solution - IEC 61000-4-6/-3
      • Laptop & ISO 17025 Calibration Included
      • Integrated signal generator 9 kHz - 1 GHz
      • Integrated class A power Amplifier 35W, 45W, 80W
      • Free Technical Support & 2 Days Free Transit
      • 3 power meter inputs 9 kHz to 1 GHz
      • Turnkey Solution - Arrives Ready for Testing!

Overview

The NSG4070 by Teseq is a multifunctional device for carrying out EMC testing for conducted and radiated immunity testing to a variety of standards. Take advantage of ISO 17025 calibrations, a variety of accessories, a quick delivery on this compact equipment.This Conducted RF Immunity Test Generator modular set-up using internal (80 Watts) or external amplifiers enables a large variety of applications. 

The powerful and easy to use firmware from an external PC and control software, however it can also be remote controlled for system operation. A state-of-the-art data transfer of test and measurement data for documentation is provided by USB stick to be plugged into the front pane. 

The NSG 4070 was designed to testing in accordance to EN/IEC 61000-4-6, EN/IEC 60601-1-2, EN/IEC 61000-4-20, EN/IEC 61000-4-21 and several automotive standards. This immunity test product provides various sweep methods which can be selected to suit each particular testing parameter. This Teseq conducted RF test equipment also allows for all coupling methods to be simply and easily connected and calibrated.

BCI Probe &l Fixture 10kHz-230MHz

In Stock

IEC 61000-4-6 Accessory Package 

      • Frequency 10 kHz – 230 MHz
      • AC/DC: max. 125 V /1.5A
      • F-33-2 Current Probe ISO 17025 Calibration
      • AE/EUT: Sub-D15 connectors
      • Comes with Current Probe, Fixture, & Adapter
      • Free Technical Support & 2 Days Free Transit

The F120-9 A (F120 9) is a Fischer Custom Communications bulk current injection probe for testing products for immunity to conducted RF per IEC 61000-4-6. The F-120-9A has been designed to extend the use of conducted immunity testing over the bandwidth of 10 kHz – 230 MHz. The useable frequency range is 10 kHz - 230 MHz with an insertion loss of less than 8 dB between 150 kHz – 200 MHz. The input power rating is 100 watts for 30 minutes.

BCI Injection Probe

In Stock

Conducted RF Injection Probe Features 

      • Frequency 10 kHz – 230 MHz
      • AC/DC: max. 125 V /1.5A
      • F-33-2 Current Probe ISO 17025 Calibration
      • AE/EUT: Sub-D15 connectors
      • Part of IEC 61000-4-6 Accessory Package
      • Free Technical Support & 2 Days Free Transit

The F120-9 A (F120 9) is a Fischer Custom Communications bulk current injection probe for testing products for immunity to conducted RF per IEC 61000-4-6. The F-120-9A has been designed to extend the use of conducted immunity testing over the bandwidth of 10 kHz – 230 MHz. The useable frequency range is 10 kHz - 230 MHz with an insertion loss of less than 8 dB between 150 kHz – 200 MHz. The input power rating is 100 watts for 30 minutes.

Bulk Current Injection System

Conducted RF System Features

      • Conducted RF Bulk Current Injection (BCI) Equipment
      • Frequency of Injection Probe 10kHz-400MHz
      • Laptop & ISO 17025 Calibration Included
      • Signal generator 9 kHz - 1 GHz
      • 100 Built Watt Amplifier 9kHz-400MHz
      • Free Technical Support & 2 Days Free Transit
      • Turnkey Solution - Arrives Ready for Testing!

Overview

This turnkey system consists of the EM Test CWS 500N2, laptop, and associated bulk current injection accessories from Fisher Custom Communications based of the MIL-STD-461 CS114/ISO 11452-24 requirements. The EM Test system includes built in 100 watt amplifier, signal generator, power meter, and sensors. The entire system is designed for 10kHz-400MHz frequency range. Many of the active/measurement components come with ISO 17025 calibration included in rental price.