Com-Power LIT-930A - Rent 9kHz-30MHz Transient Limiters

Com-Power Voltage Spike Filter:

  • Frequency range: 9 kHz – 600 MHz
  • Typically Rented with LISN/AR or Analyzer 
  • 10 dB Attenuation (in-band) 
  • Band-Pass Filter to Attenuate Out-of-band Signals

Get weekly, two week, and monthly rentals on all products

Got Questions about the equipment? Get technical support

Two FREE days transit time with every rental

Request A Quote

Description

Overview

Transient Limiter Limits input voltage when conducted EMI emissions measurement are conducted using Line Impedance Stablization Network (LISN). The EMC receiver input is connected live and neutral line of the product via the LISN. The LISN blocks the supply voltage from LISN RF portt but allow the RF signal to pass without much attenuation, so that it can be measured with a EMC receiver. Because the RF signal must be passed through, any short transients (a few microseconds or less) on the power supply lines will also be passed through. Trasient limiter LIT-930A protects the EMI receiver input from these short transients A transient with high enough energy witll damage a unprotected receiver input.

Data Sheet

Specifications

Common Standards

CISPR 22 & FCC Part 15 

Frequency 

9 kHz to 30 MHz

Insertion Loss (in-band)

10 dB ±1 dB

Maximum Input Level

4 Watts Continuous (+36 dBm)

±15 Volts DC (without damage)

VSWR

1:1.02 (average), 1:1.2 (max)

Input/Output Connector

N-type (male) / N-type (female)

Dimensions (L x W x H) (not including cable/connectors

4" x 2.2" x 1.5" (102.7 mm x 55.6 mm x 37.5 mm)