Com-Power ISN/CDN-T8SE
Related Equipment
Description
The CDN-T8SE is used during conducted emissions or immunity tests on devices with signal/telecom ports intended for connection to shielded (or screened) lines with up to four balanced pairs. The EUT and AE ports of the CDN-T8SE are equipped with shielded RJ45 receptacles. The RF input/output port is located on the top side of the network, and is fi tted with a female BNCtype connector.
The outer surface of the network’s metallic enclosure is powder coated for durability, and is mounted onto an untreated (conductive), stainless steel base plate. The base plate extends beyond the footprint of the network enclosure at the front and back, providing convenient access to eff ectively ground the network, which is essential.
Any individual Com-Power CDN may be purchased separately, or as part of a CIS series conducted immunity test system. Test systems also include an ACS series power amplifi er, as well as the required accessories.
- Specifications:
- Line parameters:
- 4 pairs, balanced, shielded, 100 Ohm impedance
- Frequency Range
- 150 kHz to 30 MHz (as ISN)
- 150 kHz to 230 MHz (as CDN)
- Max Input Voltage
- 40 Vrms
- Application
- Screened lines w/up to 4 balanced pairs
- Current rating
- 1.5 Amps (max)
- Voltage rating
- 125 VAC (line to GND)
- RF Input Connector
- 50 Ohm BNC (female)
- EUT/AE Port Connections
- Shielded RJ45
- Common mode impedance
- 150 kHz to 30 MHz: 150Ohms +/- 20Ohms
- 30 MHz to 80 MHz:150Ohms +60Ohms / -45Ohms
- 80 MHz to 230 MHz: 50Ohms +/-60Ohms
- Voltage Division Factor
- 150 kHz to 30 MHz:10 dB +/-1 dB
- 30 MHz to 230 MHz: 10 dB +2 dB / -1 dB
- Decoupling Attenuation (Isolation)
- 150 kHz to 5 MHz: >70 dB
- 5 MHz to 30 MHz:>60 dB
- 30 MHz to 80 MHz:>50 dB
- 80 MHz to 230 MHz:>40 dB
- Dimensions
- 8.5 x 4.5 x 3.5 Inches (21.5 x 11.4 x 8.8 cm)