Com-Power LIT-930A - Rent 9kHz-30MHz Transient Limiters
Overview
Transient Limiter Limits input voltage when conducted EMI emissions measurement are conducted using Line Impedance Stablization Network (LISN). The EMC receiver input is connected live and neutral line of the product via the LISN. The LISN blocks the supply voltage from LISN RF portt but allow the RF signal to pass without much attenuation, so that it can be measured with a EMC receiver. Because the RF signal must be passed through, any short transients (a few microseconds or less) on the power supply lines will also be passed through. Trasient limiter LIT-930A protects the EMI receiver input from these short transients A transient with high enough energy witll damage a unprotected receiver input.
Specifications
Common Standards |
CISPR 22 & FCC Part 15 |
Frequency |
9 kHz to 30 MHz |
Insertion Loss (in-band) |
10 dB ±1 dB |
Maximum Input Level |
4 Watts Continuous (+36 dBm) ±15 Volts DC (without damage) |
VSWR |
1:1.02 (average), 1:1.2 (max) |
Input/Output Connector |
N-type (male) / N-type (female) |
Dimensions (L x W x H) (not including cable/connectors |
4" x 2.2" x 1.5" (102.7 mm x 55.6 mm x 37.5 mm) |