Fischer F-120-9A

Rent 230 MHz Current Injection Probe
  • Frequency Range 10 kHz - 230 MHz
  • Maximum Input Power 100 Watts
  • Typically Rent as Part of 230 MHz BCI Kit
  • Includes Calibration Fixture
Got Questions? Speak to an Expert +1 630-887-0329
Two FREE days transit with every rental

Description

The F-120-9A has been designed to extend the use of conducted immunity testing over the bandwidth of 10 kHz – 230 MHz. The useable frequency range is 10 kHz - 230 MHz with an insertion loss of less than 8 dB between 150 kHz – 200 MHz. The input power rating is 100 watts for 30 minutes.

Specifications:
Frequency
10 kHz to 400 MHz
Inner diameter:
40 mm
Outer diameter:
127 mm
Height:
70 mm
Input Power rating:
200 watts
Related Videos
Teseq NSG 4070 Test System Overview
Integrating External Amplifier Teseq NSG 4070