Rohde & Schwarz ENV216

Rent 50µH 16 Amp LISN
In Stock - Order by 3 p.m. ships today
  • Frequency Range 9 kHz to 30 MHz
  • 50µH V-network Max 16 Amps /240 VAC
  • Built-in Transient Limiter, Attenuator, & Filters 
  • Compliant Test Equipment to CISPR 16-1-2
  • Current ISO 17025 Accredited Calibration
Got Questions? Speak to an Expert +1 630-887-0329
Two FREE days transit with every rental

Description

The R&S®ENV216 two-line V-network meets the requirements of CISPR 16-1-2 and EN 55016-1-2 for V-networks with a simulated impedance of (50 µH + 5 Ω) || 50 Ω in the frequency range from 9 kHz to 30 MHz as well as the ANSI C63.4 in the frequency range from 150 kHz to 30 MHz. A female connector with protective earth contacts is provided for connecting the EUT.

Owing to its compact design and low weight, the R&S®ENV216 is ideal for frequently varying applications and especially for on-site disturbance voltage measurements on single-phase EUTs. Note that high leakage currents are produced because of the standard design of these V-networks. The networks should therefore be connected to a low-impedance protective earth system. In uncertain cases, an isolating transformer should be used.

In the case of AC supply operation in a range from 90 V to 240 V and 50 Hz to 60 Hz, the operating voltage for the built-in logic circuit is obtained from the AC supply direct. This covers all standard applications. If the EUT is operated with low AC voltages or DC voltages up to 50 V, the logic circuit is powered via an external plug-in power supply that is supplied as standard.

Specifications:
Simulated impedance
(50 uH + 5 Ohms) 50 Ohms
Frequency Range
9 kHz to 30 MHz
Error limits
20% +/- (magnitude), +/-11.5 degrees (phase), in line with CISPR 16-1-2
Isolation
9 kHz to 50 kHz -> 0 dB to 40 dB (increases linearly with logarithm of frequency)
50 kHz to 30 MHz -> 40 dB
Test path to EUT
AC supply voltage
0 V to 240 V AC + 10%
AC supply frequency
50 Hz to 60 Hz +/- 5%
DC voltage
0 V to 50 V DC
Test path to measuring receiver
Maximum permissible RF disturbance power from EUT
1 W
Highpass filter -�integrated, switch-selectable
150 kHz
Voltage division factor between EUT and measuring receiver port
built-in attenuator pad, calibration data supplied with V-network - 10dB
Response threshold of built-in pulse limiter
can be switched off -140 dB (uV)
Connectors
RF output
N female, 50 Ohms
Remote control input
25-contact, D-Sub, female
Input for artificial hand
4 mm connector, female, with knurled clamp
Reference ground
ground bar with three M4 threads
Protective earth
M6 threaded bolt
Dimensions
219 mm x 147 mm x 350 mm (8.6 in x 5.8 in x 13.8 in)
Related Videos
Rohde & Schwarz ENV4200 50µH 200 Amp LISN Overview