Rohde & Schwarz ENV216 - Rent 50µH 16Amp LISN

R&S ENV216 Two-Line LISN:

  • Frequency Range 9kHz to 30MHz
  • 50µH V-network up to 16Amps/240VAC
  • Built-in Transient Limiter, Attenuator, & Filters 
  • Compliant Test Equipment to CISPR 16-1-2
  • Current ISO 17025 Cal & 2 Days Free Transit Time

Options/Equipment


Get weekly, two week, and monthly rentals on all products

Got Questions about the equipment? Get technical support

Two FREE days transit time with every rental

Request A Quote

Rent Associated Emissions Equipment

Description

Overview

The R&S®ENV216 two-line V-network meets the requirements of CISPR 16-1-2 and EN 55016-1-2 for V-networks with a simulated impedance of (50 µH + 5 Ω) || 50 Ω in the frequency range from 9 kHz to 30 MHz as well as the ANSI C63.4 in the frequency range from 150 kHz to 30 MHz. A female connector with protective earth contacts is provided for connecting the EUT.

Owing to its compact design and low weight, the R&S®ENV216 is ideal for frequently varying applications and especially for on-site disturbance voltage measurements on single-phase EUTs. Note that high leakage currents are produced because of the standard design of these V-networks. The networks should therefore be connected to a low-impedance protective earth system. In uncertain cases, an isolating transformer should be used.

In the case of AC supply operation in a range from 90 V to 240 V and 50 Hz to 60 Hz, the operating voltage for the built-in logic circuit is obtained from the AC supply direct. This covers all standard applications. If the EUT is operated with low AC voltages or DC voltages up to 50 V, the logic circuit is powered via an external plug-in power supply that is supplied as standard.

Data Sheet

Specifications

Common Standards

CISPR 16-1-2

Simulated impedance

(50 µH + 5 Ω)||50 Ω

Frequency Range

9 kHz to 30 MHz

Error limits

±20% (magnitude), ±11.5° (phase), in line with CISPR 16-1-2

Isolation

9 kHz to 50 kHz - > 0 dB to 40 dB (increases linearly with logarithm of frequency)

50 kHz to 30 MHz - > 40 dB

Test path to EUT


AC supply voltage

0 V to 240 V AC + 10%

AC supply frequency

50 Hz to 60 Hz ± 5%

DC voltage

0 V to 50 V DC

Test path to measuring receiver


Maximum permissible RF disturbance power from EUT

1 W

Highpass filter - integrated, switch-selectable

150 kHz

Voltage division factor between EUT and measuring receiver port

built-in attenuator pad, calibration data supplied with V-network - 10dB

Response threshold of built-in pulse limiter

can be switched off - 140 dB (µV)

Connectors

RF output

N female, 50 Ω

Remote control input

25-contact, D-Sub, female

Input for artificial hand

4 mm connector, female, with knurled clamp

Reference ground

ground bar with three M4 threads

Protective earth

M6 threaded bolt

Dimensions

219 mm × 147 mm × 350 mm (8.6 in × 5.8 in × 13.8 in)