Solar 6220-1A
Description
The transformer is capable of handing up to 200 W of audio power into its primary over the frequency range 30 Hz to 250 kHz. The turns ratio provides a two-to-one step down to the special secondary winding. The secondary will handle up to 50 A of AC or DC without saturating the transformer.
Another secondary winding is connected to a pair of binding posts suitable for connecting to AC voltmeter as directed by the applicable EMI specifications. This winding serves to isolate the voltmeter from power ground. Neither the primary nor the secondary windings are connected to the end bells of the core. The transformer may be used as a 4 Ω primary and 1 Ω secondary or 2.4 Ω primary and 0.6 Ω secondary or 2 Ω primary and 0.5 Ω secondary.
- Specifications:
- Primary:
- Less than 5 ohms
- Secondary:
- 1/4 the primary impedance
- Audio power
- 200 W
- Dielectric test
- 600 VDC primary to secondary and each winding to end bells
- Secondary saturation:
- 50 A, AC or DC max.
- Turns ratio:
- 2-to-1 step down
- Secondary inductance:
- Approximately 1.3 mH (unloaded)
- Weight:
- 18 pounds
- Size:
- 11.43 cm x 13.33 cm x 15.87 cm