EM Test CDN M2/3 - Front Side
EM Test CDN M2/3 - Side
EM Test CDN M2/3 - Back

EM Test CDN M2/3

Rent CDN for 2/3 Supply Lines

In Stock & Ready To Ship
Orders by 3pm ship today

The EM Test CDN M2/3 provides switchable two- or three-line RF coupling for IEC 61000-4-6 immunity testing, supporting 250 volts, 16 amps, and frequencies between 150 kHz and 300 MHz.

Features

  • Frequency 150 kHz - 300 MHz
  • Max 250 Volts 16 Amps AC/DC
  • Designed for 2 or 3 Supply Lines
  • Includes Calibration Adapters
Up to 4 Free Days of Transit Time
Two transit days each way are excluded from rental period

Description

The EM Test CDN M2/3 is a switchable coupling decoupling network designed for conducted RF immunity testing on two- or three-line AC and DC power systems. It injects common mode disturbances onto supply conductors in accordance with IEC 61000-4-6. The network supports equipment operating at up to 250 volts and 16 amps, with a frequency range extending from 150 kHz to 300 MHz. Its selectable line configuration makes one CDN suitable for multiple power arrangements. Safety laboratory connectors simplify installation, while included calibration adapters support verification. The CDN provides repeatable RF coupling and protects auxiliary equipment from unwanted disturbance energy.

Technical Specifications:
M2/M3
For 2 or 3 AC/DC supply lines (switchable)
AE:
IEC 60320/C14 connector
EUT:
4mm safety lab connectors
AC/DC:
max. 250 V/16 A
Frequency:
150 kHz - 300 MHz
EM Test CDN Datasheet
Download

Video Library

Related Videos

Rent the EM Test CDN M2/3

Weekly, two-week and monthly rentals available.

Questions?630-887-0329

Compare conducted RF immunity test systems and injection equipment available for rent. Explore amplifiers, CDNs, clamps, and accessories based on frequency range, power, application, and test requirements.