GW Instek 5.6kW AC & DC Load:

  • 5600W Electronics Load with x2 Turbo Option
  • 56Amps 425VAC/600VDC Continuous Max
  • Positive or Negative Half-cycle Loading
  • Latop with Software Included with System 
  • Current Calibration & 2 Days Free Transit Time

Options/Equipment


Get weekly, two week, and monthly rentals on all products

Got Questions about the equipment? Get technical support

Two FREE days transit time with every rental

Request A Quote

Related Equipment

Description

GW Instek launches 20 models of the AEL-5000 series AC/DC electronic loads depending on the power range. The power range of a single unit is from 1875W to 22500W, and up to 8 units can be connected in parallel. The maximum power of single-phase parallel connection can reach 180kW, and the total power of 3-phase can reach 540kW, which are suitable for UPS, Inverter/Breaker, AC Power Source, Battery, Fuse/Breaker, DC Power Source and other applications.

The AEL-5000 series has built-in precision measurement circuits such as 16-bit A/D and DSP to provide accurate measurement items, which include voltage root mean square value (Vrms), current root mean square value (Arms), and watt value (Watt), volt-ampere (VA), crest factor (CF), power factor (PF), total harmonic distortion (THD), voltage total harmonic distortion (VTHD), current total harmonic distortion (ITHD) , peak current (Ipeak), maximum current (Amax), minimum current (Amin), maximum voltage (Vmax), minimum voltage (Vmin), time measurement. In addition, built-in test modes include UPS Efficiency, PV Inverter Efficiency, UPS Back-up time, Battery Discharge time, UPS transfer time, Fuse/Breaker Trip/Non-Trip, short circuit simulation, OCP, OPP and other test modes.

The AEL-5000 series has the Turbo mode (ON or OFF can be selected) design, which can increase the current and power of the electronic load by 2 times in one second. For test applications that require transient high power and large current such as transient overload test of protective components or short circuit of Fuse/Breaker and AC power supply, OCP and OPP tests etc.. The Turbo mode provides the most economical solution.

The AEL-5000 series also supports the Load On startup function (pre-set Load On). When the inverter or uninterruptible power supply is turned on, the series directly loads the set load current to verify that whether startup of the inverter or uninterrupted power supply connecting to the electrical appliance is stable. At the same time, the Load On start function can also set positive half cycle or negative half load to verify whether the output voltage of the inverter or uninterruptible power supply remains stable when the actual electrical appliance only has a positive half cycle or negative half cycle load current. Control load angle and unload angle can also be set (range 0~359 degrees) to verify the stability of the transient response of the inverter or uninterruptible power supply when the appliance is plugged in and unplugged. In addition, the series also supports SCR/TRIAC current phase modulation waveform, 90 degree Trailing Edge and Leading Edge settings.

For the application of the adjustable bandwidth (BW) function, when the bandwidth of the DUT does not match the bandwidth of the AEL-5000 series, there will be oscillations. Users can reduce the BW setting value accordingly to meet the response speed of the DUT. Inrush Current verifies whether the transient response of the inverter output voltage is stable when the electrical appliance is turned on (Inrush Current) and when the electrical appliance is suddenly connected (Surge Current).

The entire series of AEL-5000 provides over-voltage warning, over-current, over-power, and over-temperature protection. Analog Input terminal can control constant current, constant power and other working modes through external voltage. Vmonitor/Imonitor terminal is used to connect external voltage/current monitoring device. In addition, a variety of optional control interfaces are provided such as GPIB, RS-232, USB, and LAN to meet the needs of system integration.

AEL-5000 Brochure AEL-5000 Data SheetAEL-5000 User Manual

Specifications

Total Power 

5600 Watts

Current(Ampere)

56 Arms / 168Apeak

Voltage(Volt)

50~425Vrms / 600Vdc

FREQUENCY Range

DC,40~440Hz(CC,CP Mode) 

DC~440Hz(LIN,CR,CV Mode)

Protections 

 Over Power, Current, Voltage, & Temperature

Constant Current Mode for Sine-Wave

 0~56A

Resolution

1mA/16bits

Accuracy

±( 0.1% of setting + 0.2% of range )@ 50/60Hz

Linear Constant Current Mode for Sine-Wave, Square-Wave or Quasi-Square Wave, PWM Wave

0~56A

Resolution

1mA/16bits

Accuracy

±( 0.1% of setting + 0.2% of range )@ 50/60Hz

Constant Resistance Mode Range

1 ohm~20K ohm

Resolution*1

0.016666mS/16bits

Accuracy

±0.2% of (setting + range)@ 50/60Hz

Constant Voltage Mode

50~425Vrms / 600Vdc

Resolution

0.1V

Constant Power Mode

5600W

Resolution

0.1W

VOLTAGE READBACK A METER


Range & Resolution

600V & 0.01V

Parameters

Vrms,V Max/Min,+/-Vpk

CURRENT READBACK A METER


Range & Resolution

I28Arms/56Arms & 0.6mA/1.2mA

Parameters

Irms,I Max/Min,+/-Ipk

WATT READBACK W METER


Range & Resolution

5600W & 0.1W

Parameters

Vrms×Arms Correspond To Vrms and Arms