Rohde & Schwarz ENV216 Front Side
Rohde & Schwarz ENV216 front
Rohde & Schwarz ENV216 - 50H LISN Video Overview
Rohde & Schwarz ENV216 Back
Rohde & Schwarz ENV216 Front Side Above

Rohde & Schwarz ENV216

Rent 50µH 16 Amp LISN

The Rohde & Schwarz ENV216 is a two-line V-network LISN rated up to 16 A and 250 V AC, providing standardized impedance and RF coupling for CISPR conducted emissions testing.

Features

  • Frequency Range 9 kHz to 30 MHz
  • 50µH V-network Max 16 Amps /240 VAC
  • Built-in Transient Limiter, Attenuator, & Filters 
  • Compliant Test Equipment to CISPR 16-1-2
  • Current ISO 17025 Accredited Calibration
Order Type
Up to 4 Free Days of Transit Time
Two transit days each way are excluded from rental period
  • ENV216 serial number
  • DC charger p/n TRG30R120-74E03 VI
  • 4 adapters
  • Printed Manual
  • Calibration Certificate
  • Pelican Shipping Case
  • Can't find something? Contact Us

Description

The R&S®ENV216 two-line V-network meets the requirements of CISPR 16-1-2 and EN 55016-1-2 for V-networks with a simulated impedance of (50 µH + 5 Ω) || 50 Ω in the frequency range from 9 kHz to 30 MHz as well as the ANSI C63.4 in the frequency range from 150 kHz to 30 MHz. A female connector with protective earth contacts is provided for connecting the EUT.

Owing to its compact design and low weight, the R&S®ENV216 is ideal for frequently varying applications and especially for on-site disturbance voltage measurements on single-phase EUTs. Note that high leakage currents are produced because of the standard design of these V-networks. The networks should therefore be connected to a low-impedance protective earth system. In uncertain cases, an isolating transformer should be used.

In the case of AC supply operation in a range from 90 V to 240 V and 50 Hz to 60 Hz, the operating voltage for the built-in logic circuit is obtained from the AC supply direct. This covers all standard applications. If the EUT is operated with low AC voltages or DC voltages up to 50 V, the logic circuit is powered via an external plug-in power supply that is supplied as standard.

Specifications:
Simulated impedance
(50 uH + 5 Ohms) 50 Ohms
Frequency Range
9 kHz to 30 MHz
Error limits
20% +/- (magnitude), +/-11.5 degrees (phase), in line with CISPR 16-1-2
Isolation
9 kHz to 50 kHz -> 0 dB to 40 dB (increases linearly with logarithm of frequency)
50 kHz to 30 MHz -> 40 dB
Test path to EUT
AC supply voltage
0 V to 240 V AC + 10%
AC supply frequency
50 Hz to 60 Hz +/- 5%
DC voltage
0 V to 50 V DC
Test path to measuring receiver
Maximum permissible RF disturbance power from EUT
1 W
Highpass filter -�integrated, switch-selectable
150 kHz
Voltage division factor between EUT and measuring receiver port
built-in attenuator pad, calibration data supplied with V-network - 10dB
Response threshold of built-in pulse limiter
can be switched off -140 dB (uV)
Connectors
RF output
N female, 50 Ohms
Remote control input
25-contact, D-Sub, female
Input for artificial hand
4 mm connector, female, with knurled clamp
Reference ground
ground bar with three M4 threads
Protective earth
M6 threaded bolt
Dimensions
219 mm x 147 mm x 350 mm (8.6 in x 5.8 in x 13.8 in)
Rohde & Schwarz ENV216 Datasheet
Download
Rohde & Schwarz ENV216 User Manual
Download

Video Library

Video Guides
Related Videos

FAQs

The ENV216 operates from 9 kHz to 30 MHz. This range covers the conducted emissions frequencies specified by many commercial, industrial, military, and product standards. For ANSI C63.4 and FCC measurements, it supports the commonly tested range of 150 kHz to 30 MHz.

The ENV216 provides a simulated impedance of (50 µH + 5 Ω) in parallel with 50 Ω. This network impedance meets the requirements established for conducted disturbance-voltage measurements. Maintaining standardized impedance helps produce repeatable results between different laboratories and test configurations.

Yes. The ENV216 includes a switchable pulse limiter that helps protect the connected EMI receiver or spectrum analyzer from high-energy RF interference pulses. The limiter should generally remain enabled unless the test procedure or measurement configuration requires otherwise.

Yes. As a two-line V-network, the ENV216 allows disturbance voltages to be measured separately on the line and neutral conductors. The selected conductor can be changed manually or remotely when connected to compatible equipment. Testing both conductors helps identify the highest emissions produced by the EUT.

Rent the Rohde & Schwarz ENV216

Weekly, two-week and monthly rentals available.

Questions?630-887-0329