Description
Coupling Decoupling Network for IEC 61000-4-6, type M5, 100 A, 150 kHz-80 MHz (terminal block), 3x L, N, PE with calibration adapter set in storage case, includes 2x CAL U100M, SAR MA51M, SAR M500M, SAR M116, A 50-N
Data SheetSpecifications:
Frequency Range |
150 kHz to 80 MHz |
No. of Lines |
5 |
Maximum AC Power |
520 Volts (line to line) |
Maximum DC Power |
600 Volts (line to line) |
Current max.: |
100 Amps (maximum one hour) |
Test voltage: |
3.1 kVDC, 2 sec |
Common mode impedance (EUT port) 150 kHz to 24 MHz: |
150 Ω ±20 Ω |
24 MHz to 80 MHz: |
150 Ω +60 Ω / -45 Ω |
Coupling path (In / Out port / EUT) |
|
Connection: |
BNC 50 Ω |
RF voltage: |
<30 V, refers to 50 V test level in 300 Ω |
Voltage division factor (RF input to EUT port) |
|
150 kHz to 24 MHz: |
10 dB ±1 dB |
24 MHz to 80 MHz: |
for M2 and M3: 10 dB ±1 dB for M4 and M5: 10 dB +2 / -1 dB |
Insertion loss (EUT / AE) f < 400 Hz: |
<0.1 dB |
Decoupling of CM disturbance (RF port / AE) typ |
|
150 kHz: |
>20 dB |
1.5 MHz: |
>50 dB |
30 MHz: |
>40 dB |
80 MHz: |
>20 dB |