Teseq CDN M5-100S - Rent 3-Phase 100Amp RF CDN

EM Test RF Power CDN: 

  • Designed for 5 Power Lines, (3L+N+PE)
  • Max 100Amps 520 Volts AC & 600 Volts DC
  • Frequency Range 150 kHz - 80 MHz
  • Includes Calibration Adapters

Get weekly, two week, and monthly rentals on all products

Got Questions about the equipment? Get technical support

Two FREE days transit time with every rental

Request A Quote

Related RF CDNs

Description

Coupling Decoupling Network for IEC 61000-4-6, type M5, 100 A, 150 kHz-80 MHz (terminal block), 3x L, N, PE with calibration adapter set in storage case, includes 2x CAL U100M, SAR MA51M, SAR M500M, SAR M116, A 50-N

Data Sheet

Specifications:

Frequency Range

150 kHz to 80 MHz

No. of Lines

5

Maximum AC Power

520 Volts (line to line) 


Maximum DC Power

600 Volts (line to line) 

Current max.:

100 Amps (maximum one hour)

Test voltage:

3.1 kVDC, 2 sec

Common mode impedance (EUT port)

150 kHz to 24 MHz:

150 Ω ±20 Ω


24 MHz to 80 MHz:

150 Ω +60 Ω / -45 Ω

Coupling path (In / Out port / EUT)


Connection:

BNC 50 Ω

RF voltage:

<30 V, refers to 50 V test level in 300 Ω

Voltage division factor (RF input to EUT port)

150 kHz to 24 MHz:

10 dB ±1 dB

24 MHz to 80 MHz:

for M2 and M3: 10 dB ±1 dB

for M4 and M5: 10 dB +2 / -1 dB

Insertion loss (EUT / AE) f < 400 Hz:

<0.1 dB

Decoupling of CM disturbance (RF port / AE) typ


150 kHz:

>20 dB

1.5 MHz:

>50 dB

30 MHz:

>40 dB

80 MHz:

>20 dB