NSG 3040 Video & Overview
Teseq NSG 3040 Generator
This video guide shows how to setup the EM Test LD 200N load dump generator, including connections to front and back of unit, as well as controlling and modifying pulses via the iso.conrol software.
System Overview
Overview
The Teseq NSG 3040 electromagnetic immunity (EMI) test generator provides 4.4kV Surge and 4.4kV electrical fast transient (EFT) with a built-in single phase coupler and is designed primarily for cable-borne transient interference tests. A2LA accredited calibration is included in the EMC rental equipment price. This Teseq products modular architecture and industry standard interfaces allow it to be easily expanded and customized to meet individual testing needs.
This Immunity Test Generator is designed to fulfill conducted EMC testing requirements for CE mark testing, including Combination Wave Surge (4.4 kV), Electrical Fast Transient (EFT) pulses (4.8 kV) and Power Quality Testing (PQT). The NSG3040 includes a 7" color screen and easy to manage user-interface allowing for easy adjustments with the thumb-wheel. This EMC test equipment can also be controlled via PC through the Ethernet Port.
This Teseq (previously known as Schaffner) surge/immunity generator is an all in one box that tests to EN/IEC 61000-4-4, EN/IEC 61000-4-5 and EN/IEC 61000-4-11 and CE Mark with optional INA 6502. Expansion capabilities enable the system to be configured for a much broader range of applications including Telecom Surge 10/700 and Magnetic Field tests. This pulse generator, similar to the NSG 3060, provides the same easy to use interface and connection methods.
Specifications
Common Standards |
EN/IEC 61000-4-4, EN/IEC 61000-4-5, EN/IEC 61000-4-11, & CE Mark |
Integrated CDN |
|
AC Voltage |
24-260 Vrms, 50/60 Hz (phase-neutral), 400 Hz max |
AC Current |
16 Amps, Max 25 Amps for 15 min. |
DC Voltage |
0-260 VDC, Max |
DC Current |
16 Arms, Max 25Arms for 15 min. |
EFT Burst 5/50ns: |
|
Standards |
IEC 61000-4-4, EN 61000-4-4, CE Mark |
Voltage Waveform into 50Ω load |
5ns Rise Time ±1.5ns, 50µs pulse width ±15ns |
Voltage Waveform into 1000Ω load |
5ns Rise Time ± 1.5ns, 50µs pulse width ± 100/-15ns |
Voltage Amplitude |
± 100V – 2.4kV into 50Ω, ±200V – 4.8kV into 1000Ω |
Burst Duration |
1µ to 1999 s, single pulse and continuous |
Burst Period |
1 ms to 4200 s |
Frequency |
100 Hz to 1000 kHz |
Combination Wave Surge: |
|
Standards |
IEC 61000-4-5 ed. 3, EN 61000-4-5, ANSI C62.41.2 Cat A& B, UL 1449 ed. 3 sec. 37, ANSI C62.45 |
Open Circuit Voltage Waveform |
1.2µs Front Time ± 30%, 50µs Duration ± 20% |
Short Circuit Current Waveform |
8µ Front Time ± 20%, 20µs Duration ± 20% |
Peak Open Circuit Voltage |
±200V–4.4kV in 1 V step |
Peak Short Circuit Current |
±100A–2.2kA |
Pulse Repetition Rate |
10 s, up to 600 s |
Weight |
25 kilograms, 55 pounds |
Dimensions |
45x22x56 cm, 18x9x22 inches |
CDNs
Rent coupler decoupler networks (CDN)s from a preferred rental partner of Ametek CTS.
Take advantage of A2LA ISO 17025 calibrations and fast deliveries!
Rental Couplers NSG 3040:
Coupler | Capabilities |
CDN 3061 | Single phase 270 V / 16 A automatic coupling decoupling network |
CDN 3063 |
Three phase 480 V / 32 A automatic coupling decoupling networks |
CDN 3083S-100 |
Manual 3-phase coupler for Surge (8 kV) only (combination and ring wave) with EUT current up to 100 A / 200 A |
CDN 3083B-100 | Manual 3-phase coupler for EFT / Burst (8 kV) only with EUT supply up to 690 VAC (1000 VDC) / 100 A |
Coupling network for 2 kV surge pulse 1.2 / 50 μs IEC/EN 61000-4-5 on unshielded symmetrical high speed telecom lines (Ethernet) |
|
CNV504N1.3 |
4kV coupler/decoupler for Surge & Ringwave on 4 data lines |
CDN 3425 |
Teseq Burst/EFT couple pulses to data lines. |
CM.CCL |
Capacitive coupling clamp by Thermo-Keytek is designed for EFT pulses on I/O lines or data lines |
All Accessories
Rent coupler decoupler networks (CDN)s from a preferred rental partner of Ametek CTS.
Take advantage of A2LA ISO 17025 calibrations and fast deliveries!
NSG 3040 Full Accessory List
Item | Capabilities |
CDN 3061 | Single phase 270 V / 16 A automatic coupling decoupling network |
CDN 3063 |
Three phase 480 V / 32 A automatic coupling decoupling networks |
CDN 3083S-100 |
Manual 3-phase coupler for Surge (8 kV) only (combination and ring wave) with EUT current up to 100 A / 200 A |
CDN 3083B-100 | Manual 3-phase coupler for EFT / Burst (8 kV) only with EUT supply up to 690 VAC (1000 VDC) / 100 A |
Coupling network for 2 kV surge pulse 1.2 / 50 μs IEC/EN 61000-4-5 on unshielded symmetrical high speed telecom lines (Ethernet) |
|
CNV504N1.3 |
4kV coupler/decoupler for Surge & Ringwave on 4 data lines |
CDN 3425 |
Teseq Burst/EFT couple pulses to data lines. |
CM.CCL |
Capacitive coupling clamp by Thermo-Keytek is designed for EFT pulses on I/O lines or data lines |
CDN 8014/8015 |
Capacitive coupling clamp for burst |
CDN 163 |
Burst coupling network 100 A per phase (coupling all to ref ground) |
CDN 117/118 |
Coupling networks for signal-/data lines (surge) |
CAS 3025 |
Burst/EFT verifi cation set |
MD 200 |
Voltage differential probe 7 kV |
MD 300 |
Current probe 5 kA |
MD 200A |
Voltage differential probe 7 kV |
MD 300 |
Current probe 5 kA |
INA 165 |
Conducted stand-off |
INA 166 |
Brackets 5 HU for rack mounting |
INA 6501 |
Manual step transformer, 16 AAC, 0/40/70/80% |
INA 6502 |
Automatic step transformer, 16 AAC, 0/40/70/80% |
VAR 6501 |
Automatic variable transformer, 7.5 A |
VAR 6502 |
Automatic variable transformer, 2 x 16 A |
VAR 6503 |
Manual variable transformer, 7.5 A |
MFO 6501 |
Manual magnetic fi eld option -4-8 |
MFO 6502 |
Automatic magnetic fi eld option -4-8 |